Chapter 2: Infrastructure Device Installation
July 2007
2-8
•
The antenna must have a separation distance of at least 2 meters from the body of all
persons and must not be co-located or operating in conjunction with any other antenna
or transmitter.
•
Users and installers must be provided with antenna installation and transmitter operating
conditions to satisfy RF exposure compliance.
•
When deploying the MOTOMESH Duo 4300 device, the antenna(s) should be a
minimum of 30 inches from any nearby metal poles to avoid distortion of the RF pattern.
•
The installation location must provide power to the MOTOMESH DUO 4300 Device.
•
It is the responsibility of the Network Operator to ensure that the installation complies
with any local building codes and permits.
Grounding Considerations
In order for a grounding system to be effective, a low impedance path to earth ground must be present.
The grounding system must have conductors of sufficient size to withstand the high fault currents that
must be shunted along this path. The lower the impedance the grounding system displays, the better its
capability to perform its task. The impedance requirement for a communications site is determined by
the classification of the site. Sites are broken down into 2 categories: Type A-Light Duty and Type B-
Light Industrial/Commercial. Type A-Light Duty sites have impedance requirements of 25 ohms or
less to ground whereas Type B- Light Industrial/Commercial sites have impedance requirements of
less than 5 ohms to ground. MOTOMESH networks fall into the Type B-Light Industrial/Commercial
category, and therefore must be treated with greater considerations as far as grounding requirements
are concerned.
Since Type B grounding requirements stipulate 5 ohms or less impedance to earth ground, things such
as soil pH, type of grounding rods, size of conductors, and ground enhancing materials must be taken
into account to achieve this goal. To verify the impedance requirements are met, a special
Earth/Ground Resistance Tester (megohmmeter) may be necessary.
•
If the MOTOMESH product is attached to a light arm and the attachment point meets
the Type B grounding requirements, then the grounding stud attachment point is not
required to be used.
To avoid damage to the equipment, adequate grounding for all MOTOMESH
devices is mandatory.
Assembling an AC Power MOTOMESH Duo Device
Use the following procedure to assemble a MOTOMESH Duo Device with AC power.
Procedure 2-1 Assembling an AC Power MOTOMESH Duo Device
1
Place the brackets at the desired position on the pole.
Содержание MOTOMESH DUO 2.0 4300
Страница 1: ...MOTOROLA MOTOMESH DUO 2 0 4300 Users Guide July 2007 ...
Страница 2: ...MOTOMESH DUO 2 0 4300 Users Guide July 2007 ii This page intentionally left blank ...
Страница 4: ...MOTOMESH DUO 2 0 4300 Users Guide July 2007 iv This page intentionally left blank ...
Страница 8: ...List of Figures July 2007 viii This page intentionally left blank ...
Страница 10: ...List of Tables July 2007 x This page intentionally left blank ...
Страница 12: ...List of Procedures July 2007 xii This page intentionally left blank ...
Страница 30: ...Chapter 2 Infrastructure Device Installation July 2007 2 10 This page intentionally left blank ...
Страница 58: ...Chapter 5 Customer Service July 2007 5 4 This page intentionally left blank ...
Страница 70: ...Chapter 6 Certification and Safety Information July 2007 6 12 This page intentionally left blank ...
Страница 74: ...Glossary July 2007 Glossary 2 This page intentionally left blank ...