background image

9A

9B

21

22

25

26

24

23

EN

EN

Pay attention to installation dimensions mentioned on pages 6B, 7 and 8!

01 

• Fixing rear support

04 

• Install operator on the supports

05 

• Test movement

06 

• Connecting operator to control board 

and configuring control devices.

02 

• Fixing front support

03 

• Remove caps and pins from motor

• The 

Rear support

 must be fixed to the 

pillar or wall using dimensions provided 

in the preceding pages.

It can be fixed using screws with 

mechanical bushing or chemical welding 

process, or one of your choice since it 

provides an appropriate support.

• The operator must be placed on both 

supports the same time to avoid leaving 

the operator suspended by only one of the 

supports.

To make the task easier, you should unlock 

the operator in order to be able to stretch/ 

retract arm easily (see page 4B),to get the 

correct position for supports.

• Install the pins removed earlier on each 

place with a small amount of lubricant for 

less friction.

• Move the door manually to see if the door 

opens and closes uniformly and correctly, 

without any irregular friction during its 

entire travel; 

This will ensure that operator is not 

subjected to problems during operation.

• With the operator installed, connect it 

to control board for system configuration 

(see control board user manual).

Must also configure the desired control 

devices (transmitters, wall switch, etc.) 

and other additional components such 

as antenna, warning light, key selector, 

among others.

• The 

Front support

 should be fixed to the 

gate, respecting height dimensions and 

distance to the rear support.

This may be fixed by using screws, welding 

process, or to choose another long as it 

provides a secure proper support.

• Before installing motor, remove caps 

and pins from  motor.

• At the end of the installation, put back 

plastic covers for a better visual finish of 

the operator.

It is important to respect this installation order!

Otherwise, it is not possible to ensure correct installation and operators may not 

work properly!

04. INSTALLATION

04. INSTALLATION

INSTALLATION STEPS

INSTALLATION STEPS

Содержание LINCE Series

Страница 1: ...v11 0 REV 05 2022 EN USER S AND INSTALLER S MANUAL LINCE230V 110V 24V...

Страница 2: ...his product or the National Environment Agency for details on where and how they can take these items for environmentally safe recycling Business users should contact their vendor and check the terms...

Страница 3: ...ms of usage of the product in a safe manner and who understands the risks and dangers involved Children shouldn t play with the product or opening devices to avoid the motorized door or gate from bein...

Страница 4: ...se it until all safety conditions have been met In the event of tripping of circuits breakers of fuse failure locate the malfunction and solve it before resetting the circuit breaker or replacing the...

Страница 5: ...secure the Lower Part to Middle Part 02 Remove Lower Part The operator LINCE is a product developed exclusively for the automatic opening of swing gates Besides being pratical safe and powerful this...

Страница 6: ...cated in the figure to unlock 04 Operator unlocked Note To lock operator so it can work automatically must do it by turning the key anticlockwise Information engraved on the unlock shaft D Unlock B Lo...

Страница 7: ...assured the correct functioning and durability of the operators It is also very important to have a levelled ground terrain LINCE300 LINCE400 LINCE600 Power Supply 230V 230Vac 50 60Hz 230Vac 50 60Hz...

Страница 8: ...a 900 W 1095 a 1100 W 1495 a 1500 INTERIOR OPENING INSTALLATION QUOTAS 04 INSTALLATION On the Illustrated diagrams below and on the next page are the dimensions for the installation of the automated s...

Страница 9: ...99 95 92 360 92 93 95 96 97 99 95 91 380 92 93 94 96 97 95 91 400 92 93 94 95 95 91 W 695 a 700 W 900 a 905 EXTERNAL OPENING INSTALLATION QUOTAS 04 INSTALLATION On the Illustrated diagrams below and...

Страница 10: ...bricant for less friction Move the door manually to see if the door opens and closes uniformly and correctly without any irregular friction during its entire travel This will ensure that operator is n...

Страница 11: ...It is important to use mechanical stoppers in the opening and closing position of the gate If not respected components of the automation may suffer efforts for which they were not prepared and as a re...

Страница 12: ...l board Pull it out and send it to our MOTORLINE technical services for diagnosis 4 If the motors doesn t work remove them from installation site and send to our MOTORLINE technical services for diagn...

Страница 13: ...d to remove the automatism from the place it is installed because in this way it is possible to understand if the automatism can function properly connected directly to the current You should use a ne...

Страница 14: ...a homogeneous layer of lubricant over the arm Remove front and rear caps Place a small amount of lubricant on the holes that contains support pins Install caps on the respective holders Make sure that...

Отзывы: