Rating Table

Minimum current ratings based on typical rated operation currents of motors for the 
corresponding rated operational powers 
Current rating optimized for kW@600V & hp@550-600V - Ref IEC 60947-4-1 Table G.1 where 
applicable. 

Size 1,2 and 3 

Type 

I

e

 

kW 

1)

 

 FLA 

Hp 

2)

 

U

s

 

3)

  230V  400V  500V  A 

3)

  200V  208V 

220-

240V 

440-

480V 

550-

600V 

VMX-SGY-I-17-6-01 

17 

7.5 

7.5 

17 

10 

15 

VMX-SGY-I-22-6-01 

22 

5.5 

11 

11 

22 

15 

20 

VMX-SGY-I-29-6-01 

29 

7.5 

15 

15 

27 

7.5 

7.5 

7.5 

20 

25 

VMX-SGY-I-35-6-01 

35 

7.5 

18.5 

22 

34 

10 

10 

10 

25 

30 

VMX-SGY-I-41-6-01 

41 

11 

22 

22 

41 

10 

10 

10 

30 

40 

24VDC,

 

VMX-SGY-I-55-6-01 

55 

15 

30 

37 

52 

15 

15 

15 

40 

50 

110VAC 

VMX-SGY-I-66-6-01 

66 

18.5 

37 

45 

65 

20 

20 

20 

50 

60 

to 

VMX-SGY-I-80-6-01 

80 

22 

45 

55 

77 

20 

25 

25 

60 

75 

230VAC

 

VMX-SGY-I-100-6-01 

100 

30 

55 

55 

99 

30 

30 

30 

75 

100 

VMX-SGY-I-132-6-01 

132 

37 

75 

90 

125 

40 

40 

40 

100 

125 

VMX-SGY-I-160-6-01 

160 

45 

90 

110  156 

50 

50 

60 

125 

150 

VMX-SGY-I-195-6-01 

195 

55 

110 

132  192 

60 

60 

75 

150 

200 

VMX-SGY-I-242-6-01 

242 

75 

132 

160  242 

75 

75 

75 

200 

250 

VMX-SGY-I-302-6-01 

302 

90 

160 

200  302  100  100 

100 

250 

300 

VMX-SGY-I-361-6-01 

361  110 

200 

250  361  125  125 

150 

300 

350 

VMX-SGY-I-430-6-02 

430  132 

250 

250  414  150  150 

150 

350 

450 

110VAC

 

VMX-SGY-I-500-6-02 

500  150 

280 

355  480  150  150 

150 

400 

500 

VMX-SGY-I-430-6-03 

430  132 

250 

250  414  150  150 

150 

350 

450 

230VAC

 

VMX-SGY-I-500-6-03 

500  150 

280 

355  480  150  150 

200 

400 

500 

1)

Rated operational powers in kW as per IEC 60072-1 (primary series) corresponding to IEC current rating.

2)

Rated operational powers in hp corresponding to FLA current rating according to UL508 and Table 430.250 of the
National Electrical Code.

3)

The I

e

 and FLA rating applies for a maximum surrounding air temperature of 50

o

C. Above 50

o

C de-rate linearly by

4% of Ie or FLA per 

o

C to a maximum of 60

o

C.

Содержание VMX-Synergy Plus VMX-SGY-I-100

Страница 1: ......

Страница 2: ...rreur progressif doit tre int gralement v rifi par un agent de maintenance agr Important information Installers should read and understand the instructions in this guide prior to installing operating...

Страница 3: ...ce de protection minimal It is the responsibility of the installer to provide suitable grounding and branch circuit protection in accordance with local electrical safety codes Il appartient l installe...

Страница 4: ...act Com Port Future use USB Port Motor Connections Status LED Modbus RTU Port Expansion Port Supply Connections Control Terminals Under cover Ground Connection Keypad release point Keypad release poin...

Страница 5: ...e 1 VMX SGY I 132 to VMX SGY I 195 Size 2 Dimensions Dimensions VMX SGY I 17 to VMX SGY I 29 Weight 3 9 kg 8 6 lbs VMX SGY I 35 to VMX SGY I 100 Weight 4 2 kg 9 26 lbs VMX SGY I 132 Weight 6 7 kg 14 7...

Страница 6: ...stallation VMX SGY I 242 to VMX SGY I 361 Size 3 VMX SGY I 430 to VMX SGY I 500 Size 3 Dimensions Dimensions VMX SGY I 242 to VMX SGY I 361 Weight 17 0 kg 37 5 lbs VMX SGY I 430 to VMX SGY I 500 Weigh...

Страница 7: ...m2 10AWG 8 71 VMX SGY I 55 to VMX SGY I 80 10mm2 8AWG VMX SGY I 100 16mm2 6AWG M8 stud VMX SGY I 132 to VMX SGY I 160 16mm2 6AWG 12 106 VMX SGY I 195 25mm2 4AWG VMX SGY I 242 35mm2 3AWG VMX SGY I 302...

Страница 8: ...s x number of starts per hour 1200 iERs Disabled Watts VMX Synergy Plus VMX Synergy Plus current rating x 0 6 iERs Enabled The maximum power dissipation occurs when energy saving and the iERS is turne...

Страница 9: ...9 Terminal Designations and Wiring Connection...

Страница 10: ...30Vac or 24Vdc 230Vac factory default 230Vac d faut d usine 4 The system can have either a 110 230Vac mains or 24Vdc input NOT both Le syst me peut avoir soit une alimentation principale de 110 230Vac...

Страница 11: ...re le court circuit dans la section Informations techniques normes du pr sent guide For wire size and torque requirements see Technical Information standards section of this guide Pour les dimensions...

Страница 12: ...utes les configurations de c blage doivent galement tre en conformit avec les codes et les r glements locaux et nationaux en vigueur 2 Power factor correction capacitors must NOT be positioned between...

Страница 13: ...13 Programming OL 0 0A P 0 1a 1b 2 3 4 5 6 7 8 9 Screen 1a on 1st Power On only Subsequent use will show 1b...

Страница 14: ...5 100 VMX SGY I 132 6 01 132 37 75 90 125 40 40 40 100 125 VMX SGY I 160 6 01 160 45 90 110 156 50 50 60 125 150 VMX SGY I 195 6 01 195 55 110 132 192 60 60 75 150 200 VMX SGY I 242 6 01 242 75 132 16...

Страница 15: ...Motor overload cold trip curves 20 C ambient Class10 Class20 Class30 Technical Information Fig 1 Trip curves Note When the overload has tripped there is a forced cooling time to allow the overload to...

Страница 16: ...10VAC or 230VAC 50 60Hz 5Hz Protect with 4A UL 248 Listed fuse Rated control supply voltage Us See Rating Table 2 Amp supply cont Relay specification 11 12 24 and 33 34 44 AC 15 230VAC 1A DC 13 30VDC...

Страница 17: ...40__ Bussmann 170M41__ Bussmann 170M42__ SIBA 20 61___ Fuse rating A 100 100 160 160 200 200 200 315 315 Size 2 and 3 Type designation eg VMX SGY I 132 160 195 242 302 361 430 500 Rated operational cu...

Страница 18: ...0 30 55 55 99 30 30 30 75 100 SGY I 100 SGY I 132 SGY I 160 132 37 75 90 125 40 40 40 100 125 SGY I 132 SGY I 160 SGY I 195 160 45 90 110 156 50 50 60 125 150 SGY I 160 SGY I 195 See Size 3 195 55 110...

Страница 19: ...ize 3 338 90 185 220 312 100 100 125 250 300 SGY I 195 See Size 3 See Size 3 Size 3 Ie 1 kW FLA 1 Hp Trip Class 10 Trip Class 20 Trip Class 30 A 230V 400V 500V A 200V 208V 220 240V 440 480V 550 600V I...

Страница 20: ...ostrokovnjaki in elektrotehni no pou ene osebe Nebezpe enstvo ohrozenia ivota elektrick m pr dom Pr ce ktor s ni ie op san sm vykon vat iba elektroodborn ci a osoby s elektrotechnick m vzdelan m Perig...

Страница 21: ...21 Notes...

Страница 22: ...22 Notes...

Страница 23: ...23 Notes...

Страница 24: ......

Отзывы: