3. Insert the hard drive all the way into the recorder then push the handle against the hard drive to lock it
into place.
4. Open the Server Administrator application and expand the System Tree.
The new hard drive should be automatically added to the Physical Disks list. The list is typically
available here:
System > Storage > PERC H730P > Connector 0 (RAID) > Enclosure (Backplane) >
Physical Disks
.
5. Assign a task to the new hard drive or allow it to exist as an extra storage drive.
It is recommended to use the new hard drive as a hot spare. Hot spares are hard drives that are
available on standby in the event of a hard drive failure in the RAID. If that occurs, you can configure
the system to automatically redirect recording to the unused hard drive.
To assign the new hard drive as a hot spare:
a. In the Task list, select
Assign and Unassign Global Hot Spare
.
b. Click
Execute
.
If the new hard drive is not displayed in the Server Administrator, try one of the following:
l
Refresh the browser.
l
Reboot the recorder.
Replacing Front or Back Hard Drives
1. Locate the failed hard drive at the front or back of the recorder.
2. Press the release button on the front left of the hard drive.
3. When the handle is released, pull the hard drive out of the recorder.
4. Remove the four screws from the side of the hard drive carrier.
5. Lift the failed hard drive out of the carrier.
6. Insert a new hard drive into the carrier then screw it into place. The hard drive connectors should face
the back.
Replacing Front or Back Hard Drives
11