Power On Self-Tests
6-4
6
AMIBIOS displayed error messages
The following section describes the operation of the CPV5000 when the BIOS
detects an error during power up of the CPV5000. The explanation assumes
that a copy of AMI diagnostics is available to assist with debug of the problem.
If an error occurs after the system display initializes, error messages are
displayed as follows:
ERROR Message Line 1
If this message appears, press <F1> to continue.
The following message may also appear:
RUN SETUP UTILITY.
Press <F1> to run WINBIOS Setup if this message appears. Refer to Table 6-
3 for AMIBIOS displayed error message information.
Table 6-3. AMIBIOS error messages
Message
Explanation
8042 Gate-A20 error
Gate A20 on the keyboard controller (8042) is not working. Replace the
8042.
Address line short!
Error in the address decoding circuitry
C: drive error
No response from drive C:. Run the AMIDiag hard disk utility. Check
the C: hard disk type in Standard Setup.
C: drive failure
No response from hard disk drive C:. Replace the drive.
Cache memory bad,
Do not enable cache
Cache memory is defective. Run AMIDiag.
CH-2 timer error
An AT system has two timers. There is an error in timer 2.
CMOS battery state
low
CMOS RAM is powered by a battery. The battery power is low. Replace
the battery.
CMOS checksum
failure
CMOS RAM checksum is different than the previous value. Run
WINBIOS Setup.
CMOS system options
not set
The values stored in CMOS RAM are destroyed. Run WINBIOS Setup.
Содержание CPV5000
Страница 1: ...CPV5000 CompactPCI Single Board Computer Installation and Reference Guide CPV5000A IH3 ...
Страница 16: ...xvi ...
Страница 22: ...CPV5000 Single Board Computer Overview 1 6 1 ...
Страница 26: ...Getting Started 2 4 2 Figure 2 1 Installing the CPV5000 ...
Страница 80: ...Functional Description 4 24 4 ...
Страница 108: ...Power On Self Tests 6 18 6 ...
Страница 144: ......