Бесплатно скачайте Руководство пользователя для Motorola PMP 49400 с нашего веб-сайта. Здесь вы найдете все необходимые инструкции для использования данного устройства. Необходимая информация всегда доступна для скачивания на {веб-сайте}.
PMP 400/430 Series Networks PTP 200/230 Series Bridges
Issue 6
August 2011
Страница 1: ...PMP 400 430 Series Networks PTP 200 230 Series Bridges Issue 6 August 2011 ...
Страница 2: ... and Service Names MOTOROLA SOLUTIONS the stylized M Logo Canopy and all other trademarks indicated as such herein are registered trademarks of Motorola Inc Reg US Pat Tm Office All other product or service names are the property of their respective owners 2011 Motorola Solutions Inc All rights reserved http www motorola com canopy http motorola wirelessbroadbandsupport com ...
Страница 3: ...integrated antenna 27 2 6 3 Specifications for PMP 400 4 9 5 4 GHz AP SM and PTP 200 4 9 5 4 GHz BH radio with integrated antenna 28 2 6 4 Specification for PMP 400 430 AP and PTP 200 BH connectorized radio 29 2 6 5 Specifications for PMP 400 430 kitted connectorized radio antenna included 29 2 7 Performance 31 3 Configuring 41 3 1 Link Operation 1X 2X 3X 41 3 2 Transmitter Output Power and no Jit...
Страница 4: ...Czech Republic Notification 70 5 2 10 Greece Notification 70 5 2 11 Brazil Notification 70 5 2 12 Labeling and Disclosure Table for China 70 5 3 Exposure Separation Distances 71 5 3 1 Details of Exposure Separation Distances Calculations and Power Compliance Margins 71 5 4 Legal Notices 73 5 4 1 Software License Terms and Conditions 73 5 4 2 Hardware Warranty in US 75 5 5 Limit of Liability 75 Lis...
Страница 5: ...PMP 400 CSM 54400 5 4GHz 6 Figure 6 PMP 400 CSM 49400 4 9 GHz 6 Figure 7 PTP 200 Integrated 7 Figure 8 PTP 200 Connectorized 7 Figure 9 PTP 230 Integrated 7 Figure 10 CMM4 56 VDC Power Supply 18 Figure 11 CMMmicro and CMM4 30 VDC Power Supply 18 Figure 12 CMM4 56 VDC and 30 VDC terminal blocks 18 Figure 13 600SS Surge Suppression AP and SM diagram 19 Figure 14 LOS nLOS and NLOS 23 Figure 15 AP Gro...
Страница 6: ...e on SM Configuration General page 51 Figure 29 Active Region Code on SM Home General Status page 51 Figure 30 Ground lug highlighted on AP 61 Figure 31 Dielectric Grease Apply to RJ45 connector 62 Figure 32 Dielectric Grease Insert Ethernet Cable 63 List of Procedures Procedure 1 Assembling a 5 8 or 5 4 GHz AP and attaching to tower 56 Procedure 2 Assembling a 4 9 GHz AP and attaching to tower 58...
Страница 7: ... bridges in 5 8 GHz 5 4 GHz and 4 9 GHz bands Note PMP 400 5 4 GHz Series is replaced with PMP 430 5 4 GHz Series PMP 430 Series 5 4 5 8 GHz Figure 1 PMP 430 CAP 54430 58430 PMP 400 Series 5 4 GHz Figure 2 PMP 400 CAP 54400 5 4 GHz PMP 400 Series 4 9 GHz Figure 3 PMP 400 CAP 49400 4 9 GHz Figure 4 PMP 430 CSM 54430 58430 Figure 5 PMP 400 CSM 54400 5 4GHz Integrated and Connectorized Figure 6 PMP 4...
Страница 8: ...r Guide is available from the User Guides section of the Canopy Document Library http motorola motowi4solutions com support library region 1 cat 8 This guide assumes that the reader has general RF Radio Frequency and Internet Protocol IP knowledge and background This issue Issue 6 is consistent with features provided by Canopy Release 11 0 1 and consistent with features provided by PTP 230 Canopy ...
