MOTOROLA
ELECTRICAL CHARACTERISTICS
MMC2001
A-6
REFERENCE MANUAL
PRELIMINARY
A.4.4 ISPI Timing Specifications
Table A-7 ISPI Timing Specifications
Num
Characteristic
Symbol
Min
Max
Unit
Operating Frequency (SCLK)
f
op(s)
DC
1/8
CLK
51
Cycle Time
t
cyc
8
1024
CLK
52
Enable Lead Time
PHA=0
PHA=1
t
lead
1
1
—
—
SCLK
53
Enable Lag Time
PHA=0
PHA=1
t
lag
1
1
1
1
SCLK
54
Clock (SCLK) High Time
t
w(SCKH)
4
512
CLK
55
Clock (SCLK) Low Time
t
w(SCKL)
4
512
CLK
56
Data Setup Time (Inputs)
t
su
8
—
ns
57
Data Hold Time (Inputs)
t
h
8
—
ns
58
Access Time Slave
t
a
1
—
SCLK
59
Disable Time (Hold Time)
t
dis
—
1
SCLK
60
Data Valid (After Enable Edge)
t
v(s)
—
5
ns
61
Data Hold Time (Output) (After Enable Edge)
t
ho
0
—
ns
62
Rise Time (20% V
DD
to 70% V
DD
, C
L
= 20pF)
Manual/Interval Mode
Slave Mode
t
rs
—
—
10
10
ns
63
Fall Time (20% V
DD
to 70% V
DD
, C
L
= 20pF)
Manual/Interval Mode
Slave Mode
t
fs
0
0
10
10
ns
64
Sequential Transfer Delay
1
NOTES:
1. Signal depends on software in interval mode.
t
bt
1
—
SCLK
Freescale Semiconductor,
I
Freescale Semiconductor, Inc.
For More Information On This Product,
Go to: www.freescale.com
nc.
..