background image

 

Rev. 1.0      10/07/09 

MC7 

Electronic Control Unit 

Electronic  control  unit  for  the  automation  of  a  projection 
screen, with MX14 Radio current sensor functioning. 

T

ECHNICAL 

D

ATA

 

- Power supply: 

230V~  50/60Hz  600W max. 

- Motor output: 

230V~  500W Max. 

- Working temperature: 

-10 55°C 

- Narrow band radio receiver:                              433.92  MHz 
- Compatible radio-controls: 

MX14  

– Rolling Code 

- Amount of Radio-controls that can be memorised:    14 Max.                      
- Board dimensions:                                      65 x 40 x 25 mm. 
 

C

ONNECTIONS OF THE 

CN1

 

T

ERMINAL BOARD

 

1:  Earth connection input. 
2:  Earth connection input. 
3:  230V~ Line input (Phase). 
4:  230V~ Line input (Neutral). 
5:  Ascent Motor Output. 
6:  Common Motor Output. 
7:  Descent Motor Output. 

 

I

NITIAL 

F

UNCTIONING 

C

ONDITION

 

The device can only work coupled with one or more MX14 Ra-
dio current sensor. 
Upon first ignition, the control unit does not contain any Radio 
current sensor code in the memory. 

F

UNCTIONING WITH 

R

ADIO 

C

URRENT 

S

ENSOR

 

The  control  unit  used  coupled  with  the  MX14  Radio  current 
sensor  will  allow  to  manage  distinct  controls,  the  first  for  the 
Descent until time expires (when the controlled projector is on) 
and the second for the ascent until time expires (when the con-
trolled projector is off or in stand by ) of the projection screen. 

 

P

ROGRAMMING 

K

EYS AND 

I

NDICATOR 

LED 

SEL Key

: selects the type of function to memorise, the choice 

is indicated by the flashing of the LED. By repeatedly pressing 
the  key,  it  is  possible  to  position  oneself  on the desired func-
tion.  The  selection  remains  active  for  15  seconds,  displayed 
by the flashing LED, after which the control unit returns to the 
original status. 

SET Key

: carries out the programming of the function chosen 

with the SEL key. 

Indicator LED

 

LED on: option memorised. 
LED off: option not memorised. 
LED flashing: option selected. 

---------------------- MAIN MENU -----------------

 

LED Reference          LED Off                        LED On 

1) CODE              No code                   Pgm. code 
2) MOT. T.           Motor time 3 min.         Pgm. Motor Time 

 

 

 

 

 

 

 

 

 

 

 

 

1)  CODE 

(Programming  of  the  MX14  Radio  current  sensor 

to function the Projection screen)

 

 
Programming of the MX14 current sensor:

 

The programming of the transmission codes of the  MX14 Ra-
dio current sensor is carried out as follows: press the SEL key, 
CODE LED will start to flash, simultaneously send the chosen 
code  of  the  MX14  Radio  current  sensor:  the  CODE  LED  will 
remain on and the programming will be complete. If no code is 
sent within 10 seconds, the control unit exits the programming 
phase.  In  case  all  14  available  codes  have  been  memorised, 
by  repeating  the  programming  operation,  all  indicator  LEDs 
will  start  to  flash  very  fast,  indicating  that  further  memorising 
is not possible. 

 
Deletion: 

The deletion of all memorised codes for the functioning of the 
Projection  screen  control  unit  is  carried  out  as  follows:  press 
the  SEL  key,  the  CODE  LED  will  start  to  flash,  subsequently 
press the SET key, the CODE LED will switch off and the pro-
cedure will be complete. 

2)  MOT. T. 

(Motor Time Programming max 4 minutes)

 

The  control  unit  is  provided  with  motor  power  time  equal  to 
three minutes (LED T.MOT. OFF). 
The  programming  of  the  motor  time  must  be  carried out with 
fastening down as follows: 
Position  yourself  with  SEL  key  on  flashing  of  MOT.  T.  LED 
and  press  the  SET  key  continuously,  the  Screen  for  projec-
tions  will  start  Descent,  upon  reaching  the  wanted  point,  re-
lease the SET key. At this point the memorisation of the motor 
time  will  be  determined  and  the  MOT.  T.  LED  will  remain 
switched  on.  In  case  of  wanting  an  infinite  motor  time, follow 
the  same  programming  procedure,  keeping  the  SET  key 
pressed  continuously  for  less  than  two  seconds  the  MOT.  T. 
LED. IT IS possible to repeat the operation in case of incorrect 
programming. 

R

ESET

 

In case it is necessary to reset the control unit default factory 
configuration, press the SEL and SET keys together so that all 
indicator LED switch on and off at the same time. 

 
 

 

 

GB

 

Отзывы: