![Motorola MPMC101 Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/motorola/mpmc101/mpmc101_user-manual_241186033.webp)
Connecting to the SCSI Bus
2-13
2
Connecting to the SCSI Bus
You are now ready to connect the adapter to the SCSI bus.
!
Caution
Single-ended and differential SCSI devices are
electronically incompatible and cannot be mixed on the
same physical bus. Mixing single-ended and differential
SCSI devices on the same bus can cause permanent
damage to both the peripherals and the PCI adapter.
!
Caution
Cables of different impedance should not be mixed on
the same physical bus.
Table 2-3. Connector and Cable Requirements
Connectors
68-pin Euro style SCSI:
Shielded
- external or internal cabinet
applications
Non-shielded
- internal cabinet
applications only
Bus Cable
68-conductor, flat ribbon or discrete:
Single-ended
:
Type - Twisted pair only
Shielding - match with connector
Max bus length - 6 meters
Differential:
Type - twisted pair only
Shielding - match with connector
Max bus length - 25 meters
Содержание MPMC101
Страница 1: ...MPMC101 PMC SCSI 2 Adapter User s Manual PMC101A UM1 ...
Страница 12: ...xii ...
Страница 30: ...2 10 Hardware Installation 2 Figure 2 9 Installing the PMC Adapter P1 P2 ...
Страница 44: ...4 4 Troubleshooting 4 User Notes ...