PROBLEM

POSSIBLE CAUSE

SOLUTION

ERROR SIGNAL

Low battery 

alarm and 

low-voltage 

shutdown

As the battery discharges, its 

voltage decreases. Voltage 

drops to  21.0–22.0

 20.0–22.0 V

Shut down sensitive loads 

such as computers and then 

recharge the battery.

Audible alarm

Voltage drops to

20.0–21.0 V

This protects the battery 

from being over-discharged.

Recharge the battery.

Power indicator 

(Green-Red)

(Green-Red)

(Green-Red)

light (F) turns on

High- Voltage 

shutdown

Disconnect the connected 

devices.

Verify that the charging system 

is properly regulated and the 

battery is 24 V nominal.

Power indicator 

light (F) turns on

Overload 

shutdown

Red indicator 

light (F) turns on

The power inverter is equipped with protective shutdown features and an acoustic 
signal. The details are listed in the following table:
Work with 24 V battery, such as Trucks, Boats, RVs

A defective battery charging 
system can cause the battery 
voltage to rise to high levels 
(30.0-32.6 V).
Although the power inverter 
has a protection against high 
voltage, H might still be 
damaged if the input voltage 
were to exceed 32 V.

If you connect a device that 
is rated too high or a load 
that draws excessive surge 
power, the power inverter 
shuts down.

Use a product with a power 
rating within the power 
inverter’s continuous power
rating (See operation). 

PROBLEM

POSSIBLE CAUSE

SOLUTION

ERROR SIGNAL

Low battery 

alarm and 

low-voltage 

shutdown

As the battery discharges, its 

voltage decreases. Voltage 

drops to  21.0–22.0

 20.0–22.0 V

Shut down sensitive loads 

such as computers and then 

recharge the battery.

Audible alarm

Voltage drops to

20.0–21.0 V

This protects the battery 

from being over-discharged.

Recharge the battery.

Power indicator 

(Green-Red)

light (F) turns on

ALARM

POSSIBLE CAUSE

SOLUTION

ERROR SIGNAL

Overheat 

shutdown

The power inverter

shuts down automatically if 

it exceeds its safe operating 

temperature.

Power indicator 

light (F) turns on

Work with 12 V battery, such as Trucks, Boats, RVs

(Green-Red)

• Switch the power inverter 

off and disconnect it from 
the vehicle's 12 V outlet.

• Disconnect all connected 

devices and allow the 
power inverter to cool for 
at least 15 minutes.

• Use a brush to clear any 

blocked ventilation holes. 

• Move the power inverter to 

a cooler place. Reduce the 
load if continuous 
operation is required.

26

model no. 011-2038-4  |  contact us:  1-877-466-8191

27

TROUBLESHOOTING

TROUBLESHOOTING

Содержание 011-2038-4

Страница 1: ...WER INVERTER SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions Read all instructions and follow them with use of this product Questions Call Customer Service Hotline 1 877 466 8191 model no 011 2038 4 ...

Страница 2: ...ight 2 lb 6 1 2 oz 1 2 kg TECHNICAL SPECIFICATIONS SAFETY INFORMATION KEY PARTS DIAGRAM INTENDED USE Options for connecting devices to the power inverter OPERATION Determining the maximum load of connected device Wattage of commonly used devices Before you start Connecting the Power Inverter Connecting the connector cables to the power inverter Connecting the power inverter to a lighter socket loa...

Страница 3: ...ry WARNING HEATED SURFACE The power inverter housing may become uncomfortably warm and can reach up to 60 C 140 F under extended high power operation Do not use the power inverter in a truck in which the plus pole of the car battery is connected to the chassisl Before using the device please determine how the battery is connected in the respective vehicle Do not operate the power inverter if it ha...

Страница 4: ...V or 24 V battery to the power inverter must be positive to positive and negative to negative A reverse polarity connection positive to negative will blow a fuse in the power inverter and might need to replace a new fuse Damage caused by a reverse polarity connection is not covered by your warranty Disconnect the power cable whenever the engine is switched off for extended periods of time In some ...

