background image

 

12

Photo adapter SY10

 

  Attaches to the top of the trinocular tube, allowing any SLR camera to be connected to the  

 

microscope for imaging purposes. 

  The SY10 adapter for the selected camera has to be screwed into the adapter before connecting to  

 

the camera. This SY10 adapter can be obtained from any camera store in your area. 

  Can only be used with the SMZ-161T. 

 

C-mount or CS-mount 

  Attaches to the top of the trinocular tube, allowing any CCD camera or imaging device to be  

 

connected to the microscope.  

 

Select either the C-mount or CS-mount according to the CCD camera to be used. 

  Can only be used with the SMZ-161T. 

 

Improved industrial boom stands 

  With new slot / groove design for better locking of microscope. 

  Grub screw locks into slot / groove, stopping tilt. Microscope is positioned vertical to base with no  

 slant 

  Add position for hand-carrying around four sides 

  Newly design stands can be used in wide-range of our SMZ series microscopes which allows  

 

observing larger viewing samples 

  Only one H3 Allen key is necessary for adjusting the boom stand. 

  Aluminum support collar with elastic plastic gasket to protect and avoid scratches on the column. 

 

Содержание 1100201300082

Страница 1: ...SMZ 161 Series Stereo Zoom Microscopes Instruction Manual...

Страница 2: ...rements of modern research techniques and testing methods This involves modification to the mechanical structure and optical design of our instruments Therefore all descriptions and illustrations in t...

Страница 3: ...ng Distance 6 3 4 Changing the Bulb 7 4 KNOWING YOUR MICROSCOPE 8 4 1 Stereo Body with Binocular or Trinocular Head 8 4 2 Stand 9 4 3 External Illuminator 9 4 4 Eyepieces and Auxiliary Objectives 10 4...

Страница 4: ...remains perfectly parfocal The SMZ 161 is the ideal instrument for examining objects of industrial biological medical or educational nature SMZ 161 Standard Configuration and Parameters For detailed s...

Страница 5: ...4 1 1 Nomenclature SMZ 161 R2GG R2LED Fig 1 SMZ 161 TP Fig 2...

Страница 6: ...ertical post This is important as this collar keeps the microscope from sliding down the column 2 2 3 The head holder should rest on the support collar and both the head holder locking screw and the c...

Страница 7: ...e focusing knob focus the sample using the highest magnification strength If the sample cannot be brought into focus adjust the height of the microscope along the column Remember to tighten the lockin...

Страница 8: ...dule Screw the collector piece back in after changing the old one 3 4 3 For transmitted light turn the microscope over so that the bottom plate of the stand faces towards the user Remove the bottom pl...

Страница 9: ...gnification is changed parfocal For adjustment procedures refer to section 3 2 of this manual The stereo body is mounted onto the circular mount of the head holder and is locked into place using the l...

Страница 10: ...the bottom of the stand on the right hand side This knob governs the light intensity for the transmitted and incident lights The illuminating angle of the incident light can be adjusted using the scr...

Страница 11: ...cluding 10X 15X and 20X Standard configuration is a pair of 10X eyepieces 4 4 2 To change the eyepieces unscrew the locking screw remove the original eyepieces replace with the new pair of eyepieces a...

Страница 12: ...echniques in Bio Med applications including In situ silver gain staining and embryo observation Polarizing kit Must be used with transmitted light This kit including both a polarizer and analyzer is a...

Страница 13: ...onnected to the microscope Select either the C mount or CS mount according to the CCD camera to be used Can only be used with the SMZ 161T Improved industrial boom stands With new slot groove design f...

Страница 14: ...added to shield against dust and moisture 5 2 Protection against Water and Moisture The instrument should be kept away from all water sources including pipes and sinks Humidity in the room where the i...

Страница 15: ...nds one hand holding the bottom of the stand and the other hand holding the top of the vertical post of the head holder of the microscope 5 4 4 The microscope should always be kept upright while movin...

Страница 16: ...dapters 0 5X 0 65X 1X adapters available Auxiliary ESD objectives 0 3X WD 301 mm 0 5X WD 191 8 mm 0 63X WD 142 7 mm 0 75X WD 128 6 mm 1 5X WD 56 3 mm 2 0X WD 38 6 mm Max working distance with 0 3X aux...

Страница 17: ...16...

Страница 18: ...Tel 34 93 756 6286 Fax 34 93 756 6287 Website http www motic com E mail info speedfair com Motic China Group Ltd China Motic Building Torch Hi Tech Industrial Development Zone Xiamen P R C Tel 86 0592...

Отзывы: