RFS4011 Series Integrated Services Controller:
Installation Guide
2
1.3 Warnings
•
Read all installation instructions and site survey reports, and verify correct equipment installation before connecting
the system to its power source.
•
Remove jewelry and watches before installing this equipment.
•
Install the equipment in a rack or on a desktop with adequate dimensions and weight allowances.
•
Verify the unit is grounded before connecting it to the power source.
•
Verify any device connected to this unit is properly wired and grounded.
•
Connect all power cords to a properly wired and grounded electrical circuit.
•
Verify the electrical circuits have appropriate overload protection.
•
Motorola strongly recommends the use of an Uninterruptible Power Supply (UPS) that supports the RFS4011 Series
Integrated Services Controller power rating. Not using a UPS can result in data loss or equipment damage due to a
power surge or power failure.
•
Verify that the power connector and socket are accessible at all times during the operation of the equipment.
•
Do not work with power circuits in dimly lit spaces.
•
Do not install this equipment or work with its power circuits during thunderstorms or other weather conditions that
could cause a power surge.
•
Verify there is adequate ventilation around the device, and ambient temperatures meet equipment operation
specifications.
•
This product is designed for in building installation only and is not intended to be connected to exposed (outside
plant) networks.
1.4 Site Preparation
•
Consult your site survey and network analysis reports to determine specific equipment placement, port capacity,
power drops, and so on.
•
Assign installation responsibility to the appropriate personnel.
•
Identify where all installed components are located.
•
Verify appropriate rack mounting requirements, as required.
•
Provide a sufficient number of power drops for your equipment.
•
Ensure adequate, dust-free ventilation to all installed equipment.
•
Identify and prepare Ethernet and console port connections.
•
Verify that cable lengths are within the maximum allowable distances for optimal signal transmission.
•
Verify that the RFS4011 Series Integrated Services Controller is powered through an Uninterruptible Power Supply
(UPS).
CAUTION
Care is required. Disregarding a caution can result in data loss or
equipment malfunction.
WARNING!
Indicates a condition or procedure that could result in personal injury or
equipment damage.
!
RFS4000_Baseline.book Page 2 Tuesday, September 28, 2010 9:55 AM