Version 1.5
© Openpath 2021
16
Figure 7 SDC Port LED descriptions
RESETTING THE SDC
SOFT RESET
To soft reset the SDC, disconnect power from the SDC, wait 10 seconds, then
reconnect the power.
HARD RESET
WARNING:
Only hard reset the SDC if absolutely necessary and if instructed by
Openpath. This will clear all of the data off of the SDCand will require
reprovisioning.
To hard reset the SDC:
1. Disconnect power from the SDC
2. Hold down the ADMIN button for 15 seconds (see
3. While still holding down the ADMIN button, reconnect the power, and continue to
hold the button for another 15 seconds until the Status LED turns yellow, then
release
4. Wait until the Status LED turns blue before
LEGACY WIRING
Sometimes legacy wiring (unshielded and straight through, rather than shielded
twisted pair, often 22-6) results in slower connections and dropped packets between
the Openpath Reader and SDC. To remedy this, you can switch GND and VIN with +B
and -A connections on the SDC and readers to ensure the data pair (+B and -A) are
using the alternate pair of legacy wires.