Country-Specific Information C-25
C
ountry-S
pe
cif
ic
Information
Finland—Delayed Call Lists
The modem processes call attempt failures as delayed calls, according to PTT
regulations. Before dialing a number, the modem determines whether:
• The number is on the delayed list
• The delayed list is full (the list holds 16 numbers)
In either case, the number is not dialed. When the modem is turned off and then on
again, the lists are cleared, and the numbers can be dialed.
After dialing, the modem processes the following call failures as delayed calls:
• The modem receives a busy tone after dialing a call
• The call is not answered within the time in the Call Timeout (AT
*
TT) option
For these call failure conditions, four subsequent redial attempts are allowed. If the
redial call attempts are unsuccessful after a total of five calls, within one hour, the
number is placed on the delayed list. Then it cannot be dialed for 60 minutes. After
60 minutes, the number is available for dialing.
France—Delayed and Forbidden Call Lists
The modem processes call attempt failures as delayed and forbidden calls, according
to PTT regulations. Before dialing a number, the modem determines whether:
• The number is on the delayed or forbidden list
• The delayed or forbidden lists are full (the list holds 16 numbers)
In either case, the number is not dialed. When the modem is turned off and then on
again, the lists are cleared, and the numbers can be dialed.
The following criteria determine on which list the number is placed:
• Delayed List. The modem detects one of the following “delay conditions:”
— The modem receives a busy tone after dialing a call
— The call is not answered within the time in the Call Timeout (AT
*
TT)
option
If one or both of these conditions is detected for six consecutive calls, the
number is placed on the delayed list. Then it cannot be dialed for 60 minutes.
After 60 minutes, the number is available for dialing.
• Forbidden List. The modem detects a “forbidden condition:”
— A call is dialed by the modem, and answered by a remote modem, but an
Answer Back Tone (ABT) is not detected by the calling modem
— A call is manually aborted via the front panel or the V.25 bis ACU
If the modem detects two occurrences of a forbidden condition for a number
within a 2-minute period, the number is placed on the forbidden list and no
calls are allowed to this number. If the call is successfully dialed within the
Содержание 3260
Страница 1: ...RD TR RI OH TD CD RC NC 3260 12 Motorola 326X V 34 V 34 SDC and V 32bis Series Modem User s Guide 34 ...
Страница 10: ...x Contents continued ...
Страница 18: ...xviii Using the Documentation Set continued ...
Страница 22: ...xxii Motorola ISG Customer Information continued ...
Страница 34: ...1 10 About the Modem About the Modem ...
Страница 50: ...2 16 Installing the Modem Installing the Modem ...
Страница 62: ......
Страница 73: ...Configuring the Modem 4 11 Configuring the Modem 5 Do not turn off modem power until SAVE COMPLETED appears ...
Страница 92: ...4 30 Configuring the Modem Configuring the Modem ...
Страница 122: ......
Страница 168: ......
Страница 180: ......
Страница 226: ...C 46 Country Specific Information Country Specific Information ...