Motorline professional MC112PR Скачать руководство пользователя страница 8

7A

7B

22

RC

7

RA

21

RB

R/L1

S/L2

T/L3

U/T1

V/T2

W/T3

B2

+2/B1

DC+/+1

DC-

10

MI1

11

MI2

5

MI3

6

MI4

8

MI5

20

MI6

-

MI7

4

24

V

4

24V

12

DC

M

12

DC

M

-

DFM

16

10V

13

AC

M

14

AVI

15

AC

I

17

AFM

14

M01

15

M02

-

24V

9

S1

9

S2

15

DC

M

-

SG+

-

SG-

-

SGND

13

MC

M

R

G

B 12V

BR1

N

N

L

L

M1 M2 M3 OP C/P COM FAP FCH COM DS BL GND 24V BR2 E1

E1

EN

EN

R/L1

 • 230Vac Power Supply

S/L2

 • 230Vac Power Supply

U/T1 

• Motor output – Phase 1

V/T2 

• Motor output – Phase 2

W/T3 

• Motor output – Phase 3

T/L3 

• 

Not used

       

 Ground

DC-

 • 

Not used

DC+/+1 

• 

Not used

+2/B1

 • Braking resistor connection

B2 

• Braking resistor connection

       

• 

Ground

FREQUENCY INVERTERS CONNECTIONS

CONNECTIONS CONNECTORS

The below panel ate all inputs and outputs of connection connectors.

The following panel are all inputs and 

outputs of frequency inverter.

24V

 • Common STOP

S1

 • STOP button

S2 

• STOP button

DCM 

• 

Not used

SG+

 • 

Not used

SG-

 • 

Not used

SGND 

• 

Not used

MCM 

• Voltage input for 

M01

 and 

M02

 outputs

10V

 • 

Not used

ACM

 • 

Not used

AVI 

• 

Not used

ACI 

• 

Not used

AFM

 • 

Not used

M01 

• Pulse output for MR13

M02 

• Output for optional interlocking relay or pre-flashing light.

Programmable at 

parameter 04.61

MI1

 • Opening button

MI2

 • Closing button

MI3 

• Limit switch

MI4 

• Limit switch

MI5

 • Photocells

MI6 

• STOP button

MI7 

• 

Not used

24V 

• Photocells and Radars Input (24Vdc 3W)

24V 

• Photocells and Radars Input (24Vdc 3W)

DCM

 • Negative output 24Vdc 3W

DCM 

• Negative output 24Vdc 3W

DFM 

• 

Not used

RA

 • NO relay output for electric brake

RB

 • 

Not used

RC 

• Common relay for electric brake

04. INVERTERS AND CONECTORS

04. INVERTERS AND CONECTORS

E1

 • 

Ground

M1

 • Motor output – Phase 1

M2

 • Motor output – Phase 2

M3

 • Motor output – Phase 3

OP

 • Opening button

C/P

 • Closing/Pedestrian Button

COM

 • Common

FAP

 • Opening limit switch

FCH

 • Closing limit switch

COM

 • Common

DS 

• Photocells input

BL

 • STOP

GND

 • 24V Negative

24V

 • Photocells and Radars Input (24Vdc 3W)

BR1

 • Output with fuse for electric brake (1A 250V fuse)

BR2

 • Electric brake

E1 

• 

Ground

N

 • 230Vac Power Supply

L

 • 230Vac Power Supply

DPN 16A circuit breaker

R

 • RED LED output

G

 • GREEN LED output

B

 • BLUE LED output

12V

 • 12Vdc 2W LED Power Supply

Содержание MC112PR

Страница 1: ...V3 0 REV 08 2022 MC112PR MC113PR MC114PR EN USER S AND INSTALLER S MANUAL...

Страница 2: ...estriction of the use of certain hazardous substances in electrical and electronic equipment Applicable in countries with recycling systems This marking on the product or literature indicates that the...

Страница 3: ...enced in terms of usage of the product in a safe manner and who understands the risks and dangers involved Children shouldn t play with the product or opening devices to avoid the motorized door or ga...

Страница 4: ...and do not use it until all safety conditions have been met In the event of tripping of circuits breakers of fuse failure locate the malfunction and solve it before resetting the circuit breaker or r...

Страница 5: ...llows easy and intuitive operation of various parameters and menus through a display It also has other functions such as Human Presence possibility to view the count of cycles carried out by the door...

