DMR 50-5/50 Installation Guide V3.0 Pag. 20
6
Connection schematic
Warning:
Before commissioning, it is essential that the safety instructions in the relevant section
are read and understood, and then observed!
Non-observance can result in danger to persons or damage to the equipment.
Disconnect the electrical power supply before any operation on the device.
CAUTION:
Incorrect connection of motor power electronics.
The motor is not equipped with reverse polarity protection.
Consequence:
Destroying of the power electronics possible.
Check the right polarity
.
NOTICE:
Loops must be avoided for all grounding concepts. Shielded cable must be used for the
whole cable system without interruption. Up to a length of 10m a common power and
signal cable can be used. If the cable is longer than 10m it is recommended to separate
power and signal in different shielded cables. When standard wires from Motor Power
Company are used, the shielding must be spaciously applied inside the control cabinet.
Failure to follow them can result in danger to persons or damage to the equipment.