4.11.2 Motor installation on parallel style models with RediMount system
1. Make sure the extension tube is fully retracted
and then remove the sealing plug.
2. Press the motor shaft on to the coupling inside
of the belt gear flange.
3. Use a hexagon key to tighten the coupling
around the motor shaft. Correct tightening
torque for PC25 models = 0.85 Nm and for
PC32 and PC40 = 2.0 Nm.
4. Bolt the motor to the flange using four screws.
Tighten the screws according to table T6.3.1.
5. Put the sealing plug back.
4.11.3 Removal of motor from a unit with RediMount system
If removing a motor from a unit with RediMount system the extension tube must be fully extended to
make it possible to losen the coupling.