Remove the front cover of the safe profile to access the interior:
A ⋅
Loosen the cover screws;
B ⋅
Open the cover and remove it.
Position the safe profile in the installation location, and make the necessary markings to perform
one of the 4 possible types of fixation.
In the case of installation
in BRISA SOLAR, the safe
profile has markings for
holes at the top so that when
aligning the safe profile with
BRISA SOLAR, you can drill
holes without damaging the
drainage system.
There are 3
signal holes
on the lateral
plates of the
safe profile
that indicate the
areas for lateral fixing.
The holes chosen for fixing
must be enlarged to insert
the screws.
TOP FIXATION
LATERAL FIXATION
FRONTAL FIXATION
BRISA SOLAR FIXATION
Remove the tarpaulin roll with motor:
• Unhook the motor from its support, pulling the tube to the opposite side;
• Pull the motor side out of the safe profile;
• Move to the side, so that it detaches from the support on the opposite side.
Drill holes and secure the safe profile with washers and screws.
REMOVE THE MOTOR
SAFE PROFILE FIXATION