04. INSTALLATION

AUTOMATISM INSTALLATION

MICROS ADJUSTMENT

04. INSTALLATION

1 • Place the motor on the support plate and 

fix it with supplied M8 screws.

The arms are supplied already assembled.

• 

If you install only one motor and the arm is not in 

the correct position, you can easily change the direc-

tion following the indications in the picture

 Fig. 13

.

1 • Mount the square hole in the motor's output shaft, and tighten with provided washer and M10x20 

screw.  2 • Place the other  extremity of the arm under the gate support, and secure with screw, bushing, 

washer, and female.

1 • Unlock the automation and open the door leaf to the desired position.

2 • Loosen 

(A)

 the 

opening ring screw

, and turn it

 (B)

 until you hear a *click* of the micro switch.

3 • Tighten the screw 

(C)

 of the ring to lock it in this position.

ARMS INSTALLATION

Remove the automation's 

cover. To do this, loosen the 

two front screws, slightly tilt 

the cover back and pull up.

After the installation is complete, make all the electrical connections and replace the cover.

Fig. 11

Fig. 14

Fig. 12

Fig. 13

Fig. 16

Fig. 17

Fig. 18

4 • Close the door leaf, loosen 

(A)

 and turn 

(B)

 the 

closing ring 

until it makes  a *click* into the corres-

ponding micro. Retighten 

(C) 

the ring screw.

5 • Manually test the opening and closing of the gate 

to ensure that the micro switches are activated in 

the correct point. 6 • When the micros are tuned, re-

-lock the automation.

Fig. 19

Fig. 20

Fig. 21

Fig. 22

Fig. 15

Содержание TELICA

Страница 1: ...V3 2 REV 05 2020 TELICA EN USER S AND INSTALLER S MANUAL...

Страница 2: ...ystems This marking on the product or literature indicates that the product and electronic accessories eg Charger USB cable electronic material controls etc should not be disposed of as other househol...

Страница 3: ...perienced in terms of usage of the product in a safe manner and who understands the risks and dangers involved Children shouldn t play with the product or opening devices to avoid the motorized door o...

Страница 4: ...all safety conditions have been met In the event of tripping of circuits breakers of fuse failure locate the malfunction and solve it before resetting the circuit breaker or replacing the fuse If the...

Страница 5: ...230V Power supply 24Vdc 230Vac Power 220W 380W Force 200 Nm Working frequence Intensive Use 50 Capacitor 12 5 F Protection grade IP54 Noise LpA 50dB A Thermal protection 120 C Operating temperature 2...

Страница 6: ...r malfunction Fig 5 To unlock insert the unlock key into the automation front hole and turn it on clockwise 4 5 times until you feel a limit To lock Rode a chave no sentido contr rio at sentir um ob s...

Страница 7: ...ion and open the door leaf to the desired position 2 Loosen A the opening ring screw and turn it B until you hear a click of the micro switch 3 Tighten the screw C of the ring to lock it in this posit...

Страница 8: ...echanical stoppers in the opening and closing position of the gate If not respected components of the automation may suffer efforts for which they were not prepared and as a result will be damaged It...

Страница 9: ...it is possible to understand if the automatism can function properly connected directly to the current You should use a new capacitor during this test to ensure that the problem does not lie on it 1 C...

Страница 10: ...al systems NOTES To make these tests it isn t necessary to remove it from the location where it is installed be cause in this way you can understand of the automatism works properly directly connected...

Страница 11: ...de which devices are with anomalies All safety devices LEDs DS in normal situations remain On All START circuits LEDs in normal situations remain Off If LEDs devices are not all On there is some secur...

Страница 12: ...tor 2 Motor 2 starts closing before Motor 1 It must be applied an 8 capacitor in each motor on the opening and closing wires as explained above NOTE If any one of the motors moves in the wrong way jus...

Страница 13: ...C2 230Vac 2Ah 115Vac 3Ah N0 N0 EN 09 CONNECTION SCHEME Complete opening Partial opening Flashing light 12 24VD 4W M x Transformer 230Vac or 110Vac 5 0 60Hz 120W M x Solar Panel Electric lock 12 24VDC...

Отзывы: