1.

 

Introduction and Block Diagram 

GV 470 has been designed to distribute the impulse signals of an incremental encoder or 
measuring system to up to eight target units.  

 

The encoder input is switch-selectable for operation with either standard RS422 signals or with 
HTL (24 V) signals, with differential (symmetric) or single-ended (asymmetric) characteristics. 

 

All eight output channels provide push-pull characteristics with individually adjustable output 
levels, and with potential separation to the input signals. 

 

Separate cascading inputs and outputs provide cascading of several units to totally n x 8 output 
channels without loss of regular output terminals. Furthermore, cascaded configurations allow 

remote selection and switch-over between several input encoders. 

 

GV 470 is built into a most compact and space-saving housing for mounting on DIN rails. 
 

 
The following drawing explains the principle of function with one of the eight output channels: 
 

1

2

3

5VDC

24VDC

5VDC

1

2

3

4

5

6

7

8

3

1

2

3

4

5

6

7

8

INPUT

OUTPUTS

1 - 8

8

7

2

1

4

5

6

5VDC

Lev el

RS422 1 - 6  on

H TL

1 - 6  off

A

/A

B

/B

Z

/Z

(   8 x  )

OPTO

Isolation

DIL Swi tch

GND int.

Select

A

/A

B

/B

Z

/Z

 

Содержание GV 470

Страница 1: ...r input RS422 or HTL 10 30V Cascading output Cascading input 8 output channels each A A B B Z Z potential separated from input each with individual output level Power supply 10 30 VDC LEDs for display...

Страница 2: ...l and also all country specific and application specific safety standards When this unit is used with applications where failure or maloperation could cause damage to a machine or hazard to the operat...

Страница 3: ...nd Block Diagram 4 2 Electrical Connections and LEDs 5 2 1 Power Supply and LED Assignment 5 2 2 Encoder Input 5 2 3 Outputs 6 2 4 Cascading of Several Units and Encoder Select Function 6 3 Input Sett...

Страница 4: ...ls and with potential separation to the input signals Separate cascading inputs and outputs provide cascading of several units to totally n x 8 output channels without loss of regular output terminals...

Страница 5: ...RS422 setting and also with HTL setting and impulse levels lower than 15 volts the unit needs at any time the non inverted and the inverted input signals differential input With HTL levels higher tha...

Страница 6: ...ted to any individual voltage from 5 5 to 30 volts allowing individual level assignment to any of the 8 outputs Output terminal strip All output connectors use the same connector codification and may...

Страница 7: ...0 30 volts outputs refer to the encoder input of the preceding unit It is possible at any time to switch over from one to the other source encoder during operation therefore cascaded units can also op...

Страница 8: ...ut connector OFF potential separation is active no aux output voltage is available on the terminals ON potential separation is switched off aux output voltage for encoder supply is available When swit...

Страница 9: ...symmetric HTL operation 10 30 volts difference approx 10 volts Input level with asymmetric HTL operation single ended without inverted signal High 15 volts Low 10 volts Outputs Push Pull 3 5 30 volts...