12
headline bars
con
tinua
tion tabs
not
es
w
ar
nings
headline bars
continuation tabs
notes
warnings
model no. 011-1978-2 | contact us 1-888-942-6686
OPERA
TION
ABORTED CHARGE
If charging cannot be completed normally,
charging will abort. When charging aborts, the
charger’s output is shut off and the Red LED will
blink. The digital display will show an error code
(see Troubleshooting for a description of the error
codes). To reset after an aborted charge, unplug
the charger from the AC outlet, wait a few minutes
and then plug it back in.
DESULFATION MODE
If the battery is left discharged for an extended
period of time, it could become sulfated and not
accept a normal charge. If the charger detects
a sulfated battery, the charger will switch to a
special mode of operation designed for such
batteries, and the display will show
SUL
. If
successful, normal charging will resume after the
battery is desulfated. Desulfation could take up to
10 hours. After 10 minutes in desulfation, the red
LED will blink. After 10 hours, if desulfation fails,
charging will abort, the display will show
F02
, and
the red LED will remain blinking.
COMPLETION OF CHARGE
Charge completion is indicated by the Charged/
Maintaining (green) LED. When lit, the charger has
switched to the maintain mode of operation.
MAINTAIN MODE
(FLOAT MODE MONITORING)
When the Charged/Maintaining (green) LED is lit,
the charger has started maintain mode. In this
mode, the charger keeps the battery fully charged
by delivering a charge current when necessary. If
the charger has to provide an excessive maintain
current for a continuous 12-hour period, it will
go into abort mode (see Aborted Charge section).
This is usually caused by a drain on the battery or
the battery could be bad.
MAINTAINING A BATTERY
This product charges and maintains both 6 V and
12 V batteries. The maintain mode technology
allows you to safely charge and maintain a healthy
battery for extended periods of time. However,
problems with the battery, electrical problems
in the vehicle, improper connections or other
unanticipated conditions could cause excessive
current draws. As such, occasionally monitoring
your battery and the charging process is required.
USING THE BATTERY VOLTAGE TESTER
1.
With the charger unplugged from the AC
outlet, connect the charger to the battery,
following the instructions given in previous
sections.
2.
Plug the charger AC power cord into the AC
outlet.
3.
If necessary, press the Battery Type button
until the correct type is indicated.
4.
Read the voltage on the digital display. Keep
in mind that this reading is only a battery
voltage reading; a false surface charge may
mislead you. Compare the reading to the
following chart.
6 V BATTERY
VOLTAGE
READING
12 V BATTERY
VOLTAGE
READING
BATTERY
CONDITION
6.4 or more
12.8 or more
Charged
6.1 to 6.3
12.2 to 12.7
Needs charging
Less than 6.1
Less than 12.2
Discharged
headline bars
continuation tabs
notes
warnings
NOTE:
The battery tester is only designed to test batteries. Testing a device with a rapidly changing