Страница 6: ...g the operation LEDs LED 1 ON Indicates that it is being powered at 230Vac OFF No power LED 2 ON SEC contact closed OFF SEC contact open LED 3 ON STR contact closed OFF STR contact open LED 4 Programm...

Страница 7: ...24V 9 S1 9 S2 15 DCM SG SG SGND 13 MCM 22 RC 7 RA 21 RB R L1 S L2 T L3 U T1 V T2 W T3 B2 2 B1 DC 1 DC 10 MI1 11 MI2 5 MI3 6 MI4 8 MI5 20 MI6 MI7 4 24V 4 24V 12 DCM 12 DCM DFM 16 10V 13 ACM 14 AVI 15 A...

Страница 8: ...ACM Not used AVI Not used ACI Not used AFM Not used M01 Pulse output for MR13 M02 Output for optional interlocking relay or pre flashing light Programmable at parameter 04 61 MI1 Opening button MI2 Cl...

Страница 9: ...CM ON 1 2 ANT STR SEC 12 13 N L R G B 4 2 1 6 11 10 3 5 7 8 9 N F 10 8 9 3 4 5 2 1 7 20 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 M1 M2 M3 OP C P COM FAP FCH COM DS BL GND 24V...

Страница 10: ...13 MCM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 ON 1 2 ANT STR SEC 12 13 N L R G B 4 2 1 6 11 10 3 5 7 8 9 N F 19 14 13 12 17 21 11 12 18 22 M1 M2 M3 OP C P COM FAP FCH COM DS B...

Страница 11: ...M 12 DCM DFM 16 10V 13 ACM 14 AVI 15 ACI 17 AFM 14 M01 15 M02 24V 9 S1 9 S2 15 DCM SG SG SGND 13 MCM 4 4 EN 05 CONNECTIONS SQUEME OTHER CONNECTIONS MAGNETIC LOOP DETECTOR RESISTOR AND PUSH BUTTON RESI...

Страница 12: ...SG SGND 13 MCM ON 1 2 ANT STR SEC 12 13 N L R G B 4 2 1 6 11 10 3 5 7 8 9 N F M1 M2 M3 OP C P COM GND FAP FCH COM DS BL GND 24V BR2 R G B 12V E1 BR1 E1 N N L L NO COM 4 15 EN 05 CONNECTIONS SQUEME CLO...

Страница 13: ...4 STR SEC 12 13 N L R G B M1 M2 M3 OP C P COM GND FAP FCH COM DS BL GND 24V BR2 N L N L E1 BR1 E1 N N L L IN 230V OUT 230V A1 A2 NC COM EN UPS UNIT POWER SUPPLY UPS POWER SUPPLY INPUT UPS POWER SUPPLY...

Страница 14: ...5 M02 24V 9 S1 9 S2 15 DCM SG SG SGND 13 MCM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 ON 1 2 ANT STR SEC 12 13 N L R G B 10 8 9 M1 M2 M3 OP C P COM FAP FCH COM DS BL GND 24V BR2...

Страница 15: ...C DC 12 24V LED COM NO AC DC 12 24V EN 05 CONNECTIONS SQUEME EXTERNAL COMPONENTS CONNECTIONS CONTROL BOARD CONNECTIONS CRANK SENSOR RADAR 1 RADAR 2 ELECTRIC BRAKE LIMIT SWITCH OPENING CLOSING LINE 1 L...

Страница 16: ...erent display modes 7 STOP RESET Restarts the device after a failure occurs 8 ENTER Used to enter change programming parameters 3 and 4 cannot be used Only the menus on page 16A can be set by the user...

Страница 17: ...1 Enter at parameter 00 07 and set password You will temporarily unlock the keyboard 2 Change the parameter you want The release will remain until the motor make a new operation WRONG PASSWORD 1 You h...

Страница 18: ...ex 10 1 sec 15 Parameter Function Settings Factory Setting 04 57 PEDESTRIAN OPENING TIME This menu can select the length of the pedestrian opening Knowing that 100 means 8M if put 12 means opening of...

Страница 19: ...ton or a previously programmed remote control when you want the opening slowdown to start the speed automatically reduces Press the OP button or a previously programmed remote control when you want th...

Страница 20: ...ation time too short Increase the acceleration time OVERCURRENT DURING DECELERATION 01 Short circuit at the motor output Check that the isolation on the output lines is in good condition DETECTION OF...

Отзывы: