Motrona GV 470 Скачать руководство пользователя страница 5

GV47001b_e.doc / Feb-08 

 

Page 5 / 9 

2.

 

Electrical Connections and LEDs 

2.1.

 

Power Supply and LED Assignment 

The unit provides a 3-position screw terminal strip for supply from a 10 – 30 volts DC power 
unit. The current consumption is approx. 100 mA (no-load operation).  

The “Select” input terminal provides selection of the desired source encoder. Details will be 
described later. 

 

 
 

 

 

The upper LED (green) signals that power is applied to the unit. 

 

The lower LEDs (yellow, red, orange) signal the actual logical states of the input channels A, B 
and Z. With very low input frequencies it is possible to visually check the input pulses, the 

phase displacement A/B and the index pulse function of an encoder. 

 

2.2.

 

Encoder Input 

The signal to be distributed to the outputs must be applied to the 8-position input terminal. The 

appropriate input level (RS422 or HTL 10-30 V) must be set to the DIL switches correspondingly. 

 

With RS422 setting, and also with HTL setting and impulse levels lower than 15 volts, the unit 
needs at any time the non-inverted and the inverted input signals (differential input).  

 
With HTL levels higher than 15 volts you are free to either use the inverted inputs or to just 
leave them unconnected (the unit will accept differential and single-ended operation as well 

with input levels >15 volts). 
 
Other input characteristics like TTL-single-ended inputs or Namur signals are possible as well, 

but may need additional remote circuit at the input terminals. 

 

Where the potential-separation between input and outputs is required, the input encoder must 
be supplied from a remote power source. 

 

The DIL switch allows to connect the unit’s internal power supply (approx. 5.3 volts) to the 
terminals „0“ und „+5“ for use as an auxiliary encoder supply. However, this will switch off the 

potential separation and tie the encoder potential to the general GND. 

 

 
Input terminal strip: 
 

 

A codification of the input connector avoids accidentally mix-up with other connectors. 

- +

Se lect

1   2   3

ON

A

B

Z

0 +5 A /A B /B Z / Z

1   2   3   4   5   6   7   8

Содержание GV 470

Страница 1: ...r input RS422 or HTL 10 30V Cascading output Cascading input 8 output channels each A A B B Z Z potential separated from input each with individual output level Power supply 10 30 VDC LEDs for display...

Страница 2: ...l and also all country specific and application specific safety standards When this unit is used with applications where failure or maloperation could cause damage to a machine or hazard to the operat...

Страница 3: ...nd Block Diagram 4 2 Electrical Connections and LEDs 5 2 1 Power Supply and LED Assignment 5 2 2 Encoder Input 5 2 3 Outputs 6 2 4 Cascading of Several Units and Encoder Select Function 6 3 Input Sett...

Страница 4: ...ls and with potential separation to the input signals Separate cascading inputs and outputs provide cascading of several units to totally n x 8 output channels without loss of regular output terminals...

Страница 5: ...RS422 setting and also with HTL setting and impulse levels lower than 15 volts the unit needs at any time the non inverted and the inverted input signals differential input With HTL levels higher tha...

Страница 6: ...ted to any individual voltage from 5 5 to 30 volts allowing individual level assignment to any of the 8 outputs Output terminal strip All output connectors use the same connector codification and may...

Страница 7: ...0 30 volts outputs refer to the encoder input of the preceding unit It is possible at any time to switch over from one to the other source encoder during operation therefore cascaded units can also op...

Страница 8: ...ut connector OFF potential separation is active no aux output voltage is available on the terminals ON potential separation is switched off aux output voltage for encoder supply is available When swit...

Страница 9: ...symmetric HTL operation 10 30 volts difference approx 10 volts Input level with asymmetric HTL operation single ended without inverted signal High 15 volts Low 10 volts Outputs Push Pull 3 5 30 volts...

Отзывы: