Document No.: 540038-001

DSR-4550 Commercial

Integrated Receiver/

Decoder Operator Guide

Содержание DSR-4550

Страница 1: ...Document No 540038 001 DSR 4550 Commercial Integrated Receiver Decoder Operator Guide ...

Страница 2: ...arty modifying the decoder to fines imprisonment and civil damages NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate ra...

Страница 3: ...ies specified by the manufacturer Unplug this apparatus during lightning storms or when unused for long periods of time This apparatus shall not be exposed to dripping or splashing No objects filled with liquids such as vases shall be placed on the apparatus Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as when the powe...

Страница 4: ... y al vendedor y a la parte que modifica el decodificador a multas prisión y daños civiles NOTA Este equipo se ha probado y se ha demostrado que cumple con los límites para un dispositivo digital clase A según la parte 15 de las normas de la FCC Estos límites están diseñados para ofrecer protección adecuada contra interferencia dañina cuando el equipo se utiliza en un entorno comercial Este equipo...

Страница 5: ...plo cuando el cable de alimentación o enchufe está dañado se ha derramado líquido o el aparato ha sido golpeado por otros objetos cuando se ha expuesto a lluvia o humedad no funciona normalmente o se ha caído Proteja el cable de alimentación para evitar pisarlo o que quede apretado especialmente en los enchufes y tomas de corriente y revise el punto de salida del aparato Use exclusivamente los acc...

Страница 6: ......

Страница 7: ...ering On the DSR 4550 9 Chapter 3 Operating the DSR 4550 11 Using the Front Panel 12 Navigating the Menus 13 How to Use the Menus 14 About Menu 14 Main Menu 14 Overview of the LCD Panel Menu Tree 15 Installation Menus 18 Manual Tune Menu 18 Modulation Menu 21 Port Menu 22 Port Config Menu 24 Port Test Field 24 Audio1 and Audio2 Menus 24 Audio1 Gain and Audio2 Gain Menus 26 Subcarrier Menu 27 Alarm...

Страница 8: ...ct Menu 40 Program Menu 40 Aud1Lang Aud2Lang Menus 41 InputMode Field 43 Text Lang Menu 43 EMM ID Menu 44 Checking Status of Channel 44 IP Menus 45 MAC Address Menu 45 IP Address Menu 45 Subnet Mask Menu 46 IP Gateway Menu 46 GigE Menus 47 GigE MAC Address Menu 47 GigE IP Address Field 47 GigE Subnet Mask Menu 48 GigE Default Gateway Menu 48 GigE MPTS Address Menu 49 MPTS Address Field 49 Port Fie...

Страница 9: ...nu 56 TVPass Card Menu 56 Audio Test Signal Menu 57 Video Test Signal Menu 58 VITS Menu 59 Ad Insertion Test Menu 61 Chapter 4 Troubleshooting 63 Chapter 5 Downlink L band Frequency Conversion Tables 65 Chapter 6 Product Support 67 If You Need Help 67 Calling for Repairs 68 Chapter 7 Language Abbreviations 69 Chapter 8 Diagnostics 71 Introduction 71 Viewing the Fast Fact Diagnostic Screens 72 Fast...

Страница 10: ......

Страница 11: ...ts compliant with MPEG 2 standard 8PSK Phase Shift Keying modulation with turbocodes for matched transponders Operational modes include DCII MAN DVB MAN and 8PSK SDI Output with two channels of embedded audio Two AES EBU digital audio outputs The user is able to select an input L band frequency of 950 to 2150 MHz The user can select any of the following code rates 5 11 1 2 3 5 2 3 3 4 4 5 5 6 and ...

Страница 12: ...pport for GigE Digital Storage Medium Command and Control DSMCC ASI input that decrypts and decodes the selected service Ethernet Port for SNMP control and or IP data pass through DTMF output and relay control of tape machines and other ad insertion equipment Four Form C relays used for fault alarm indication or uplink control Memory to recall the operating configuration when power sags or is remo...

Страница 13: ... seconds Note Transponder search entry delay time is set up by the uplink equipment Automatically terminates disaster recovery when the lost signal is acquired Acronyms The following acronyms are used within this manual AES EBU Audio Engineering Society European Broadcasting Union ASI Asynchronous Serial Interface APL Applied Physics Laboratory BNC Bayonet Navy Connector CATV Cable Television CND ...

