4 DIAGNOSTICS
40
The Code Modules fields are:
Field Description
Boot Code
The boot code version in ASCII format
Version
The firmware version and build date in ASCII format
Digital Secure
Processor
The digital secure processor version in ASCII format
Analog
Secure
Processor
The analog secure processor version in ASCII format
Downloadable
Object
Information
Table
Lists all objects loaded, or being loaded, onto the DCH3416 in ASCII format. The
information displayed for each object depends on the running environment. If a
download is not in progress, the front panel displays the currently running environment
and version number, as shown in Figure 4-9. On the front panel, “bPC” represents Thin
Client code.
Object
The object name
Ver
The object version
Status
The object status, updated on the OSD and front panel every 5 seconds while you
display the diagnostic:
OSD
Status
Description
MEM ALLOC
Allocated
Memory for object is allocated
LOADING
Loading
Object is being loaded
STARTING
Enabling
Object is being started (the constructor
is running)
ENABLED
Enabled
Object is running
ENA-NOT RUN
Enabled_Not_ Runnable
Object is enabled, but cannot run
STOPPING
Disabling
Object is being stopped (the destructor
is running)
DISABLED
Disabled Object has been disabled
DIS-NOT RUN
Disabled_Not_ Runnable
Object is disabled and cannot run
DELETING
Deleting
Object is being deleted
POSTPONED
Postponed
Object cannot run on the current
system; it will be enabled during the
next boot
CONNECTED
Connect
Connected to download PID — awaiting
data
PEND CONNECT
TryingToConnect
Trying to connect
ID
The object identifier