MC145220EVK
MOTOROLA
36
[Z] Change default high frequency
To access this command in the program, select a board in the “Define boards to program” screen and
then press [Q]! . This will place you in the “Select from the available options” screen. The command [Z] is
on this screen.
See page 21 of this document for a sample screen shot of this command.
This command prompts the user to input a decimal value in MHz for the default high frequency. The pro-
gram default high value is displayed along with the current value. The user may leave the high frequency
value as is by entering return without a value. The program high default value is dependent on the tar-
geted board type. (See Table 6.)
This value is not sent to the board immediately. It is the value that is sent to the board when the [L] com-
mand is executed.
Table 6.
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Board Type
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Program Default High Frequency
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MC145190
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
751 MHz
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MC145191
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
743 MHz
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MC145192
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
743 MHz
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MC145200
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
1502 MHz
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MC145201
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
1486 MHz
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Á
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Á
MC145202
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Á
1486 MHz
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Á
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Á
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
MC145220 in Single Loop Mode
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Á
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
743 MHz (PLL)
820 MHz (PLL
′
)
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Á
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Á
MC145220 in Dual Loop Mode
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Á
80 MHz
[U]! Step frequency up by step size
To access this command in the program, select a board in the “Define boards to program” screen and
then press [Q]! . This will place you in the “Select from the available options” screen. The command [U]!
is on this screen.
See page 21 of this document for a sample screen shot of this command.
This command increments the NCOUNTER and ACOUNTER fields of the A register for the currently
targeted board. This steps up the PLL’s frequency by the current step size for the board.
If the currently selected board is an MC145220 in DUAL mode, then the currently targeted PLL on the
board is “stepped”. If the MC145220 is in SINGLE mode, then both PLLs on the board are “stepped”.
[D]! Step frequency down by step size
To access this command in the program, select a board in the “Define boards to program” screen and
then press [Q]! . This will place you in the “Select from the available options” screen. The command [D]!
is on this screen.
See page 21 of this document for a sample screen shot of this command.
This command decrements the NCOUNTER and ACOUNTER fields of the A register for the currently
targeted board. This is the effect of stepping down the PLL’s frequency by the current step size for the
board.
If the currently selected board is an MC145220 in DUAL mode, then the currently targeted PLL on the
board is “stepped”. If the MC145220 is in SINGLE mode, then both PLLs on the board are “stepped”.