Страница 14: ...rt Stream Msps Mega symbols Per Second NEC National Electric Code NTSC National Television System Committee OSD On Screen Display PAL Phase Alternation by Line PID Packet ID PMT Program Map Table RF Radio Frequency RSA Return Service Authorization RU Rack Unit SDI Serial Digital Interface SID AMOL Source Identification Automatic Measurement of Lineups TSID Transport Stream Identification VITS Vert...

Страница 15: ...GE 10 100 RF IN ASI IN ASI OUT SDI OUT AUX VIDEO IN VIDEO OUT VIDEO OUT OSD 8 Digital Audio Out 1 2 AUX AUDIO IN PRIMARY AUDIO RELAY1 ASYNC GNDL L GND R R L L GND R R NO COMNC GNCNO COMNC ALARM RELAY2 RELAY3 SECONDARY AYDIO C C GND Q Q D D TVPass Card RF Input Ports 1 8 ASI In OSD Video Out Video Out AUX Video In Auxiliary Audio In Primary Audio Out Power Connector Cue Tone Relay Alarm SDI Out Dig...

Страница 16: ...through Phoenix Contact part numbers 1840447 1840528 Note D D C and C are ISOC signals D is Data C is Clock and Q and Q are cue tone signals Note GigE and 10 100 ports are standard RJ 45 Ethernet AC 100 240V 50 60 Hz 60 W 1 2 3 4 5 6 7 TVPass Card ETHERNET GIGE 10 100 RF IN ASI IN ASI OUT SDI OUT AUX VIDEO IN VIDEO OUT VIDEO OUT OSD 8 Digital Audio Out 1 2 AUX AUDIO IN PRIMARY AUDIO RELAY1 ASYNC G...

Страница 17: ...550 s warm air output from within the mounting rack Motorola Mobility recommends the use of a fan on top of the rack Circuit Overloading If the DSR 4550 is connected to a power strip rather than a branch circuit s direct connection use special care to ensure that the unit is properly connected Always consider the affect that overloading circuits might have on over current protection and supply wir...

Страница 18: ...odulator Refer to Viewing the Fast Fact Diagnostic Screens on page 72 4 To listen to audio during installation connect the audio outputs to a local amplifier and speaker A standard stereo system will suffice but the lack of differential audio inputs may make the audio seem degraded After the DSR 4550 is authorized and providing the desired service reconnect these outputs to the channel modulator S...

Страница 19: ...outputs the specified service Powering On the DSR 4550 To apply power to the DSR 4550 perform the following steps 1 Plug the DSR 4550 into a power source and all LEDs on the front panel are illuminated while the front panel LCD screen is blank After approximately 60 seconds the LEDs go out and the LCD screen displays a screen similar to the following This screen is displayed for only 30 seconds th...

Страница 20: ......

Страница 21: ... described in this chapter require use of the DSR 4550 front panel as shown in Figure 3 1 Figure 3 1 DSR 4550 Front Panel Relay 1 Relay 2 Relay 3 Alarm LCD Screen Authorized Signal Bypass Download Arrow Buttons ENTER Button RELAY 1 RELAY 2 RELAY 3 ALARM ...

Страница 22: ...ave an arrow indicator just to the left of the field label During left right navigation the cursor skips over the labels that cannot be changed The LCD is momentarily backlit with circuitry that turns off the backlighting approximately four minutes after the last button press or warning screen To view the screen after backlighting has turned off press any button once to turn on the backlighting In...

Страница 23: ...a field label top row pressing the ENTER button causes the cursor to move below the label and enter into the field so the setting can be changed When the cursor is below the label the displayed directional controls in the left corner show what buttons can be pressed to change the setting in that field Usually the buttons are used to display the various options associated with a particular field In...

Страница 24: ...d from any other menu by pressing the ENTER button while the cursor is blinking next to the menu name on the far left of the menu screen The Main menu shown below allows the user to select any one of the five main menu groups Installation menus see page 18 Channel menus see page 37 IP menus and GigE menus see page 45 and page 47 Status menus see page 50 Diagnostics menus see page 55 The DSR 4550 a...

Страница 25: ...R button when the cursor is on a menu name causes the cursor to return to the main top level menu The charts on the following pages show the menus organized into five main groups Installation menus Channel selection menus IP menus including the GigE menus Status menus and Diagnostics menus ...

Страница 26: ...us E 00000 MPEG SELECT Program E 00000 0000 Not in map CHANNEL VCT Chnl Xpndr AUD2LANG Dspl Left Right InputMode E All def def E All def def AUD1LANG Dspl Left Right InputMode E All TEXT LANG Display E 0000 EMM ID ID Number Hex ...

Страница 27: ... L1 R1 L2 R2 E Off VIDEO TEST SIGNAL Pattern E Off Off AD INSERTION TEST Cue Tone Relay Status Menus E STATUS3 Signal_Quality E STATUS4 Sat Freq Symb Code Format E Tuning 2 0 STATUS5 Sync Eb No Authorize State E STATUS2 Source Channel Quality E Local Control L Band STATUS1 FrontPanel Input Type E Undefined Undefined Undefined STATUS7 IP Data Isoc Data Async Data E 42 9MB 47 8MB STATUS6 Memory Flas...

Страница 28: ...ting a transponder frequency for each of the eight L Band inputs which are labeled Port 1 through Port 8 In addition this menu allows a user to select ASI In as the desired signal input to the DSR 4550 When an L band port is selected the user must additionally specify an L band frequency and modulation format For more details see Modulation Menu on page 21 Because the North American C band frequen...

Страница 29: ...lable when the ASI In option in the Input field is selected The Mode field allows selection of the frequency plan type for the satellite to which the DSR 4550 is tuned Note If the application is a North American C band satellite select the transponder number in the Xpnr field Otherwise use the LFreq option and the LFreq field The LFreq option can be used for all satellites including current C band...

Страница 30: ... The LFreq field cannot be edited if Xpndr in the Mode field is chosen Contact the programmer or network operator for details about the satellite transponder and frequencies being used during installation The LFreq field defines the L band frequency to which the unit tunes during installation If the LFreq option in the Mode field is selected use this field to directly tune the IRD to the required ...

Страница 31: ...ress the ENTER button to move into the field Press the buttons to display the options DCII AUTO DCII MAN 8PSK Phase Shift Keying Modulation with turbocodes or DVB MAN Select a mode and press ENTER to exit the field Note In any of the non auto modes i e DCII MAN DVB MAN both manual modes or 8PSK Phase Shift Keying Modulation with turbocodes the DSR 4550 only searches for a signal that matches what ...

Страница 32: ...he required combination by pressing the ENTER button to return to top menu Port Menu Note This menu is not available when the ASI In option is selected That option is described in Manual Tune Menu on page 18 The Port menu is available when the Manual Tune input setting is one of the L band ports as described in the Manual Tune Menu on page 18 In order to use virtual channels one or more ports must...

Страница 33: ...eviated name two or three alphanumeric characters for the satellite to which the selected port is associated when the Manual mode is selected The Satellite field is a user configurable parameter which the unit may overwrite depending on information received in download tables Press the 4 button until the cursor is at the Satellite label Press the ENTER button to enter this field use the 4 buttons ...

Страница 34: ...allow the user to customize the audio output based on options provided by the digital audio compression Press the buttons until the Audio1 or Audio2 menu appears shown below DialNorm Field Default On The DialNorm field allows the user to normalize speech levels to a constant level over all channels raising or lowering the volume of the dialogue to a level that is appropriate for the background sou...

Страница 35: ...anguage previously selected for Mono or Stereo for both left and right The DSR 4550 now requires e a language defined for both left and right dual mono outputs Conversely if the user had previously selected Dual Mono output in two languages but later changed to Stereo or Mono output in this menu the output reverts to the Dual Mono language that is defined for the left channel Compress Field Defaul...

Страница 36: ...iew the two options Independent Each channel is set up and controlled independently Joint Both channels are configured jointly using the Left field settings as the control for both audio channels Press the ENTER button to select the option shown and exit the field Left and Right Fields Default 0 Note The Right field is not editable when the Joint option is set for the Mode field The Left and Right...