Страница 9: ... for 1 16 Cyclic Prefix in addition to 1 4 and 1 8 Note PMP 400 Series 5 4 GHz OFDM supports 1 4 Cyclic Prefix o Increased Packets Per Second PPS from 6 800 to 15 000 PPS o 802 1ad Q in Q DVLAN Double VLAN tagging o Dynamic Rate Adapt configurable 1X 2X 3X uplink downlink rate PMP 400 and PTP 200 Series with Release 10 3 o 802 1ad Q in Q DVLAN Double VLAN tagging o Dynamic Rate Adapt configurable ...
Страница 10: ...rature Amplitude Modulation QPSK Quadrature Phase Shift Keying RF Radio Frequency SM VDC VLAN Subscriber Module Volts Direct Current Virtual Local Area Network 1 3 FEEDBACK ON DOCUMENTATION Is this document accurate complete and clear How can it be improved Please send your feedback on Canopy documentation to technical documentation canopywireless com 1 4 TECHNICAL SUPPORT Tip Do not clear the Eve...
Страница 11: ...mark 043682114 France 0157323434 Germany 06950070204 Italy 0291483230 Lithuania 880 030 828 Netherlands 0202061404 Norway 24159815 Portugal 0217616160 Spain 0912754787 Russia 810 800 228 41044 Saudi Arabia 800 844 5345 South Africa 0800981900 United Kingdom 0203 0277499 Asia Pacific Email WiBBsupport apac motorola com 6048503854 9am 5pm Malaysia Time 420 533 336 946 outside hours When you send e m...
Страница 12: ...5 4 and 4 9 GHz BHs as shown in Figure 7 and Figure 8 on page 7 are available with either an integrated antenna or an external N type connector on a short length of coaxial cable for connecting to a connectorized antenna PTP 230 5 4 and 5 8 GHz BHs as shown in Figure 9 on page 7 use the Canopy SM form factor with an integrated antenna PMP 400 430 Series networks are available in multiple bands PMP...
Страница 13: ...0MHz 10 or 20MHz 1 4 1 8 or 1 16 11 0 1 10 7 5 4 GHz PMP 400 Series 54400 PTP 200 Series 54200 10MHz 10MHz 1 4 11 0 1 11 0 1 4 9 GHz PMP 400 Series 49400 PTP 200 Series 49200 10MHz 10MHz 1 4 11 0 1 11 0 1 Table 2 shows the Motorola PMP 430 Series 5 8 GHz OFDM AP and SM models Table 2 5 8GHz OFDM PMP 430 and PTP 230 Series Model Number Descriptions CSM 58430 Model Number 5 8GHz OFDM Subscriber Modu...
Страница 14: ...Requires CMM4 w 56 VDC supply 2 6 5 5780APC 5 8 GHz OFDM Connectorized AP No antenna DES Requires CMM4 w 56 VDC supply 2 6 4 5781APC 5 8 GHz OFDM Connectorized AP No antenna AES Requires CMM4 w 56 VDC supply 2 6 4 PTP 58230 Model Number 5 8GHz OFDM Backhaul BH Description Encryption Picture CMM Type Specs in Section 5780BH10 5 8 GHz OFDM BH 10 Mbps DES Requires CMM4 w 56 VDC supply 2 6 6 5780BH20 ...
Страница 15: ... Mbps DES 2 6 2 5491SM20 5 4 GHz OFDM SM 20 Mbps AES 2 6 2 5490SM40 5 4 GHz OFDM SM Uncapped DES 2 6 2 5491SM40 5 4 GHz OFDM SM Uncapped AES 2 6 2 CAP 54430 Model Number 5 4GHz OFDM Access Point AP Description Encryption Picture CMM Type Specs in Section 5480AP 5 4 GHz OFDM Connectorized AP w antenna DES Requires CMM4 w 56 VDC supply 2 6 5 5480APUS 5 4 GHz OFDM Connectorized AP w antenna US Model ...
