2012 MotorVac, Inc.
13
Service Procedure With Manifold Connection
1. Open both ball valves on manifold assembly. The system is now in bypass.
2. Connect the CarbonClean 1000 supply hose to the manifold.
3. Start vehicle and inspect for any leaks at the manifold connections.
4. Note the vehicle fuel line pressure as indicated on the fuel line pressure gauge
as it is required to set the machine pressure for the service. Carbon Clean 1000
diagnostic features can now be used to evaluate fuel system performance if
desired. See diagnostic section 5 of this manual.
5. Run the vehicle between 1700 and 2000 rpm to warm up the engine and catalytic
converter to normal operating temperature.
Содержание CarbonClean 1000
Страница 1: ...2012 MotorVac Inc ZIM11 00474 Rev 0 CarbonClean1000...
Страница 2: ......