EN
35
MESSAGES MEANING
--
Gate closed or switch-on after shutdown
OP
Gate opening
CL
Gate closing
SO
Gate stopped during opening
SC
Gate stopped during closure
F1
Photocell 1 tripped
F2
Photocell 2 tripped
HA
Gate stopped by external event
ALI
Re-alignment procedure
oP
Gate stopped without automatic reclosure
OPd
Gate in partial opening mode
Pe
Gate in partial opening position without automatic reclosure
-tC
Gate open with timed reclosure - Flashing dash counting in progress
Dash replaced by figures 0..9 countdown (last 10s)
-tP
Gate in partial opening position with timed reclosure - Flashing dash counting in progress
Dash replaced by figures 0..9 countdown (last 10s)
L--
Learning stopped due to activation of safety device or motor inversion
LOP
Learning on M1 opening
LO
.
P
.
Learning on M2 opening
LCL
Learning on M1 closing
LC
.
L
.
Learning on M2 closing
SOP
Point of M1 deceleration on opening (only during stroke learning)
SO
.
P
.
Point of M2 deceleration on opening (only during stroke learning)
SCL
Point of M1 deceleration on closing (only during stroke learning)
SC
.
L
.
Point of M2 deceleration on closing (only during stroke learning)
In “NORMAL OPERATING MODE”, i.e. when the system is powered up normally, the 3-figure LCD display shows the following status messages:
4.6 - Display during normal operation
EVENT
DESCRIPTION
FLASHING INDICATION AND
CONTROL UNIT LED
opening
Gate opening
closure
Gate closing
automatic closure
Gate open with timed reclosure active
stop during closure Gate stopped during closure
stop during opening Gate stopped during opening
open
Gate completely open without automatic reclosure
closed
Gate completely closed
programmation
During the programming phase
2 quick f pause + 1 flash
obstacle M1/M2
Motor 1/2 obstacle detected
4 quick f pause, 3 times
photo 1!
Photocell 1 tripped
2 quick f pause, 3 times
photo 2!
Photocell 2 tripped
2 quick f pause, 3 times
sensitive edge!
Sensitive edge tripped
5 quick f pause, 3 times
partial opening
Partial opening in progress
automatic partial
closure
Gate opening to partial position with timed reclosure activated
realignment
Realignment after a manual release
phototest error
Phototest error detected
3 quick f pause, 3 times
IND/ELEC error
Electric lock / gate open light line overload
6 quick f pause, 3 times
SURGE OVERLOAD ALARM
The motor’s current drawdown has increased very quickly
EOL
1. The gate has hit an obstacle (M1)
2. There is friction on the leaf of M1
EO
.
L
.
1. The gate has hit an obstacle (M2)
2. There is friction on the leaf of M2
SAFETY EDGE ALARM
The control unit has received a signal from the safety edge
EED
1. The safety edge has been pressed.
2. The safety edge is not connected correctly
PHOTOCELL ALARM/SAFETY EDGE
Phototest fail outcome
EPH
1. Check the photocell and the safety edge connections
2. Check that the photocells and the safety edg are operating correctly
Malfunctions
This section lists a number of malfunctions which may occur.