background image

                                                                                

 

© Motor City Wash Works, Inc. 48285 Frank, Wixom Michigan 48393 U.S.A. 

Phone: 248.313.0272 

 Fax: 248. 313.0271 

        

REVISION 1.0 09-24-09

                             

www.motorcitywashworks.com

                                                 

5

 

 

 

   Warranty and Return Procedure: 

                 

 

 

 
 
Motor City Wash Works

 warrants this product to be free of defect in material and/or workmanship for a period of 

one year

 from the date purchase. During the warranty period MCWW will at its discretion, at no charge to the 

customer, repair or replace this product if found defective, with a new or refurbished unit, not to include costs of 
removal or installation. Any product returned to MCWW for warranty has to have a 

Return Material Authorization 

Number

. All shipping costs to MCWW are assumed by the customer. This is only a summary of 

MCWW’s Limited 

Warranty

. Please, communicate with MCWW for our complete warranty. 

Prior

 to returning any product to MCWW, the customer must call in for a 

Return Material Authorization Number

 

and a copy of our 

Return Material Authorization 

Form must be completed. The 

RMA

 number must be written 

clearly on the outside of the shipping package and copy of the form must be included in the package.  

Содержание Wanner HPPREPSYSTEM004

Страница 1: ...This pump is capable of delivering fresh water as well as filtered reclaim water Typically used as a prep station this unit uses one Wanner D10 Hydra Cell Pumps and is belt driven by a 7 1 2HP electrical motor Suggested Installation Tools and Materials 5 Hammer Drill with 3 8 Drill Bit 8 Wedge Anchor Bolts 3 8 x 4 Sledge Hammer Safety Goggles Set of Standard Combo Wrenches Torpedo Level Measuring ...

Страница 2: ...ed for your protection Review thoroughly with all personnel WARNING NEVER ATTEMPT TO WORK ON THE EQUIPMENT WHILE IT IS RUNNING PERSONNEL MUST BE TRAINED IN SAFE OPERATING PROCEDURES ALL PERSONNEL SHOULD REVIEW THIS MANUAL PERIODICALLY EMERGENCY STOP BUTTONS MUST BE WELL MARKED AND THEIR LOCATION AND OPERATION REVIEWED WITH ALL PERSONNEL MAINTENANCE OR REPAIR WORK ON EQUIPMENT MUST BE PERFORMED ONL...

Страница 3: ...xceed 140o F B Before starting the Pump make sure that all connections are tight and that the discharge system is open C Check for oil in pump Level should be 1 from top D Turn the unit on keeping hands and loose clothing away from unit at all times Allow unit to run for at least 2 minutes E Turn adjusting bolt CW to desired pressure by reading gauge Refer to page 1 for your unit operating pressur...

Страница 4: ...HARMFUL IN THE EVENT OF OVERSPRAY ONTO SOMEONE 8 If pump is located where temperature might drop below 45 F use S A E 5W30 oil in pump Maintenance Schedule Trouble Shooting Chart Trouble Possible Cause Probable Remedy Excess pressure required to bypass fluid Regulator not properly adjusted Check pressure and set regulator accordingly Not enough fluid being bypassed Ensure reservoir is being suppli...

Страница 5: ... defective with a new or refurbished unit not to include costs of removal or installation Any product returned to MCWW for warranty has to have a Return Material Authorization Number All shipping costs to MCWW are assumed by the customer This is only a summary of MCWW s Limited Warranty Please communicate with MCWW for our complete warranty Prior to returning any product to MCWW the customer must ...

Отзывы: