NOTE: MC145220 selections are not implemented in rev. 2.5.
[A]! Set board A as target
This command sets the target board to the board shown as A. This means that the commands that follow
will affect board A only. The user is informed of, and may modify, the target board in any screen of the
program except the help screen.
This is strictly an internal program command and has no effect on the MC145xxx EVKs connected to the
computer.
[B]! Set board B as target
This command sets the target board to the board shown as B. This means that the commands that follow
will affect board B only. The user is informed of, and may modify, the target board in any screen of the
program except the help screen.
This is strictly an internal program command and has no effect on the MC145xxx EVKs connected to the
computer.
[C]! Set board C as target
This command sets the target board to the board shown as C. This means that the commands that follow
will affect board C only. The user is informed of, and may modify, the target board in any screen of the
program except the help screen.
This is strictly an internal program command and has no effect on the MC145xxx EVKs connected to the
computer.
[L]! Set to low freq.
This command is used to set the frequency of the currently selected board to the currently defined low
value. This value can be changed via the [W] command.
This is accomplished by correctly adjusting the A register for the targeted board.
If the current EVK is the MC145220 and the board is in DUAL mode, then the currently targeted PLL on
the board is set to the specified low frequency. Otherwise, if the board is in SINGLE mode, both on–
board PLLs are set to the new frequency.
[M]! Set to medium freq.
This command is used just as the [L]! command except that the defined medium frequency value is used.
This default value can be changed by selecting command [N]. Reference [L]! command for further de-
tails.
[H]! Set to high freq.
This command is used just like the [L]! command except that the defined high frequency value is used.
This default value can be changed by selecting command [W]. Reference [L]! command for further de-
tails.