![Motrona IT251 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/motrona/it251/it251_operating-manual_1839559013.webp)
It251_02c_oi_e.doc / Apr-16
Page 13 / 16
7.3.
Setting of the division rate of the index divider
These settings use the same rules and codes as shown with the main divider (see section 6)
Index Divider [Z]
DIL3
on = log.0, off = log.1
Binary value
8
7
6
5
4
3
2
1
128
64
32
16
8
4
2
1
on on on on on on on on
1 : 1
on on on on on on on off
1 : 2
on on on on on on off on
1 : 3
on on on on on on off off
1 : 4
off off off off off off on on
1 : 253
off off off off off off on off
1 : 254
off off off off off off off on
1 : 255
off off off off off off off off
1 : 256
7.4.
Position and width of the index pulse
For illustration of the functions, the drawings of this chapter assume that the main impulse
divider of the A/B input pulses would be set to 8. The index pulse will appear at the output
according to the division rate set (see section 7.3 above).
DIL2
Small index pulse (1/4 of the input period time)
6
5