• Power Supply

12V DC 1A

• Current

200mA (max)

• IP

IP65

• Communication

 RS485

• Keyboard

Numeric(0-9, * , #)

• Card Reading Format

Mifare (13.56 MHz)

• Read Range

3-5 cm

• ID Setting

DIP Switch

• Operating Temperature

-25°C a 55°C

• Operating Humidity

20% ~ 80%

• Dimension

77x120x22mm (LxAxP)

Reader for external use with backlit numeric keypad that is part of the control and access management 

of a given location.

TECHNICAL CHARACTERISTICS

BASIC CONTENT

01

 • 01 MPXR92MSK

02 

• 01 Metallic Rear Plate

03

 • 02 Screw for fixing to the wall

04

 • 01 Mounting plate screw

05

 • 01 Hex Key

06

 • 01 Cable

CLOSE DOOR

CHECKS THE ACCESS 

CODE

EVENTS LOG

ST

ORED

IDENTIFICATION

MRAC

(CONTROL BOARD)

REGISTER CARD OR

ACCESS CODE

REGISTRATION IN THE

SOFTWARE MANAGEMENT

VERIFICATION 

FAILED

Please try again!

CREA

TE

OPEN DOOR

ACCESS CODE 

DATA BASE

SUCCESSFULLY

VERIFIED

Thank you

02. PRODUCT

02. PRODUCT

PRODUCT DESCRIPTION

OPERATING SHCEME

Содержание MPXR92MSK

Страница 1: ...V1 0 REV 02 2021 MPXR92MSK MPXR92MSK EN USER INSTALLER MANUAL ...

Страница 2: ...t or literature indicates that the product and electronic accessories eg Charger USB cable electronic material controls etc should not be disposed of as other household waste at the end of its useful life To avoid possible harm to the environment or human health resulting from the uncontrolled disposal of waste separate these items from other types of waste and recycle them responsibly to promote ...

Страница 3: ...ienced in terms of usage of the product in a safe manner and who understands the risks and dangers involved Children shouldn t play with the product or opening devices to avoid the motorized door or gate from being triggered involuntarily WARNINGS FOR TECHNICIANS Before beginning the installation procedures make sure that you have all the devices and materials necessary to complete the installatio...

Страница 4: ...automatism turn off the power and do not use it until all safety conditions have been met In the event of tripping of circuits breakers of fuse failure locate the malfunction and solve it before resetting the circuit breaker or replacing the fuse If the malfunction is not repairable by consult this manual contact a technician Keep the operation area of the motorized gate free while the gate in in ...

Страница 5: ...it numeric keypad that is part of the control and access management of a given location TECHNICAL CHARACTERISTICS BASIC CONTENT 01 01 MPXR92MSK 02 01 Metallic Rear Plate 03 02 Screw for fixing to the wall 04 01 Mounting plate screw 05 01 Hex Key 06 01 Cable CLOSE DOOR CHECKS THE ACCESS CODE EVENTS LOG STORED IDENTIFICATION MRAC CONTROL BOARD REGISTER CARD OR ACCESS CODE REGISTRATION IN THE SOFTWAR...

Страница 6: ...LED 14 Pin Conectors RS485 Power Supply Input ID Setting Case button On the back of the mounting plate Numeric keyboard and MIFARE Card Area Star shaped screw hole to secure the reader to the rear plate REAR PLATE FRONT BOTTOM SIDE BACK 02 PRODUCT DIMENSIONS AND PRODUCT DIAGRAM ...

Страница 7: ... unique identification ID This ID is crucial to identify the task that each device performs and which port access is installed The definition is made through the existing dip switch frame on the back of each reader according to the following table If you connect two or more devices with the same ID in a central it will create a communication conflict and none will work correctly ID Dip switch Door...

Страница 8: ...OL BOARD 05 CONNECTION SCHEME EXTERNAL POWER CONNECTION 12Vdc Red 12Vdc Red RS485 RXD Blue RS485 RXD Blue RS485 TXD Yellow RS485 TXD Yellow GND Black GND Black Recommended power supply 12Vdc 10 at least 500mA Comply with IEC EN 60950 1 standard To share power with other devices use a power supply with higher current ratings Nº PIN DESCRIPTION WIRE 1 12Vdc Red 2 GND Black FA3 MPXR92MSK MRAC MRAC CO...

Страница 9: ...se contact our technical support depart ment 07 TROUBLESHOOTING 06 COMPONENT TEST INSTRUCTIONS FOR FINAL CONSUMERS SPECIALIZED INSTALLERS DEVICE TEST To avoid self sensing interference from the touch sensor please do not touch the sensor when turning on the device power 1 When the power is on the reader will flash the green LED and hear the audible tone simultaneously 2 Place the supplied card clo...

Отзывы: