background image

6A

6B

Ø10,5

90º

W

NC

COM

M

Z

90º

9

10

11

12

13

5A

5B

EN

EN

02. THE AUTOMATISM

INSTALLATION INSTRUCTIONS

20 • Rotate the plastic washer (Q1) by hand until you hear the click of the microswitch 

1 (down regulation completed).

21 • Rotate the other plastic washer (Q2) towards the microswitch 2 (up). Give tension 

to the motor through an electric command and verify if the shutter, climbing, stops in 

desired point. Adjustments of the position can be effected acting always on the same 

plastic washer and operating through electric command.
22 • Should the shutter need to be installed contrary to the description in figure 2, the 

steps described above should be carried out to the contrary as microswitch 2 will stop 

the closing and microswitch 1 will stop the opening.

23 • Fasten the counternuts after adjusting the limit-switch washers.

INSTALLATION OF THE ELECTROBRAKE

01 • Insert the brake on the back of the electrical motor.
02 • Fixing the electrobrake to the motor using the screws M5x50.
03 • Remove the bridge from the limit switch (fig. 9).

Do not damage the bridge pulling on the wire and keep it for future use.
04
 • Connect the electric cables of the brake to the terminal of the limit switch, figure 4.
05 • Close the limit switch using the plastic cover.

02. THE AUTOMATISM

GEAR MOTOR  WITH SAFETY DEVICE

03 • The downward run of the roller shutter 

shall ben consistent with the downward 

run of the safety brake. Place the gear 

motor as shown.

04 • For microswitch versions, connect the 

micro switch’s cable (W) in series to the fee 

ding cable (common) of the gearmotor.

02 • After assembled the two elements of 

the gearmotor (G), check that the pawl (Z)

is in the highest position perpendicular to 

the rolling shutter axis.

Gear motor with safety device carried out to the stop the free fall of roller shutters and at 

the same time, in microswitch versions, to interrupt the motoreductor’s feeding.

01 • Effect on the tube of the shutter a pas

sing perforation Ø10 perpendicular to the 

axis.

Motor

 Electrobrake

Capacitor

Switch

Power supply

230V

Shunt

Отзывы: