5-2
RADIO TUNING AND PROGRAMMING
2.1
Initial Test Equipment Setup
The supply voltage is connected to the radio using a Motorola battery eliminator, P/N 0180305H20.
The initial test equipment (Figure 5-1) control settings are listed in Table 5-2.
3.0
CPS Programming Setup
The CPS programming setup, shown in Figure 5-2, is used to program the radio codeplug.
Figure 5-2
CPS Programming Setup
NOTE
Refer to appropriate program on-line help Þles for the tuning procedures.
Table 5-2
Initial Equipment Control Settings
Service Monitor
Test Set
Power Supply
Monitor Mode: Power Monitor
Speaker set: A
Voltage: 7.5Vdc
RF Attenuation: -70
Speaker/load:
Speaker
DC on/standby:
Standby
AM, CW, FM: FM
PTT: OFF
Volt Range: 10V
Oscilloscope Source: Mod
Oscilloscope Horizontal: 10mSec/Div
Oscilloscope Vertical: 2.5kHz/Div
Oscilloscope Trigger: Auto
Monitor Image: Hi
Monitor BW: Nar
Monitor Squelch: mid CW
Monitor Volume: 1/4 CW
Current: 2.5A
NOTE
Refer to appropriate program on-line help Þles for the codeplug programming procedures.
RIB
RLN4008
RIB Power Supply
RLN4460
Test Box
Rx
Gnd
Data
Tx Data
Radio
Battery
Computer Interface
Cable
Program/
PMKN4004
Test Cable
3080369B72
DB15
DB9
120/230 Vac
Power
Supply
RLN4510
+12VDC
Battery
Eliminator
7.5V Reg.
Block
0180305H20
Содержание P Series
Страница 1: ...Professional Radio P Series Basic Service Manual 68P64115B49 Issue September 1999 ...
Страница 11: ...1 4 INTRODUCTION ...
Страница 15: ...2 4 INTRINSICALLY SAFE RADIO INFORMATION ...
Страница 37: ...3 22 MAINTENANCE ...
Страница 43: ...4 6 PERFORMANCE TESTING ...
Страница 47: ...6 2 POWER UP SELF TEST ...