Страница 16: ...GHz OFDM Connectorized AP w antenna US Model DES CMMmicro or CMM4 2 6 5 5441AP 5 4 GHz OFDM Connectorized AP w antenna AES CMMmicro or CMM4 2 6 5 5441APUS 5 4 GHz OFDM Connectorized AP w antenna US Model AES CMMmicro or CMM4 2 6 5 5440APC 5 4 GHz OFDM Connectorized AP No Antenna DES CMMmicro or CMM4 2 6 4 5441APC 5 4 GHz OFDM Connectorized AP No Antenna AES CMMmicro or CMM4 2 6 4 PTP 54200 Model N...
Страница 17: ...apped AES Requires 56 VDC supply 2 6 6 Table 5 shows the Motorola PMP 400 and PTP 200 Series 4 9 GHz OFDM AP SM and BH models Table 5 4 9GHz OFDM PMP 400 and PTP 200 Model Number Descriptions CSM 49400 Model Number 4 9 GHz OFDM Subscriber Module SM Description Encryption Picture Power 56 VDC Supply Type Specs in Section 4940SM 4 9 GHz OFDM SM DES Refer to Table 7 for Models 2 6 3 4941SM 4 9 GHz OF...
Страница 18: ... Management Module CMM4 provides GPS synchronization and power to the PMP 400 430 and PTP 200 230 series of products Table 6 details the power requirements of the APs and BHs Table 6 CMM4 56VDC and 30 VDC Operation Frequency PMP Series Access Point AP PTP 230 Series Backhaul BH Canopy Custom Power over Ethernet PoE 5 8 GHz 5 4 GHz PMP 430 Series CAP 58430 54430 PTP 230 Series PTP 58230 54230 56 VD...
Страница 19: ...r details on configuring the CMM4 refer to the CMM4 User Guide which is available from the Motorola support web site http motorola wirelessbroadbandsupport com software Figure 12 CMM4 56 VDC and 30 VDC terminal blocks A Cluster Management Module CMMmicro provides GPS synchronization and 30 VDC power to the 5 4 GHz PMP 400 Series CAP 54400 uses 30 VDC 5 4 GHz PTP 200 Series PTP 54200 uses 30 VDC A ...
Страница 20: ...PMP 400 430 and PTP 200 230 Series Motorola PMP Solutions User Guide Supplement Issue 6 0 May 2011 Page 19 of 77 Figure 13 600SS Surge Suppression AP and SM diagram ...
Страница 21: ...t embedded switch Outdoor enclosure for controller and switch but not power supply 30 VDC power supply included with two models with 10 ft 3m DC cable GPS antenna and mounting bracket 1070CK with N American AC cord for power supply 1070CK 02 no AC cord 1070CK 03 no power supply X X CMMmicro or CMM4 30 VDC power supply w 10 ft 3 m DC cable ACPS112WA with N American AC cord for power supply APCS112W...
Страница 22: ...closure for controller but not power supply GPS antenna and mounting bracket 1091 Power supply is not included Order 56 VDC and or 30 VDC power supply X X X X X 56 VDC power supply for CMM4 Does not include DC cable or AC line cord Procure locally SGPN4076 X X X PMP 400 4 9GHz SM 56 VDC power supply also for standalone use with PMP 430 5 4 and 5 8 GHz AP PMP 400 4 9 GHz AP or PTP 200 5 4 and 4 9 G...
Страница 23: ...nna gain all of which combine to provide longer range within regulatory specified EIRP Equivalent Isotropic Radiated Power Details on performance are listed in Table 8 on page 32 The PMP 400 and PTP 200 Series radios use an OFDM physical layer with 10 MHz channels and 256 sub carriers while the PMP 430 Series radios use an OFDM physical layer with configurable channel bandwidth of 5 10 or 20MHz Th...
Страница 24: ... to help especially when obstacles are near the middle of the link and less so when the obstacles are very near the SM AP or BH However attenuation through walls and trees is substantial for any use of the 5 8 GHz 5 4 GHz or 4 9 GHz frequency bands Even with OFDM these products should not be expected to penetrate walls or extensive trees and foliage 2 2 APPLICATIONS Applications for the PMP 400 PT...
Страница 25: ...ns 5 and 8 and return on pins 4 and 7 PMP 430 Series APs must use a CMM4 with a 56 VDC power supply A CMMmicro will not power these units as it is providing the wrong voltage on the wrong pins PMP 430 Series SMs use a 29 5 VDC wall mount power supply PMP 54400 APs and SMs and PTP 54200 BHs use a nominal 30 VDC power system with power on pins 7 and 8 and return on pins 4 and 5 PMP 54400 APs and PTP...
Страница 26: ... of its U bolts that can be used for terminating ground straps from both the 600SS and the AP Figure 16 600SS pole mount kit 2 5 ADMINISTRATION SYSTEMS Motorola Prizm 3 3 or One Point Wireless Manager v3 0 SP 1 is recommended for managing PMP 400 430 and PTP 200 Series products with Release 11 0 1 and PTP 230 Series products with Release 10 7 Motorola Prizm 3 3 is available for download from the M...
Страница 27: ...5 4 and 5 8 GHz products are sold in the following formats SM Radio with integrated antenna AP Kitted connectorized radio antenna included AP Connectorized radio antenna provided by operator PMP 400 5 4 and 4 9 GHz and PTP 200 5 4 and 4 9 GHz products are sold in the following formats SM BH Radio with integrated antenna AP SM BH Connectorized radio antenna provided by operator AP Kitted connectori...
Страница 28: ...nvironment range of 40 C to 55 C 40 F to 131 F 0 to 95 relative humidity non condensing PMP 400 430 and PTP 200 230 products are available with either DES or AES encryption 2 6 2 Specifications for PMP 430 5 4 5 8 GHz SM and PTP 230 5 4 5 8 GHz BH radio with integrated antenna Radio with an integrated internal vertically polarized antenna 1 lb 11 75 x 3 4 x 3 4 in hwd or 45 kg 29 9 x 8 6 x 8 6 cm ...
Страница 29: ...th integrated antenna Radio with an integrated internal vertically polarized antenna 10MHz channel bandwidth 1 4 Cyclic Prefix 15 5 elevation x 17 5 azimuth 3 dB beam 17 dBi gain for antenna at 5 4 GHz 17 dBi antenna gain plus 10 dBm transmit power gives the regulatory maximum of 27 dBm EIRP 17 dBi gain for antenna at 4 9 GHz 17 dBi antenna gain plus 18 dBm transmit power gives 35 dBm EIRP 2 8 lb ...
Страница 30: ... radio N type connector and connectorized antenna kitted together Antenna optimized for system coverage vs system self interference for 90 sectors 3 dB beam pattern of 60 azimuth by 5 elevation with near in null fill 5 8 GHz 18 dBi gain for antenna 18 dBi antenna gain minus 1 dB cable loss plus 19 dBm tx power gives the U S regulatory max 36 dBm EIRP 5 10 or 20 MHz Channel 13 dBm tx power gives th...
Страница 31: ...es the U S Europe regulatory max 27 dBm EIRP 10MHz Channel 13 dBm tx power gives the U S Europe regulatory max 30 dBm EIRP 20MHz Channel 4 9 GHz 17 dBi gain for antenna 17 dBi antenna gain plus 18 dBm tx power gives 35 dBm EIRP 13 lb 28 x 8 25 x 11 in hwd or 6 kg 71 x 21 x 28 cm hwd Figure 21 CAP 49400 Figure 22 CAP 58430 and 54430 ...
Страница 32: ...230 Series Motorola PMP Solutions User Guide Supplement Issue 6 0 May 2011 Page 31 of 77 2 7 PERFORMANCE Table 8 shows performance details for PMP 400 430 and PTP 200 230 series Round trip latency is 5 7 msec for all platforms ...
Страница 33: ...7 5 Mbps 15 Mbps 22 5 Mbps 20 MHz Channel up down 16 5 Mbps 32 Mbps 45 Mbps 5 4 and 5 8 GHz Nominal Receive Sensitivity including FEC 5MHz Channel 93 dBm 86 dBm 79 dBm 10MHz Channel 90 dBm 83 dBm 76 dBm 20MHz Channel 87 dBm 80 dBm 73 dBm PTP 58230 5 8 GHz OFDM and PTP 54230 5 4 GHz OFDM Modulation QPSK 16 QAM 64 QAM 5 8 GHz Max LOS Range with Integrated BH antenna 6 4 miles 10 24 km 5 miles 8 km 2...
Страница 34: ...nel up down Max Aggregate Throughput with 1 4 cyclic prefix 7 5 Mbps 14 Mbps PMP 20 3 Mbps PTP 21 Mbps Nominal Receive Sensitivity including FEC 89 dBm 78 dBm 70 dBm PMP 49400 PTP 49200 4 9 GHz OFDM Modulation QPSK 16 QAM 64 QAM Maximum LOS Range with integrated SM antenna Note LENS and Reflector cannot be used 10 miles 16 km 4 miles 6 4 km 1 4 miles 2 25 km 10 MHz Channel up down Max Aggregate Th...
Страница 35: ...re use with channels on 10 MHz channel center spacing gives good performance In channel design parlance this can be stated as ABAB channel planning with no guard band needed between A and B A typical arrangement might be to use radios configured for 5480 MHz aimed north and south and radios configured for 5490 MHz aimed east and west Available 5 8 GHz channel center frequencies for each region are...
Страница 36: ...ich are frequencies on which some weather radar operate Table 10 5 4 GHz Channel Center Frequencies by Region Channel Bandwidth Region s Range of Center Frequencies Available MHz Center Channel Spacing of center channels of non overlapping channels 5MHz United States Canada and Australia 5475 5597 5 and 5652 5 5715 2 5MHz 76 38 Europe 5472 5 5597 5 and 5652 5 5717 5 2 5MHz 78 40 Brazil India Russi...
Страница 37: ...regions configured on the Configuration General page of the module it will not allow configuration of the appropriate frequencies as shown in Table 10 Even in regions where use of the spectrum between 5600 and 5650 MHz is allowed the best practice is to not use these channels if there are any other usable channels available Only use the channels in this weather notch after monitoring the spectrum ...
Страница 38: ...spectrum analyzer results for the PTP 100 BHs and PMP 430 5 8 GHz Series Release 10 3 added this enhancement for the PMP 400 430 5 4 GHz PTP 200 BHs and PMP 100 Series The PMP 430 and PTP 230 Series uses average detector rather than peak detector algorithm which results in 10 dBm lower readings than PMP 400 Series and FSK which use peak detectors For example when measuring power from an OFDM AP tr...
Страница 39: ...ween the OFDM and FSK APs may allow collocation with no guard band 15 MHz spacing in some deployments 3 6 2 Frame Calculations and Configuration Settings Interference between collocated Canopy systems can be avoided by following two practices 1 Use a CMM with GPS synchronization This synchronizes frame start so that all collocated APs begin transmitting at the same time each 2 5 millisecond frame ...
Страница 40: ...s 3 7 2 Frame Calculations and Configuration Settings Interference between collocated Canopy systems can be avoided by following two practices 3 Use a CMM with GPS synchronization This synchronizes frame start so that all collocated APs begin transmitting at the same time each 2 5 millisecond frame 4 Use the frame calculators in each module OFDM and FSK the frame calculators are different as frame...
Страница 41: ...rol Slot settings click Calculate and observe the Rec SEQ Start value Iterate usually adjusting the FSK Downlink Data and the OFDM Downlink Data values by a few percent each time until the Rec SEQ Start times of all collocated modules are within 300 bit times of each other Configure the OFDM modules using the resulting OFDM values and the FSK modules using the resulting FSK values The frame calcul...
Страница 42: ... An operator may lock down a link to 1X 2X operation or to only 1X operation using the Dynamic Rate Adapt parameter on the SM s BHS s Configuration General page as shown in Figure 24 This parameter locks down the uplink or downlink operation An operator may lock down an entire sector to 2X and 1X operation or to only 1 X operation using the Dynamic Rate Adapt parameter on the AP s Configuration Ge...
Страница 43: ... India 30 to 19 dBm 19 dBm 17 dBm 36 dBm PMP 430 5 4 GHz OFDM 5 MHz United States Canada Europe India Russia Brazil and Australia 30 to 7 dBm 7 dBm 17 dBm 24 dBm 10 MHz 30 to 10 dBm 10 dBm 17 dBm 27 dBm 20 MHz 30 to 13 dBm 13 dBm 17 dBm 30 dBm PTP 230 5 8 GHz OFDM 10 MHz United States and Canada 30 to 19 dBm 19 dBm 17 dBm 36 dBm Europe and India 30 to 16 dBm 16 dBm 17 dBm 33 dBm 20 MHz United Stat...
Страница 44: ... It may be useful to reduce Transmitter Output Power when Canopy systems are located close together with good coverage given because of their proximity and full power isn t needed or in cases where an operator is trying to reduce interference from the Canopy system to other systems Each SM s Transmitter Output Power is automatically set by the AP The AP monitors the received power from each SM and...
Страница 45: ... bandwidth The default as shown in Figure 26 is 2 miles Set the Range to the distance of the furthest SM from any AP in the area The Range parameter effectively determines frame structure of the Canopy over the air protocol especially turn around guard time Setting Range the same across a geographical area give best overall performance Range does not change transmit power levels Do not set a highe...
Страница 46: ...ers of Control Slots the operator should use the Frame Calculator to find a combination of settings that put Rec SEQ Start times within 300 bit times See section 3 7 2 on page 39 for details Control Slots are reserved for SMs bandwidth requests and never handle data A higher number of control slots gives higher probability that an SM s bandwidth request will be heard when the system is heavily loa...
Страница 47: ...ected on the module s Configuration General page By directing installers and technicians to set the Region Code correctly the operator gains confidence the module is operating according to national or regional regulations without having to deal with the details for each region Available Region Codes include Other United States Canada Europe Brazil India Russia Indonesia and Australia Operators in ...
Страница 48: ...n Code to the region you are in and the equipment will provide DFS consistent with that region s regulations For countries or regions not listed use a Region Code that provides DFS functionality and channels consistent with your country s regulatory requirements 2 In some countries and regions 5600 MHz to 5650 MHz is notched out to meet requirements to not transmit in weather radar frequencies 3 F...
Страница 49: ...t to a different BHM as backhaul links should be configured using color codes and authentication to ensure a BHS only connects with its intended BHM To simplify operation and ensure compliance an SM BHS takes on the DFS type of the AP BHM to which it registers For example when an SM in Europe registers to an AP with the Region Code set to Europe that SM will use ETSI DFS no matter what its Region ...
Страница 50: ...egulatory requirements for DFS must ensure the new Canopy parameter Region Code is set correctly This applies to initial configuration after a module is reset to factory defaults or after a module is upgraded An AP or BHM will not transmit if the Region Code is configured to None IMPORTANT On APs or BHMs received from the factory with Region Code set to None the operator must set the Region Code b...
Страница 51: ...gional Code After an SM BHS registers to an AP BHM it uses the region code of the AP BHM to determine its DFS behavior and displays the AP BHM s region code on its Home General Status page as shown in Figure 30 The two Region Codes on an SM BHS should be the same in normal operation However they will not be the same if for example an SM configured with a Region Code of None has registered to an AP...
Страница 52: ... so does not show a Region Code on its Home General Status page Under normal operations APs and BHMs operating with DFS see Table 14 will experience an additional minute after power up or reboot before they will register any SMs or BHSs SMs and BHSs operating with DFS see Table 14 will experience an additional minute after they reboot before they will register to an AP or BHM It takes two reboots ...
Страница 53: ...smission If radar is detected on the 2nd alternate frequency either during Channel Availability Check or during operation the radio will cease transmission unless or until the primary channel clears its 30 minute lock out The alternate frequencies configured in the AP BHM must be included in the SM BHS s Frequency Scan List or the SMs BHS can t follow their AP BHM if it switches to a new channel A...
Страница 54: ...ctory default of 17 dB If using another antenna set the External Gain to the gain of the antenna minus the loss in coaxial cable and connectors IMPORTANT Ensure the External Gain is set correctly Setting it low or high can lead to either a system overly sensitive to DFS events or a system not transmitting at its full legal power 4 6 NETWORK CONTROL PARAMETERS Parameters for High Priority DiffServ ...
Страница 55: ...on the Configuration Radio page of the BHM The default on a new unit or when the unit is reset to factory defaults is 1 4 Cyclic Prefix In most deployments 1 8 or 1 16 Cyclic Prefix will provide a high quality higher throughput link In cases with severe multi pathing or obstructions 1 4 Cyclic Prefix may give better overall results Procedure for setting the Cyclic Prefix Set the Cyclic Prefix on t...
Страница 56: ...ally applicable to connectorized APs SMs or BHs when the antenna is purchased separately by the operator A short coaxial cable from the radio terminates in a male N connector The antenna has a chassis mounted female N connector The antenna includes tower mount brackets with adjustable down tilt Installing an AP typically consists of four phases 5 Configuring the AP at an operator s facility or at ...
Страница 57: ... diagram that comes with the antenna 3 Connect the radio to the antenna by sliding it into the captive space Secure the radio to the antenna using the two bolts provided 4 Assemble the lower bracket on the antenna assembly Although it may seem intuitive to attach both brackets to the tower or pole and then hang the antenna it usually works better to have the bottom bracket already attached to the ...
Страница 58: ...safety practices for tower climbing Connect the upper bracket to a pole mounting fixture or the tower 7 Hang the antenna assembly on the upper bracket 8 Connect the lower bracket to the pole or tower using the quick connect system provided 9 The quick connect system allows easy attachment detachment and adjustment without any lose parts ...
Страница 59: ...t down tilt per calculations done during Planning Confirm down tilt after the radio is operational using SMs in the field at selected test locations Procedure 3 Assembling a 4 9 GHz AP and attaching to tower 1 Perform a parts check to ensure all parts are present 2 Assemble unit per the instructions that come with the kit ...
Страница 60: ...ge 59 of 77 3 Connect the radio to the antenna by sliding it into the captive space Secure the radio to the antenna using the two bolts provided 4 Connect coax N connector 5 Use standard work and safety practices for tower climbing and connect the upper assembly to a pole mounting fixture or the tower ...
Страница 61: ...orola PMP Solutions User Guide Supplement Issue 6 0 May 2011 Page 60 of 77 6 Adjust down tilt per previous calculations done during Planning Confirm down tilt after the radio is operational using SMs in the field at selected test locations ...
Страница 62: ... over the connector area to provide some resistance to water ingress around the connector 3 Use a 600SS surge suppressor within 3 ft 1 m of the AP and ground it to known good ground Protective Earth PE on the tower or support structure with a 10 AWG ground strap 4 A pole mount kit is available for mounting the 600SS to the tower or mast The mount includes a termination point for the ground strap f...
Страница 63: ...ITH AN INTEGRATED ANTENNA Installing an SM or BH with an integrated antenna is very similar to installing standard Canopy SMs as described in the Motorola PMP Solutions User Guide with the differences outlined below Use an SMMB2 SM mounting bracket for the PMP 54400 and 49400 SM and a SMMB1 mounting bracket for the PMP 58430 54430 SM and PTP 58230 54230 BH The PMP 400 Series SM or the PTP 200 Seri...
Страница 64: ...ns and property in the building PMP 400 430 and PTP 200 230 Series modules do not display a jitter value Use Receive Power Level for aiming and then use Link Tests to confirm alignment The Receive Power Level is a relative not absolute value The Receive Power Level on a module is useful during installation to aid in aiming where relative values over a short period of time are of interest The displ...
Страница 65: ...l device pursuant to Part 15 of the US FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with these instructions may cause harmful interference to radio communications If this equipment does cause harmful inte...
Страница 66: ... on 5730 5845 in 5 MHz increments within the 5725 5850 MHz ISM band 20 MHz channels centered on 5735 5840 in 5 MHz increments within the 5725 5850 MHz ISM band ABZ89FT7635 109W 5790 5 MHz channels centered on 5727 5 5845 in 5 MHz increments within the 5725 5850 MHz ISM band 5790SM 10 dBi 55 x 55 and 3 dB beam width 19 dBm 10 MHz channels centered on 5730 5845 in 5 MHz increments within the 5725 58...
Страница 67: ...ments within the 5470 5725 MHz U NII band with 5600 5650 MHz excluded 5490 SM 5480 BH 5481 BH 10 dBi 55 x 55 3 dB beam width 17 dBm 20 MHz channels centered on 5485 5590 and 5660 5705 MHz in 5 MHz increments within the 5470 5725 MHz U NII band with 5600 5650 MHz excluded 19 dBm 109W 5780 5 MHz channels centered on 5727 5 5845 in 5 MHz increments within the 5725 5850 MHz ISM band 5780APC 17 dBi con...
Страница 68: ...90 MHz public safety licensed band 4940 AP 18 dBi connectorized PCTEL Model AP 85010066001 antenna 60 x 5 3 dB beam width with 1 dB cable loss 18 dBm 4940 SM 4940 BH 17 dBi integrated antenna 15 5 x 17 5 el x az 3 dB beam width 18 dBm Note 1 To ensure regulatory compliance including DFS compliance the professional installer is responsible for setting the Region Code on the Configuration General pa...
Страница 69: ...ms For 4 9 GHz devices The 4 9 GHz band is a licensed band allocated to public safety services State and local government entities that provide public safety services are eligible to apply for 4 9 GHz licenses For additional information refer to Industry Canada regulations 6 2 3 Regulatory Requirements for CEPT Member States www cept org When operated in accordance with the instructions for use Mo...
Страница 70: ...te In some countries or regions collection systems have been set up to handle waste of electrical and electronic equipment In European Union countries please contact your local equipment supplier representative or service center for information about the waste collection system in your country 6 2 6 EU Declaration of Conformity for RoHS Compliance Motorola hereby declares that these Motorola produ...
Страница 71: ...s 6 2 12 Labeling and Disclosure Table for China The People s Republic of China requires that Motorola s products comply with China Management Methods CMM environmental regulations China Management Methods refers to the regulation Management Methods for Controlling Pollution by Electronic Information Products Two items are used to demonstrate compliance the label and the disclosure table The label...
Страница 72: ...paration Distance from Persons PMP 400 430 AP or SM or PTP 200 230 BH At least 20 cm approx 8 in PMP 430 SM or PTP 230 with Reflector Dish At least 1 5 m approx 5 ft PMP 430 SM or PTP 230 with LENS At least 50 cm approx 20 in Canopy Module for comparison At least 20 cm approx 8 in Section 6 3 1 and Table 18 give details and discussion of the associated calculations 6 3 1 Details of Exposure Separa...
Страница 73: ...e S power density in W m 2 P RMS transmit power capability of the radio in W G total Tx gain as a factor converted from dB d distance from point source in m Rearranging terms to solve for distance yields d P G 4 S Table 18 shows calculated minimum separation distances d recommended distances and resulting power compliance margins for each frequency band and antenna combination Table 18 Calculated ...
Страница 74: ...able consideration the receipt and sufficiency of which are hereby mutually acknowledged you and Motorola agree as follows Grant of License Subject to the following terms and conditions Motorola Inc grants to you a personal revocable non assignable non transferable non exclusive and limited license to use on a single piece of equipment only one copy of the software contained on this disk which may...
Страница 75: ... EVENT SHALL MOTOROLA OR ANY OF THE LICENSORS DIRECTORS OFFICERS EMPLOYEES OR AFFILIATES OF THE FOREGOING BE LIABLE TO YOU FOR ANY CONSEQUENTIAL INCIDENTAL INDIRECT SPECIAL OR SIMILAR DAMAGES WHATSOEVER including without limitation damages for loss of business profits business interruption loss of business information and the like whether foreseeable or unforeseeable arising out of the use or inab...
Страница 76: ...shared equally Nothing in this Section will prevent either party from resorting to judicial proceedings if i good faith efforts to resolve the dispute under these procedures have been unsuccessful ii the dispute claim or controversy involves intellectual property or iii interim relief from a court is necessary to prevent serious and irreparable injury to that party or to others General Illinois la...
Страница 77: ...s User Guide Supplement Issue 6 0 May 2011 Page 76 of 77 exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you IN NO CASE SHALL MOTOROLA S LIABILITY EXCEED THE AMOUNT YOU PAID FOR THE PRODUCT ...