Страница 37: ...pressed in dB range is 15db to 00dB Press the 4 button until the cursor is at the Gain label and press the ENTER button to move into the field Press the buttons to set the standard audio gain for a manually tuned analog signal Then press the ENTER button to confirm the selection L Freq and R Freq Fields Default Left 6 20 MHz Right 6 80 MHz The L Freq and R Freq fields defines the subcarrier freque...

Страница 38: ...iggered when the IRD is not authorized to access a selected service Press the ENTER button to select the option shown and exit the field Bypass Field Default Alarm Press the 4 button until the cursor is at the Bypass label and press the ENTER button to move into the field Press the buttons to display the options If Bypass is selected the Bypass mode is activated and the DSR 4550 loops through the ...

Страница 39: ... Byte options specify the transport stream packet structure When the ASI Output is enabled the DSR 4550 outputs MPEG 2 transport stream packets either as a burst of contiguous bytes Packet option or as individual bytes Byte option Press the 4 button until the cursor is at the Format label and press the ENTER button to move into the field Press the buttons to display the options Packet or Byte Pres...

Страница 40: ...t the system to the programming values originally set by the factory firmware When the option is shown press the ENTER button and a caution message is displayed Press any arrow button 4 to back out of the field and leave it unchanged Otherwise press the ENTER button to proceed During factory reset the following message is displayed Power Cycle Option The Power Cycle option reboots the DSR 4550 wit...

Страница 41: ... at the Contrast label and press the ENTER button to move into the field Use the arrow buttons 4 to select a value between 1 and 30 with 1 representing the least contrast and 30 the most Adjust the contrast so that the LCD panel can be read clearly Press the ENTER button to confirm the selection TSID Field Default 0000 Note The Transport Stream ID TSID field is not supported at this time The TSID ...

Страница 42: ...r is a 625 line the field selects the type of PAL the receiver outputs and the NTSC or PAL M selection has no impact 525 Lines Field Default NTSC Press the 4 button until the cursor is at the 525 Lines label and press the ENTER button to move into the field Press the buttons to display the desired options of NTSC or PAL M and press the ENTER button to confirm the selection and exit the field 625 L...

Страница 43: ...onverts 16x9 source video to a 4x3 aspect ratio in the zoom pan scan or letterbox format based on what is selected for the Output field Press the 4 button until the cursor is at the Output label Press the ENTER button to enter the field Press the buttons to display the desired options of 16x9 4x3 ZOOM 4x3 PAN information in the video material directs which portion of the 16x9 image to output and 4...

Страница 44: ...ar of the DSR 4550 Press the buttons to enable or disable AES and press the ENTER button to confirm the selection AC 3 Compression Menu The AC 3 Compression Menu displays the current AC 3 compression selections either internal or external for audio 1 and audio 2 channels Press the buttons until the AC 3 Compression menu appears shown below Audio 1 and Audio 2 Field Default Internal The Audio 1 or ...

Страница 45: ...table Upgrade Field The Upgrade field displays the version of the upgrade code that is available This field displays 000000 when no upgrade code is available Available upgrades are installed the next time the DSR 4550 is powered on This field is non editable Download Menu The Download menu allows the user to monitor the status of the current code download This menu is used most commonly in trouble...

Страница 46: ...ndicates the ID for the current segment received by the DSR 4550 during the download of the file This field is non editable Rcvd Field The Rcvd field indicates ID for the last segment of the file selected in the File field This field is non editable Total Field The Total field indicates the number of segments that the DSR 4550 has received for the file selected in the File field This field is non ...

Страница 47: ...is field allows selection of a Virtual Channel Table VCT number Press the 4 button until the cursor is at the VCT label and press the ENTER button to move into the field While ensuring that the cursor remains on the up down symbol press the buttons to scroll throughout the available VCTs Note If the network has four VCTs then only four VCTs appear in this field Press the ENTER button to confirm th...

Страница 48: ...rsor is on that digit press the buttons to select the desired value Repeat this process for each applicable digit to be changed Press the ENTER button to confirm the selection and exit the field CAUTION MESSAGES When selecting changing the Chnl field the DSR 4550 displays caution messages under the following three conditions A warning message is displayed when the user changes from a virtual chann...

Страница 49: ...el that does not match the satellite and polarity attributes of either port then the DSR 4550 is unable to determine which port to use and the following caution message is displayed Press any arrow button 4 to back out of the field and leave it unchanged Note The DSR 4550 cannot decode the chosen virtual channel until a port is set up with the applicable satellite and polarity information Xpndr Fi...

Страница 50: ... field There is also a second method for entering the MPEG program number Use the 4 buttons to select the digit to change and then while the cursor is on that digit press the buttons to select the desired value Repeat this process for each applicable digit to be changed CAUTION MESSAGES When selecting changing the MPEG program numbers the DSR 4550 displays warning messages for the following two co...

Страница 51: ...ight fields You may wish to select languages that are not functional at this time but will be functional in the future when they are present on the channel Press the ENTER button to confirm the selection The Avail Available option allows the user to scroll through the languages supported by the system while the cursor is in the Left and Right fields Furthermore selection of this option allows the ...

Страница 52: ...lds indicate the occurrence of the specified language The range is between 00 and 99 For example use eng13 for the 13th version of the English This feature is used when there are multiple dialects within a language Use the 4 buttons to select the alphanumeric character to change and then while the cursor is on that alphanumeric character press the buttons to select the desired alphanumeric charact...

Страница 53: ...reen displays After changing the AudioMix menu to Dual Mono reselect the languages desired here in this menu If the user previously selected Dual Mono in the AudioMix field with two different languages as audio outputs in the Language menu but later selects Stereo Stereo Surround or Mono in the AudioMix field the output in this Language menu automatically is set to the first occurrence of a specif...

Страница 54: ... move into the field Use the 4 buttons to select the digit to change and then while the cursor is on that digit press the buttons to display the desired value Repeat this process for each applicable digit Press the ENTER button to confirm the selection Checking Status of Channel Once a channel is set up the user can verify the status of the channel To do this access the Status Display menus by pre...

Страница 55: ...t on the back panel of the DSR 4550 The address is represented in the common dotted decimal format Contact the network administrator for details about configuring the Ethernet port for operation on your local network Press the buttons until the IP Address menu appears shown below Important Do not configure the IP Address of the 10 100 and GigE to be on the same subnet To change the IP address pres...

Страница 56: ... button to confirm the selection and exit the field IP Gateway Menu Use the following procedure to set and view the IP Gateway address range 000 000 000 000 to 255 255 255 255 for the lower Ethernet port on the back panel of the DSR 4550 The IP Gateway is an address that is represented in the common dotted decimal format Contact the network administrator for details about configuring the Ethernet ...

Страница 57: ...iew the GigE IP address range 000 000 000 000 to 255 255 255 255 for the upper Ethernet port on the back panel of the DSR 4550 The address is represented in the common dotted decimal format Contact the network administrator for details about configuring the GigE port for operation on your local network Press the buttons until the GigE IP Address menu appears shown below Press the 4 button until th...

Страница 58: ...m the selection and exit the field GigE Default Gateway Menu Use the following procedure to set and view the GigE Default Gateway address range 000 000 000 000 to 255 255 255 255 for the upper Ethernet port on the back panel of the DSR 4550 The GigE Default Gateway is an address that is represented in the common dotted decimal format Contact the network administrator for details about configuring ...

Страница 59: ... the field The MPTS Address range is from 000 000 000 000 to 255 255 255 255 Use the 4 buttons to select the digit to change and then while the cursor is on that digit press the buttons to display the desired value Repeat this process for each applicable digit to be changed Press the ENTER button to confirm the selection and exit the field Port Field Press the 4 button until the cursor is at the P...

Страница 60: ...eturn to the main top level menu shown below Press the 4 buttons until the cursor is at the Status label and press the ENTER button The DSR 4550 displays the first sub menu within the Status menus Status1 Menu Press the buttons until the Status1 menu appears shown below FrontPanel Field Default Local Control The Front Panel field indicates whether the user is able to control the IRD completely fro...

Страница 61: ...he range is 0000 to 4095 Four dashes are displayed when no information is available Quality Field The Quality field displays a number from 1 to 100 indicating the level of the signal quality If the signal is 50 or less it is marginal If it is 35 or less take action to increase the dish size or improve the reception by the LNB to prevent occasional loss of output Note The signal quality is also dis...

