Motorline professional LINCE 400 Скачать руководство пользователя страница 6

On the Illustrated diagrams below and on the next page, are the horizontal dimensions 

for the installation of the  automated system.

04

INSTALATION

▷ HORIZONTAL INSTALATION DIMENSIONS

It is very important that these dimensions are respected! 

Only this way can be 

assured the correct functioning and durability of the operators!

HORIZONTAL INSTALATION DIMENSIONS ◁

04

INSTALATION

05.A

05.B

▷ LINCE400

▷ LINCE600

X

Y

W

Opening 

angle

INTERIOR OPENING 

120 to 180

160 to 180

120 to 350

200 to 280

120 to 180
120 to 140

120 to 200
120 to 200

1095 to 1100
1095 to 1100

1495 to 1500
1495 to 1500

95°

120°

95°

120°

▷ LINCE400

▷ LINCE600

X

Y

W

Opening 

angle

160 to 200

160 to 300

120 to 180

120 to 280

695 to 700

900 to 905

95°

95°

EXTERIOR OPENING

(EXTERIOR)

(INTERIOR)

(EXTERIOR)

(INTERIOR)

Distance between the 

centers of the holes on the 

supports from operator

Axis of rotation of the gate

(center of the door hinge)

Axis of rotation of the gate

(center of the door hinge)

Axis of rotation of the 

motor, on the rear support

Axis of rotation of the 

motor, on the front 

bracket

 Opening 

direction

X

Y

W

Closing mechanical 

stopper

Opening mechanical stopper

Distance between the centers of the 

holes on the supports from operator

LEGEND:

Dimension X - Horizontal distance 

between hinge axis of the door and the rear axle of the motor.

Dimension Y - Vertical distance 

between hinge axis of the door and the rear axle of the motor.

Dimension W - 

Distance between axis of the motor brackets

Axis of rotation of the 

motor, on the rear support

Axis of rotation of the motor, 

on the front support

 Opening 

direction

X

Y

W

Closing mechanical stopper

Opening mechanical stopper

B

Содержание LINCE 400

Страница 1: ...LINCE 400 600 User s and Intaller s manual v1 0 REV 09 2013...

Страница 2: ...manual Any other use not expressly indicated here could compromise the good condition operation of the product and or be a source of danger ELECTROCELOS SA is not responsible for the improper use of...

Страница 3: ...opening of swing gates Besides being pratical safe and powerful this product has a new function incorpo rated so that you can transform a motor to apply on right leaves to left leaves This allows grea...

Страница 4: ...ll components with the screws 07 Full transformed operator 01 Remove the plastic cap from the rear end Information engraved on the unlock shaft D Unlock B Lock 02 Insert Release key on the unlock shaf...

Страница 5: ...lower than the height of the rear support See example below 03 OPERATOR TECHNICAL SPECIFICATIONS It is very important that these dimensions are respected Only this way can be assured the correct func...

Страница 6: ...R OPENING EXTERIOR INTERIOR EXTERIOR INTERIOR Distance between the centers of the holes on the supports from operator Axis of rotation of the gate center of the door hinge Axis of rotation of the gate...

Страница 7: ...e to stretch retract arm easily see page 03 B to get the correct position for supports 04 Install operator on the supports 05 Test movement Install the pins removed earlier on each place with a small...

Страница 8: ...as a result will be damaged It is important to use junction boxes for connections between motors components and control unit All cables must enter and exit on the bottom of the junction and control b...

Страница 9: ...faulty 3 If the motors doesn t work remove them from installation site and send to our MOTORLINE technical services for diagnosis 4 If motors work well and move gate at full force during the entire c...