7
12V
GND
GND
P1
12V
GND
S1
GND
COM
NO
NC
S2
GND
COM
NO
NC
D1
D0
LED
12V
GND
D1
D0
LED
DR1
DR2
SYS
IN
ERR
PO
WER
LINK
AC
T
JD1
JD2
J12
GND
P2
12V
GND
D1
D0
LED
12V
GND
D1
D0
LED
EF380
MB17
MA115
RS232
USB
+12V
GND
+12V
GND
HA0488
HA0488
EF30
EF380
+12V
GND
EF30
EN
04. CONNECTIONS
CONNECTION SCHEME
Power Supply
Power Supply
Power Supply
2 car
d r
eader
(In)
2 car
d r
eader
(Exit)
Red
Black
Yellow or white
Brown and blue
Green
2 Door
Exit Button
Interface of
alarm and
fire control
1 Door
Exit Button
Red
Red
Black
Black
Yellow or white
Yellow or white
Green
Green
Brown and blue
Brown and blue
Fio
Card
reader (In)
Car
d
reader (Exit)
Connecting the antenna to
the computer is required
for configuration only.
Once configured, it is not
necessary to continue
using the antenna
connected to a computer.
In EF380, in case
of electrical
failure the door
will open.
MA115 ANTENNA WIRE
Nº
Wire color
Description
(standard version)
Description
(LAN version)
1
Red
+12V
+12V
2
Black
0V
0V
3
Brown
RS232_TXD
RS232_TXD
4
Yellow
RS232_RXD
RS232_RXD
5
Blue
RS232_GND
RS232_GND
6
Gray
TRIGGER
TRIGGER
7
White
DATA1
RX+
8
Green
DATA0
RX-
9
Orange
485R+ (Not used)
TX+
10
Violet
485R- (Not used)
TX-
Red
Black
Yellow or white
Brown and blue
Green
Switch or Hub