MAINTAINED ACTION
6 ON
The opening or closing command (see
page 24), will have effect only by keeping
the button pressed. Once released, the
movement stops.
Also, this function excludes use of the
transmitter.
REOPENING
7 OFF
When detecting an obstacle during closing,
the photocells trigger the gate to reopen
(see page 26).
If there are no photocells or other safety devi-
ces connected, leave the dip switches ON.
TEMPORARY STOP
8 OFF
When detecting an obstacle during move-
ment, the photocells trigger the gate to stop
(see page 26).
If there are no photocells or other safety devi-
ces connected, leave the dip switches ON.
Press the button or use the transmitter for
the gate to move again. If you have also
selected automatic closing (dip switch 1
ON), the gate will reclose once the set time
interval has elapsed.
PHOTOCELLS TEST
9 ON
At each opening or closing command,
whether from button or transmitter, the control
panel will check the effi ciency of the photo-
cells before initiating any action.
Dip switch 10 not in use:
Keep it in the OFF position!
OBSTACLE DETECTION
5 ON
Even when gate is closed, open or closed due
to a Total Stop (from button connected on St-
G), if the safety devices (i.e. the photocells)
detect an obstacle, this function blocks any
command.
PRE-FLASHING
4 ON
The (Lumistar) fl ashing light connected on
20-K1, fl ashes 5 seconds before allowing
any opening or closing action.
yes
no
yes
no
yes
no
yes
no
yes
no
yes
no