04. DIP SWITCH
DIP SWITCH CONFIGURATION
485 A (blue)
+12V (red)
GND (black)
485 B (yellow)
Secure the rear plate to the wall using the wall
mounting screws. (Use suitable dowels for this
purpose).
Secure the MPXR92MSK
and the rear plate using a
star-shaped screw.
BOTTOM VIEW
Mount the MPXR92MSK
terminal on the rear plate.
1
2
3
In order for the control centre to be able to identify the task of each of the interconnected readers in an
access control system, each of these devices must have a unique identification ID.
This ID is crucial to identify the task that each device performs and which port/access is installed.
The definition is made through the existing dip switch frame on the back of each reader, according to
the following table:
If you connect two or more devices with the same ID in a central, it will create a communication
conflict and none will work correctly.
ID
Dip switch
Door
Function
No ID
ON
1 2 3 4 5 6
-
-
1
ON
1 2 3 4 5 6
Door 1
Entry
2
ON
1 2 3 4 5 6
Exit
3
ON
1 2 3 4 5 6
Door 2
Entry
4
ON
1 2 3 4 5 6
Exit
5
ON
1 2 3 4 5 6
Door 3
Entry
6
ON
1 2 3 4 5 6
Exit
7
ON
1 2 3 4 5 6
Door 4
Entry
8
ON
1 2 3 4 5 6
Exit
RS485 output and power input:
CABLES DESCRIPTION
03. INSTALLATION
INSTALLATION OF WALL-MOUNT