background image

GV20401a_e.doc / Sep-08 

 

Page 6 / 10 

4.

 

Power Supply 

4.1.

 

Supply from an unstabilized 10 - 30 volts DC source 

In general, the unit is supplied with an unstabilised DC voltage of 10 - 30 V, using the screw 
terV

B

 and GND. In this case pin 4 of the input Sub-D-connector will also provide a +5 V 

auxiliary output for encoder supply (max. 150mA). 
 

4.2.

 

Supply from a stab5 volts DC source 

The unit accepts also stabilized supply from a +5 V source (e.g. when the input comes from the 

encoder simulation of a drive which is also intended to supply the splitter). In this case,  
Pin 4 (+5 V) and Pin 5 (GND) of the 9-position input connector are suitable to apply power. 
 

 

Units supplied with 5 volts only are unable to generate output levels higher than 
5 volts, unless a corresponding voltage is applied to screw teVext.  

 

The screw terminal marked "Shield" connects the metallic housings of the Sub-D-connectors 
only. Depending on individual needs for earthing and screening, it can remain unconnected or 
tied to earth or to unit GND. 

 
 

 

 

For technical reasons no reverse polarity protection is available when the 
unit is supplied with +5 volts only. Wrong polarity misconnection of the  
5 volts power may cause serious damage to the unit. 

 

 

Screw terminal "+V

ext" 

and pin 4 of the 9-position input connector are 

galvanically connected inside the unit. It is therefore not allowed to apply 

different potentials to these two positions 

 

Содержание GV204

Страница 1: ...S422 or TTL differential signals or with HTL signals differential or single ended Two encoder outputs A A B B Z Z each with individually programmable output levels TTL 5 V or HTL 10 30 V Max frequency 750 kHz TTL or 300 kHz HTL Power supply either 5 V DC or 10 30 V DC Aux voltage output 5 V for encoder supply with 10 3 0V power supply Operating Instructions ...

Страница 2: ...t is a must to observe all general and also all country specific and application specific safety standards When this unit is used with applications where failure or maloperation could cause damage to a machine or hazard to the operating staff it is indispensable to meet effective precautions in order to avoid such consequences Regarding installation wiring environmental conditions screening of cab...

Страница 3: ...bility Hint 4 2 Application 5 3 Block Diagram 5 4 Power Supply 6 4 1 Supply from an unstabilized 10 30 volts DC source 6 4 2 Supply from a stabilized 5 volts DC source 6 5 Impulse Inputs 7 6 Impulse Outputs and Output Levels 8 7 Dimensions 9 8 Specifications 10 ...

Страница 4: ...lly compatible to the previous models with all functions connections dimensions and technical specifications Merely the successor model provides an additional DIL switch to set the input format to either TTL or HTL level which allows to replace both parent models by just one new model Moreover GV204 provides a few technical upgrades e g higher frequencies resulting in increased quality without aff...

Страница 5: ...signals with HTL level When all signals A A B B Z Z are available GV 204 will accept all industrial impulse formats and levels like RS422 TTL differential HTL differential The outputs provide all signals A A B B Z Z even when the inverted signals are not available on the input site The output signal level is individually selectable to 5 volts or to 10 30 volts by corresponding DIL switch setting 3...

Страница 6: ...ition input connector are suitable to apply power Units supplied with 5 volts only are unable to generate output levels higher than 5 volts unless a corresponding voltage is applied to screw terminal Vext The screw terminal marked Shield connects the metallic housings of the Sub D connectors only Depending on individual needs for earthing and screening it can remain unconnected or tied to earth or...

Страница 7: ...gnal Levels Required Input Signals Aux Output Pin 4 Encoder Supply ON 1 2 3 4 5 6 RS422 Diff 1V TTL 5 V HTL 10 30 V Differential signals A A B B Z Z inverted signals are must 5 4 V respectively Vext ON 1 2 3 4 5 6 HTL 10 30 V Single ended signals A B Z no inverted signals required VB 1 4 V respectively Vext Other switch positions than shown above are reserved for special applications and must only...

Страница 8: ...ted signals will be available at the output even when no inverted signals appear at the input OUT1 TTL OUT1 HTL OUT2 TTL OUT2 HTL 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON With output format TTL the output level is always 5 volts With output format HTL the output level approximately corresponds to the supply voltage VB When terminal Vext receives a voltage higher than the power supply VB the out...

Страница 9: ...GV20401a_e doc Sep 08 Page 9 10 7 Dimensions 23456 85 3 346 90 3 543 38 1 496 50 1 969 1234 1 ...

Страница 10: ...TL differential 300 kHz HTL Inputs Symmetric differential inputs A A B B Z Z RS422 or TTL level or HTL 10 30 V level Asymmetric single ended inputs A B Z HTL level 10 30 V Outputs 2 x A A B B Z Z selectable 5 V TTL or 10 30 V HTL push pull max 30 mA Propagation delay 700 ns Ambient temperature Operation 0 45 C 32 113 F Storage 25 70 C 13 158 F Weight Approx 120 g Conformity and standards EMC 89 33...