GV20401a_e.doc / Sep-08
Page 7 / 10
5.
Impulse Inputs
The input impulses must be applied to the 9-position Sub-D-connector marked “Input”
(male connector on unit site). The pin assignment is shown in the block diagram and is also
printed to the top side of the unit.
The 6-position DIL switch on top of the unit provides setting of the desired input characteristics.
With most of all practical applications one of the following two configurations will be suitable:
Switch Setting
Acceptable
Signal Levels
Required
Input Signals
Aux. Output Pin 4
(Encoder Supply)
ON
1 2 3 4 5 6
RS422 (Diff.>1V)
TTL (5 V)
HTL (10 - 30 V)
Differential signals
A, /A , B, /B, Z, /Z
(inverted signals are "must")
+5,4 V
(respectively V
ext.
*)
ON
1 2 3 4 5 6
HTL (10 - 30 V)
Single-ended signals
A, B, Z
(no inverted signals required)
+V
B
- 1,4 V
(respectively V
ext.
**)
Other switch positions than shown above are reserved for special applications and must only
be used upon advice of motrona.
*)
Where for encoder supply a voltage higher than 5.4 volts should be required, please apply an
appropriate voltage to teVext.
**)
Where for encoder supply a voltage higher than +V
B
should be required, please apply an
appropriate voltage to teVext.