4.2 Manipulator Cable Connection
4-3
HW0484074
HW0484074
4.2.1
Connection to the Manipulator
Before connecting the manipulator cables to the manipulator, verify the connector numbers:
both the cables and the connectors on the manipulator base are marked with 1BC, 2BC, and
3BC. Connect the cables in the order of 3BC, 2BC, 1BC, referring to " Fig. 7 (a) Manipulator
Cable Connection (To the Manipulator) ". When connecting, insert each cable connector
adjusting its position to the main keys on the connector base of the manipulator, and set the
lever low until it clicks.
4.2.2
Connection to the NX100
Before connecting the manipulator cables to the NX100, verify the connector numbers: both
the cables and the connectors on the NX100 are marked with X11, X21, and X22. Connect the
cables in the order of X22, X21, X11, referring to " Fig. 7 (b) Manipulator Cable Connection
(To the NX100) ". When connecting, insert each cable connector adjusting its position to the
main keys on the NX100, and then set the lever low until it clicks.
Fig. 6 Manipulator Cables
X22
3BC
X22
3BC
NX100
Manipulator
Manipulator
NX100
Encoder Cable
2BC
Power Cable
3BC
Power Cable
1BC
X21
2BC
X21
2BC
NX100
Manipulator
X11
1BC
X11
1BC
23/59