Motorline professional MC112PR Скачать руководство пользователя страница 4

3

EN

01. SAFETY INSTRUCTIONS

to the release mechanism.

• Disconnect means, such as a switch or circuit breaker on the electrical 

panel, must be provided on the product’s fixed power supply leads in 

accordance with the installation rules.

• If the product to be installed requires power supply of 230Vac or 

110Vac, ensure that connection is to an electrical panel with ground 

connection.

•The product is only powered by low voltage satefy with central (only 

at 24V motors)

WARNINGS FOR USERS

• Keep this manual in a safe place to be consulted whenever necessary.

• If the product has contact with fluids without being prepared, it must 

immediately disconnect from the power supply to avoid short circuits, 

and consult a specialized technician.

• Ensure that technician has provided you the product manual and 

informed you how to handle the product in an emergency.

• If the system requires any repair or modification, unlock the automatism, 

turn off the power and do not use it until all safety conditions have 

been met.

• In the event of tripping of circuits breakers of fuse failure, locate 

the malfunction and solve it before resetting the circuit breaker or 

replacing the fuse. If the malfunction is not repairable by consult this 

manual, contact a technician.

• Keep the operation area of the motorized gate free while the gate in in 

motion, and do not create strength to the gate movement.

• Do not perform any operation on mechanical elements or hinges if the 

product is in motion.

RESPONSABILITY

• Supplier disclaims any liability if:

• Product failure or deformation result from improper installation 

use or maintenance!

• Safety norms are not followed in the installation, use and 

maintenance of the product.

• Instructions in this manual are not followed.

• Damaged is caused by unauthorized modifications

• In these cases, the warranty is voided.

MOTORLINE ELECTROCELOS SA.

Travessa do Sobreiro, nº29

4755-474 Rio Côvo (Santa Eugénia)

Barcelos, Portugal

SYMBOLS LEGEND:

• Important safety 

notices

• Useful information

• Programming 

information

• Potentiometer 

information

• Connectors 

information

• Buttons 

information

Содержание MC112PR

Страница 1: ...V3 0 REV 08 2022 MC112PR MC113PR MC114PR EN USER S AND INSTALLER S MANUAL...

Страница 2: ...estriction of the use of certain hazardous substances in electrical and electronic equipment Applicable in countries with recycling systems This marking on the product or literature indicates that the...

Страница 3: ...enced in terms of usage of the product in a safe manner and who understands the risks and dangers involved Children shouldn t play with the product or opening devices to avoid the motorized door or ga...

Страница 4: ...and do not use it until all safety conditions have been met In the event of tripping of circuits breakers of fuse failure locate the malfunction and solve it before resetting the circuit breaker or r...

Страница 5: ...llows easy and intuitive operation of various parameters and menus through a display It also has other functions such as Human Presence possibility to view the count of cycles carried out by the door...

Страница 6: ...g the operation LEDs LED 1 ON Indicates that it is being powered at 230Vac OFF No power LED 2 ON SEC contact closed OFF SEC contact open LED 3 ON STR contact closed OFF STR contact open LED 4 Programm...

Страница 7: ...24V 9 S1 9 S2 15 DCM SG SG SGND 13 MCM 22 RC 7 RA 21 RB R L1 S L2 T L3 U T1 V T2 W T3 B2 2 B1 DC 1 DC 10 MI1 11 MI2 5 MI3 6 MI4 8 MI5 20 MI6 MI7 4 24V 4 24V 12 DCM 12 DCM DFM 16 10V 13 ACM 14 AVI 15 A...

Страница 8: ...ACM Not used AVI Not used ACI Not used AFM Not used M01 Pulse output for MR13 M02 Output for optional interlocking relay or pre flashing light Programmable at parameter 04 61 MI1 Opening button MI2 Cl...

Страница 9: ...CM ON 1 2 ANT STR SEC 12 13 N L R G B 4 2 1 6 11 10 3 5 7 8 9 N F 10 8 9 3 4 5 2 1 7 20 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 M1 M2 M3 OP C P COM FAP FCH COM DS BL GND 24V...

Страница 10: ...13 MCM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 ON 1 2 ANT STR SEC 12 13 N L R G B 4 2 1 6 11 10 3 5 7 8 9 N F 19 14 13 12 17 21 11 12 18 22 M1 M2 M3 OP C P COM FAP FCH COM DS B...

Страница 11: ...M 12 DCM DFM 16 10V 13 ACM 14 AVI 15 ACI 17 AFM 14 M01 15 M02 24V 9 S1 9 S2 15 DCM SG SG SGND 13 MCM 4 4 EN 05 CONNECTIONS SQUEME OTHER CONNECTIONS MAGNETIC LOOP DETECTOR RESISTOR AND PUSH BUTTON RESI...

Страница 12: ...SG SGND 13 MCM ON 1 2 ANT STR SEC 12 13 N L R G B 4 2 1 6 11 10 3 5 7 8 9 N F M1 M2 M3 OP C P COM GND FAP FCH COM DS BL GND 24V BR2 R G B 12V E1 BR1 E1 N N L L NO COM 4 15 EN 05 CONNECTIONS SQUEME CLO...

Страница 13: ...4 STR SEC 12 13 N L R G B M1 M2 M3 OP C P COM GND FAP FCH COM DS BL GND 24V BR2 N L N L E1 BR1 E1 N N L L IN 230V OUT 230V A1 A2 NC COM EN UPS UNIT POWER SUPPLY UPS POWER SUPPLY INPUT UPS POWER SUPPLY...

Страница 14: ...5 M02 24V 9 S1 9 S2 15 DCM SG SG SGND 13 MCM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 ON 1 2 ANT STR SEC 12 13 N L R G B 10 8 9 M1 M2 M3 OP C P COM FAP FCH COM DS BL GND 24V BR2...

Страница 15: ...C DC 12 24V LED COM NO AC DC 12 24V EN 05 CONNECTIONS SQUEME EXTERNAL COMPONENTS CONNECTIONS CONTROL BOARD CONNECTIONS CRANK SENSOR RADAR 1 RADAR 2 ELECTRIC BRAKE LIMIT SWITCH OPENING CLOSING LINE 1 L...

Страница 16: ...erent display modes 7 STOP RESET Restarts the device after a failure occurs 8 ENTER Used to enter change programming parameters 3 and 4 cannot be used Only the menus on page 16A can be set by the user...

Страница 17: ...1 Enter at parameter 00 07 and set password You will temporarily unlock the keyboard 2 Change the parameter you want The release will remain until the motor make a new operation WRONG PASSWORD 1 You h...

Страница 18: ...ex 10 1 sec 15 Parameter Function Settings Factory Setting 04 57 PEDESTRIAN OPENING TIME This menu can select the length of the pedestrian opening Knowing that 100 means 8M if put 12 means opening of...

Страница 19: ...ton or a previously programmed remote control when you want the opening slowdown to start the speed automatically reduces Press the OP button or a previously programmed remote control when you want th...

Страница 20: ...ation time too short Increase the acceleration time OVERCURRENT DURING DECELERATION 01 Short circuit at the motor output Check that the isolation on the output lines is in good condition DETECTION OF...

Отзывы: