background image

CAUTION!

Only use the cables provided with your power inverter.

• Screw off the caps of the DC cabling terminals (B / C).
• Connect the cable with the DC cabling terminals (B / C).

CAUTION!

Make sure to connect the 

RED CABLE TO POSITIVE PORT

 (+) and the 

BLACK CABLE TO

NEGATIVE PORT

 (-).

• Place the red cable connector on the positive DC cabling terminal (+ / red). Make sure that 

the respective holes are matching. Screw the red cap back on the cabling terminal until the 

• 

• Place the black cable connector on the negative DC cabling terminal (- / black). Make sure 

that the respective holes are matching. Screw the black cap back on the cabling terminal 

PO) RED
CABLE CONNECTOR

Connecting the power converter.

CAUTION!

Prior to connecting to the power source:
Make sure that the total wattage of the devices you are planning to connect to the mobile 
power outlet does not exceed the maximum load of the respective power outlet.

LOAD CONNECTED (W)

CONNECTION WITH
12 V OUTLET PLUG

CONNECTION WITH
VEHICLE BATTERY

Continuous load under 100 W Yes

Yes

Continuous load between
100 and 400 W

No

Yes

Connecting the connector cables to the power inverter.

< 100 W

< 400 W

• Make sure that the power inverter is switched off by verifying that the on/off switch (H) is 

set on the "O" position.

• Choose the DC cable (I / H) suitable for connecting the AC products that you want to operate.

16

model no. 011-2038-4  |  contact us:  1-877-466-8191

17

OPERATION

OPERATION

Содержание 011-2038-4

Страница 1: ...WER INVERTER SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions Read all instructions and follow them with use of this product Questions Call Customer Service Hotline 1 877 466 8191 model no 011 2038 4 ...

Страница 2: ...ight 2 lb 6 1 2 oz 1 2 kg TECHNICAL SPECIFICATIONS SAFETY INFORMATION KEY PARTS DIAGRAM INTENDED USE Options for connecting devices to the power inverter OPERATION Determining the maximum load of connected device Wattage of commonly used devices Before you start Connecting the Power Inverter Connecting the connector cables to the power inverter Connecting the power inverter to a lighter socket loa...

Страница 3: ...ry WARNING HEATED SURFACE The power inverter housing may become uncomfortably warm and can reach up to 60 C 140 F under extended high power operation Do not use the power inverter in a truck in which the plus pole of the car battery is connected to the chassisl Before using the device please determine how the battery is connected in the respective vehicle Do not operate the power inverter if it ha...

Страница 4: ...V or 24 V battery to the power inverter must be positive to positive and negative to negative A reverse polarity connection positive to negative will blow a fuse in the power inverter and might need to replace a new fuse Damage caused by a reverse polarity connection is not covered by your warranty Disconnect the power cable whenever the engine is switched off for extended periods of time In some ...

Страница 5: ...al B Positive DC cabling terminal C DC cable with battery clamps DC CABLE WITH Two USB ports D AC Outlet E ON OFF Switch G Power Indicator Light F 12 V OUTLET PLUG H 8 model no 011 2038 4 contact us 1 877 466 8191 9 KEY PARTS DIAGRAM KEY PARTS DIAGRAM ...

Страница 6: ...xample 120 Volts x 2 Amperes 240 Watts CAUTION Understand the difference between rated running wattage and surge starting wattage The RATED RUNNING WATTAGE is the average amount of power that a device consumes continuously DO NOT overload your power inverter Overloading the power inverter even for a short time could result in serious damage to the power inverter and or to the connected device A fe...

Страница 7: ...upply momentary surge power that is higher 800 W than its maximum power rating 400 W Some products with a rated wattage lower than the maximum power rating for your power inverter may still exceed the power inverter s surge capability and trigger an overload shutdown Products rated with the following power and surge ratings or less can be connected to the power inverter NOTE Power requirements for...

Страница 8: ...carton should contain Power inverter DC cable with 12 V outlet plug H DC cable with battery clamps I Owner s manual Check the power inverter s identification label to ensure that you have purchased the intended model and that it has the required specifications for its intended use Positioning of the power inverter Position the power inverter on a flat and stable surface in a location that is Do no...

Страница 9: ...cabling terminal POSITIVE RED CABLE CONNECTOR Connecting the power converter CAUTION Prior to connecting to the power source Make sure that the total wattage of the devices you are planning to connect to the mobile power outlet does not exceed the maximum load of the respective power outlet LOAD CONNECTED W CONNECTION WITH 12 V OUTLET PLUG CONNECTION WITH VEHICLE BATTERY Continuous load under 100 ...

Страница 10: ... outlet when starting the engine Connecting the power inverter to a battery from 12 V Vehicles and 24 V Trucks Boats RVs Safety guidelines for handling batteries DANGER A spark may be visible when making the connection to a battery because a current will flow to charge the capacitors In the power inverter Do not make this connection In the presence of flammable fumes Explosion or fire may result T...

Страница 11: ...during operation Follow the instructions in the section See connecting the connector cables to the power inverter to connect the DC cable to the power inverter If the battery can be switched off switch it off The power inverter is now ready for use CAUTION If you are going to disconnect the battery switch the power inverter off first See Switching on off CAUTION Always disconnect the power cables ...

Страница 12: ... in the connected device the green indicator turns to red indicator Please restart the unit manually Built in fan activated when a significant amount of power increase the internal temperature and it exceeds its ambient operating temperature Replaceable 8 A fuse use for continued protection against a risk of fire or electric shock and should be replaced manually if necessary Plug in the devices th...

Страница 13: ...FUSE REPLACEMENT WARNING cable H Remove the faulty fuse Insert a new fuse and screw the cover of the plug back on For continued protection against risk of fire or electric shock replace only with a fuse of the same type and rating 125 V 8 A Follow the instructions to replace the fuse inside the 12 V outlet plug of your connector While the engine is running the power inverter can be connected to th...

Страница 14: ...f you connect a device that is rated too high or a load that draws excessive surge power the power inverter shuts down Use a product with a power rating within the power inverter s continuous power rating See operation PROBLEM POSSIBLE CAUSE SOLUTION ERROR SIGNAL Low battery alarm and low voltage shutdown As the battery discharges its voltage decreases Voltage drops to 21 0 22 0 20 0 22 0 V V Shut...

Страница 15: ... brush to clear any blocked ventilation holes Move the power inverter to a cooler place Reduce the load if continuous operation is required ALARM POSSIBLE CAUSE SOLUTION ERROR SIGNAL Overheat shutdown Power indicator light F turns on PROBLEM POSSIBLE CAUSE SOLUTION The connected device does not switch on The battery is defective Check the battery and replace it if required The power inverter is da...

Страница 16: ...own fuse Replace fuse Television interference TV signals are weak Adjust the orientation of the power inverter television antenna and cables Maximize TV signal strength by using a better antenna and use shielded antenna cable where possible Try a different TV model This MotoMaster product carries a one 1 year warranty against defects in workmanship and materials At its discretion MotoMaster Canada...

Отзывы: