5-19
Application Notes
The average current consumed during each 33.36 ms frame is 79 mA. The illumination
system typically adds 54 mA when enabled. The aiming system typically adds 45 mA when
enabled. Place the SE4400 in standby mode to reduce the current consumption to a steady
current of approximately 230 µA.
Table 5-5. Detailed Breakdown Of Current Profile
Region
Triggering
Event
Start time
w/Respect to
Negative Edge
of VREF (ms)
End time
w/Respect to
Negative Edge
of VREF (ms)
Duration
(ms)
Average
Current
(mA)
Peak
Current
(mA)
Frequency
(Hz)
1
Negative
edge of
VREF
0.000
0.460
0.460
80
145
15.7k
2
0.460
1.777
1.317
36
100
15.7k
3
1.777
1.788
0.011
92
115
374k
4
Negative
edge of
UV6
1.788
1.876
0.088
250
320
374k
5
1.876
2.184
0.308
170
221
374k
6
2.184
2.800
0.616
60
120
15.7k