Страница 5: ...al B Positive DC cabling terminal C DC cable with battery clamps DC CABLE WITH Two USB ports D AC Outlet E ON OFF Switch G Power Indicator Light F 12 V OUTLET PLUG H 8 model no 011 2038 4 contact us 1 877 466 8191 9 KEY PARTS DIAGRAM KEY PARTS DIAGRAM ...

Страница 6: ...xample 120 Volts x 2 Amperes 240 Watts CAUTION Understand the difference between rated running wattage and surge starting wattage The RATED RUNNING WATTAGE is the average amount of power that a device consumes continuously DO NOT overload your power inverter Overloading the power inverter even for a short time could result in serious damage to the power inverter and or to the connected device A fe...

Страница 7: ...upply momentary surge power that is higher 800 W than its maximum power rating 400 W Some products with a rated wattage lower than the maximum power rating for your power inverter may still exceed the power inverter s surge capability and trigger an overload shutdown Products rated with the following power and surge ratings or less can be connected to the power inverter NOTE Power requirements for...

Страница 8: ...carton should contain Power inverter DC cable with 12 V outlet plug H DC cable with battery clamps I Owner s manual Check the power inverter s identification label to ensure that you have purchased the intended model and that it has the required specifications for its intended use Positioning of the power inverter Position the power inverter on a flat and stable surface in a location that is Do no...

Страница 9: ...cabling terminal POSITIVE RED CABLE CONNECTOR Connecting the power converter CAUTION Prior to connecting to the power source Make sure that the total wattage of the devices you are planning to connect to the mobile power outlet does not exceed the maximum load of the respective power outlet LOAD CONNECTED W CONNECTION WITH 12 V OUTLET PLUG CONNECTION WITH VEHICLE BATTERY Continuous load under 100 ...

Страница 10: ... outlet when starting the engine Connecting the power inverter to a battery from 12 V Vehicles and 24 V Trucks Boats RVs Safety guidelines for handling batteries DANGER A spark may be visible when making the connection to a battery because a current will flow to charge the capacitors In the power inverter Do not make this connection In the presence of flammable fumes Explosion or fire may result T...

Страница 11: ...during operation Follow the instructions in the section See connecting the connector cables to the power inverter to connect the DC cable to the power inverter If the battery can be switched off switch it off The power inverter is now ready for use CAUTION If you are going to disconnect the battery switch the power inverter off first See Switching on off CAUTION Always disconnect the power cables ...

Страница 12: ... in the connected device the green indicator turns to red indicator Please restart the unit manually Built in fan activated when a significant amount of power increase the internal temperature and it exceeds its ambient operating temperature Replaceable 8 A fuse use for continued protection against a risk of fire or electric shock and should be replaced manually if necessary Plug in the devices th...

Страница 13: ...FUSE REPLACEMENT WARNING cable H Remove the faulty fuse Insert a new fuse and screw the cover of the plug back on For continued protection against risk of fire or electric shock replace only with a fuse of the same type and rating 125 V 8 A Follow the instructions to replace the fuse inside the 12 V outlet plug of your connector While the engine is running the power inverter can be connected to th...

Страница 14: ...f you connect a device that is rated too high or a load that draws excessive surge power the power inverter shuts down Use a product with a power rating within the power inverter s continuous power rating See operation PROBLEM POSSIBLE CAUSE SOLUTION ERROR SIGNAL Low battery alarm and low voltage shutdown As the battery discharges its voltage decreases Voltage drops to 21 0 22 0 20 0 22 0 V V Shut...

Страница 15: ... brush to clear any blocked ventilation holes Move the power inverter to a cooler place Reduce the load if continuous operation is required ALARM POSSIBLE CAUSE SOLUTION ERROR SIGNAL Overheat shutdown Power indicator light F turns on PROBLEM POSSIBLE CAUSE SOLUTION The connected device does not switch on The battery is defective Check the battery and replace it if required The power inverter is da...

Страница 16: ...own fuse Replace fuse Television interference TV signals are weak Adjust the orientation of the power inverter television antenna and cables Maximize TV signal strength by using a better antenna and use shielded antenna cable where possible Try a different TV model This MotoMaster product carries a one 1 year warranty against defects in workmanship and materials At its discretion MotoMaster Canada...