Страница 62: ...itially set in the Manual Tune menu Three dashes are displayed when no information is available or that the ASI input is in use Symb Field This field displays the symbol rate megasymbols per second of the L band signal based on the received signal Three dashes indicate that no information is available or when the ASI input is in use Code Field This field displays the code rate error control coding...

Страница 63: ...rmation is available Eb No Field This field displays the Signal to Noise Ration Eb No for the active L band signal Three dashes indicate that no information is available Authorize State Field This field displays the authorization state either Authorized or Not Authorized If the Authorization State is shown as Not Authorized the field alternately flashes and displays the reason why it is not author...

Страница 64: ... s IP Data Isochronous Data and Asynchronous Data IP Data Field This status only field indicates either Undefined or Defined whether the Program Map Table PMT for the current service contains an entry for a DSM CC component Isoc Data Field This status only field indicates either Undefined or Defined whether the Program Map Table PMT for the current service contains an entry for an isochronous data...

Страница 65: ...is at the Diag label and press the ENTER button The DSR 4550 displays the first sub menu within the Diagnostics menus Diagnostics Menu Press the buttons until the Diagnostics menu appears shown below Menus Field The Menus field allows the user to enable or disable the on screen diagnostics to a video monitor connected to the rear of the IRD Note For more information on the diagnostic screens refer...

Страница 66: ... specific DSR 4550 for authorization and to retune messages The display enables the user to view the address from the front panel rather than reading the label on the back panel Press the buttons until the Unit Address menu appears shown below TVPass Card Menu The DSR 4550 does not initially require a TV Pass Card but if one is required the program provider typically supplies one The program provi...

Страница 67: ...to display the three test options Off 1000 Hz at 16 dBm 4040 Hz and 3960 Hz at 4 dBm To terminate an audio test signal use the buttons to select Off and press the ENTER button or exit the L1 R1 field L2 R2 Field Default Off Caution Audio output to the customers may be interrupted and test signals override any active service component This field allows the user to enable the Audio 2 test signal Pre...

Страница 68: ...at the current video display will be interrupted if the action proceeds Press any arrow button 4 to back out of the field and leave it unchanged Otherwise press the ENTER button to proceed Note Test signals override any active service component and the DSR 4550 displays diagnostics over the video test patterns if diagnostics are enabled To disable the selected signals use the buttons to select Off...

Страница 69: ... press the ENTER button to move into the field Press the buttons to display the options Choose from the options listed in Table 3 2 Table 3 2 NTSC PAL M VITS Field Options The Transmitted option indicates the signal is provided over the satellite link by the programmer if one is present Press the ENTER button to confirm the selection Note If the Waveform option is neither Transmitted or Disabled t...

Страница 70: ...ton to move into the field Press the buttons to select the desired option Field 1 or Field 2 and press the ENTER button to confirm the selection and exit the field Line Field Default 17 Note The IRD does not display this field when the waveform is set to Transmitted or Disabled Press the 4 button until the cursor is at the Line label and press the ENTER button to move into the field Press the butt...

Страница 71: ...d Default Off The Cue Tone field lets the user turn the cue tone test ON and OFF Press the 4 button until the cursor is at the Cue Tone label and press the ENTER button to move into the field Press the buttons to display the options On or Off If On is selected the DSR 4550 generates a Dual Tone Multi Frequency DTMF code 0 9 ABCD on the cue tone output This test keeps repeating until the Off option...

Страница 72: ......

Страница 73: ...lity or low audio level Audio levels incorrect Adjust audio levels See Audio1 Gain and Audio2 Gain Menus on page 26 No video or Bypass Video is present Unit is in bypass mode Change to an available channel See Channel Menus on page 37 No audio or Bypass Audio is present Unit is in bypass mode Change to an available channel See Channel Menus on page 37 Will not acquire Port not configured Check por...

Страница 74: ......

Страница 75: ...MHz Downlink Frequency Formula for converting a C band Frequency to an L band Frequency Example calculation if downlink frequency is 3 740 MHz 5 150 MHz minus Frequency Downlink DL equals Frequency L band 5 150 MHz 3 740 MHz 1 410 MHz Table 5 2 Calculation for Ku Band Transponders Using 12 019 MHz Downlink Frequency Formula for converting a Ku band Frequency to an L band Frequency Example calculat...

Страница 76: ......

Страница 77: ...pport for All Products excluding Commercial Digital Satellite Receivers PRESS 1 Technical Training PRESS 3 Commercial Digital Satellite Receivers PRESS 2 https businessonline motorola com Technical Support Telephone Menu Options Issued 11 2008 888 944 HELP 847 725 4011 Severity Level 1 Critical Failure 2 Major Failure 3 Minor Failure 4 Lesser Failure Critical Issues PRESS ...

Страница 78: ...the unit for repair The RSA number must be prominently displayed on all equipment cartons and shipping label World Wide Digital is open from 8 00 AM to 5 00 PM Central Time Monday through Friday When shipping equipment for repair follow these steps 1 Pack the unit securely 2 Enclose a note describing the exact problem 3 Enclose a copy of the invoice to verify the warranty status 4 Label all carton...

Страница 79: ...rabic ara Egyptian egy Armenian arm English eng Balinese ban Esperanto epo Basque Baq Faroese fao Batak Indonesian btk Finnish fin Bengali ben French fre Bhojpuri bho German ger Bulgarian bul Greek gre Burmese bur Gujarati guj Catalan cat Hebrew heb Chinese chi Hindi hin Croatian scr Hiri Motu hmo Cue Tones cue Hungarian hun Czech cze Indonesian ind Danish dan Interlingua ina Dutch dut Iranian ira...

Страница 80: ...oan smo Kurdish kur Scots sco Latin lat Sindhi snd Malay may Spanish spa Mandar mdr Swahili swa Marathi mar Swedish swe Miscellaneous mis Tagalog tgl Mongolian mon Tamil tam Nepali nep Thai tha Norwegian nor Urdu urd Otomian Lang oto Vietnamese vie Pahlavi pal Welsh wel Persian per Language Abbreviation Language Abbreviation ...

Страница 81: ...s otherwise noted Information about these screens is described here for documentation purposes only Notes 1 Hexadecimal numbers are displayed with none or more leading zeros 0 to pad to their individual field width 2 Decimal numbers are right justified in their individual display rectangle and are not padded with leading zeros 0 3 Decimal numbers may be displayed without or with a trailing decimal...

Страница 82: ...cursor is on the Menus option allows access to the OSD diagnostic screens Use the buttons on the front of the IRD to navigate between the Fast Fact Diagnostic screens while displaying the data to the OSD Note Pressing the ENTER button on the front of the IRD while viewing a particular OSD diagnostic screen allows for the continued display of the OSD diagnostic information while allowing the user t...

Страница 83: ...ortant audio information and the fifth screens shows the Ethernet configuration Fast Facts 1 The Fast Facts 1 screen displays general information relating to the basic functionality of the IRD Field Name Definition Unit Factory set 16 digit Unit Address for the IRD VC Shows the virtual channel number Firmware Shows the firmware version in the boot sector of ROM and the application section Unit 225...

Страница 84: ...d to a signal or not Sat Xpndr Displays the satellite name and transponder number If the sat ellite name is null then the satellite number is used Signal Strength Displays the signal strength for the currently tuned to satellite and transponder This value is normalized to be between 0 and 100 Polarization Shows the polarization for the currently tuned to transponder either Horz Horizontal Vert Ver...

Страница 85: ...t is Inactive Satellite Name The name of the current satellite Polarization The polarity transponder associated with the port either Horz Horizontal Vert Vertical Configuration Status The configuration status of the port either Defined Undefined or Not Supported A B E Port 0 S1 Horz Defined Port 1 T6 Vert Defined Port 2 Undefined Port 3 Undefined Port 4 Undefined Fast Facts 2 Port 5 Undefined Port...

Страница 86: ...rrent output format of the video display Video PID The current Program Identification PID number for the Video Window The current dimensions of the video display Width x Height Xpos Ypos or mute PCR Pid The current Program Clock Reference PCR PID Aspect Mode The current aspect mode for the incoming video Source Format The source format Interlaced or Progressive Video Setup Indication if the video ...

Страница 87: ...C Video Mute Control The current video mute count Frame Rate The frame rate code of the stream PTS FIFO The video Presentation Time Stamp PTS followed by the Pic ture FIFO Depth Count Chroma Ratio The Chrominance format for the video within the transport stream Video Rate The rate in Mbps of the video within the transport stream SDI Indicates whether or not the SDI input is enabled or disabled Fie...

Страница 88: ...s not being received Audio Pid The current Audio PID for both audio programs PCR Pid The current PCR PID for both audio programs Type The audio stream type MPEG AAC AC3 etc Sample Rate The sampling rate in kHz of both audio programs Audio Mix The audio processing mode for both audio programs Mono Stereo Surround etc Language Preference The preferred language setting for both audio programs Languag...

Страница 89: ...finition Network Status Provides the status of the 10 100 Ethernet port e g Link Down Half Duplex Full Duplex and Link Unknown Address Type The Address Type of the unit MAC Address The MAC Address of the unit IP Address The IP Address of the unit Subnet Mask The Subnet Mask of the unit Gateway The Gateway Address of the unit A B C D E F A B C D E F ...

Страница 90: ...he GiGE Ethernet e g Link Down Half Duplex Full Duplex and Link Unknown MAC Address MAC Address of the GiGE ethernet IP Address IP address of the GiGE ethernet Subnet Mask Subnet mask of the GiGE ethernet Gateway Gateway of the GiGE ethernet Dest IP Address Destination IP address Dest Port Destination port Output Mode Displays the output mode for the GiGE Ethernet port A B C D E F G H A B C D E F ...

Страница 91: ...urn Loss 8 dB minimum Port to Port Isolation 40 dB minimum Video Analog Frequency Response 0 9 dB 1 kHz to 4 2 MHz NTSC 0 9 dB 1 kHz to 4 8 MHz PAL 0 1 5 dB 4 8 MHz to 5 5 MHz PAL Video Level 1 0V p p 10 Chrominance Luminance Delay Inequality 40 nsec Differential Gain 4 5 p p maximum 10 to 90 APL Differential Phase 4 5 p p maximum 10 to 90 APL ...

Страница 92: ... picoseconds maximum Transmission Standard DCII Symbol Rates 3 25 to 29 27 Msps DCII Code Rates 5 11 1 2 3 5 2 3 3 4 4 5 5 6 and 7 8 Audio Analog Output Level 16 0 dBm 1 0 dB into 600 Ohms attenuation adjustable 0 to 15 dB Frequency Response 1 0 dB 20 Hz to 20 kHz Total Harmonic Distortion 1 25 dB pp or better at 1 kHz RE 10 dBm 20 Hz to 20 kHz S N 85 dB or better at 1 kHz RE 16 dBm measured at 20...

Страница 93: ...dB relative to 0 dB 16 dBm in and 16 0 dB out 1 kHz S N 86 2 dB min 1 kHz referenced to 16 1 dBm encoder input measure in a 20 Hz to 20 kHz bandwidth with all video outputs terminated Lip Sync Delay 20 msec for all video inputs IP Data Rate DSM CC IP Data Rate 47 1 Mbps Electrical Power Requirements AC 100 240V 50 60 Hz 60W LNB Power Supply 19 to 21 V minimum 480 mA loaded Connectors RF In F type ...

Страница 94: ...Screw terminal Qty 1 AUX Audio In Screw terminal Qty 1 Audio Out Primary and Secondary Screw terminal Qty 2 ISOC Data Screw terminal Qty 1 Contact Closure Labeled Relay 1 2 and 3 Screw terminal Qty 3 ASI In BNC connector Qty 1 ASI Out BNC connector Qty 1 SDI Out Digital Video BNC connector Qty 1 Digital Audio Out BNC connector Qty 2 Mechanical Dimensions H 3 1 4 4 cm W 19 0 48 3 cm D 20 50 52 cm W...

Страница 95: ...contato com o Serviço ao Cliente da Motorola para obter assistência Caring for the Environment by Recycling When you see this symbol on a Motorola p do not dispose of the product with residentia commercial waste roduct l or uthorities enbrug tte symbol på et Motorola produkt Genbrug af dit Motorola Recycling your Motorola Equipment Please do not dispose of this product with your residential or com...

Страница 96: ......

Страница 97: ......

Страница 98: ...6450 Sequence Dr San Diego CA 92121 Document No 540038 001 Rev F 540038 001 99 PLEASE RECYCLE ...