2.3 Application

The high quality 

MOTIC RED30 Series stereo microscopes feature compact structure, light weight, long working 

distance, superior optical performance and high resolution. They are guaranteed to have accurate alignment and be 
parfocal, making them the perfect tools for teaching activities and scientific and industrial research. 

2.4 Instrument and its technical specifications

Model

RED30S

RED39Z

Total Magnification

20X / 40X

10X-30X

Eyepiece

WF10X

Types of Head

Integrated head and stand

Removable head

Body Tube

45° titling binocular body tube

Travel range
Working distance

47mm

68mm

Built-in Rechargeable  
Battery (N/Y)

Y

Illumination

Incident and Transmitted LED illumination

Optional Objectives

Objectives: 1X, 3X, 4X

All of the models in the 

RED30 Series stereo microscopes are provided with incident and transmitted LED illumina-

tion.. The brightness adjustment knobs on both sides of the base are used to turn on/off the incident and transmit-
ted illumination, as well as regulate the brightness. The main power switch is located at the back of the base. 

The linked sample clip holder is easy to use. Push the central part (marked “PUSH”) of the assembly to automati-
cally raise the sample clips on both sides, place the specimen and then release. The REDLINE series of stereo 
microscopes is also provided with a handle to facilitate handling.

Содержание 1100201000026

Страница 1: ...Motic Incorporation Ltd Instructions Manual English RED30 SERIES...

Страница 2: ......

Страница 3: ...2 2 Part names 08 2 3 Application 09 2 4 Instrument and its technical specifications 09 3 First time use operation 10 3 1 First time use 10 3 2 Operation of the stereo microscopes 12 3 3 Modification...

Страница 4: ......

Страница 5: ...to the EN 61010 1 2001 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use 1 3 Unpacking transportation storage The original shipping container a foam box in a fibe...

Страница 6: ...Motic microscope repair agency to have it repaired Please be sure to turn off the power before opening the instrument to replace LED illuminator or replace the fuse Only use a fuse for the rated curr...

Страница 7: ...7 2 1 General Views 2 INSTRUMENT DESCRIPTION RED39Z...

Страница 8: ...1 Eyepiece 6 Base 2 Binocular tube 7 Handle 3 Objective turret 8 Focus knob 4 Sample clip holder 5 Stage plate 9 Brightness adjustment knob incident illumination 10 Brightness adjustment knob transmit...

Страница 9: ...king distance 47mm 68mm Built in Rechargeable Battery N Y Y Illumination Incident and Transmitted LED illumination Optional Objectives Objectives 1X 3X 4X All of the models in the RED30 Series stereo...

Страница 10: ...of the eyepieces and other optical components do not touch the lens surface Make sure the lock screws of the eyepieces are adjusted correctly The eyepieces should turn easily but should not be able to...

Страница 11: ...ent LED brightness at the right hand of the base Figure 3a Control the transmitted LED brightness at the left hand of the base Figure 3b After use turn the brightness control to the minimum position a...

Страница 12: ...models Observe with the right eyepiece only and rotate the focus knob until the image is in focus Observe with the left eyepiece and adjust the diopter ring on the left body tube until a focused imag...

Страница 13: ...aining ring from the LED array and then unplug remove and finally replace the LED array When replacing the Incident illumination for RED39Z first remove the turret cover glass and the ring and then Sl...

Страница 14: ...ents the eyepiece from falling out The diopter ring is located on the left body tube Please refer to the Section 3 2 2 of the Operation Instructions for the correct method of adjustment 4 2 Stand The...

Страница 15: ...place with the spare fuse or contact your local distributor Check if the illuminator is burnt out if yes replace the illuminator or contact your local distributor Check if the supply voltage is the sa...

Страница 16: ...rature Permissible relative humidity 10 40 C Below 31 C max humidity is 80 at 40 C linearly decreases to 50 Operation Permissible environment temperature Permissible relative humidity 5 40 C Below 31...

Страница 17: ...cus adjustment mechanism Coarse focus adjustment Stroke 19 8mm rotation 47mm Objective RED30S RED39Z Paired 2X and 4X 1X 3X Eyepiece Field number 20mm Assembly diameter 30mm W10X 20 In the registered...

Страница 18: ......

Страница 19: ......

Страница 20: ...ouse 311 Gloucester Road Causeway Bay Hong Kong Tel 852 2837 0888 Fax 852 2882 2792 Motic Spain S L U Spain Pol Ind Les Corts C Les Corts 12 08349 Cabrera de Mar Barcelona Spain Tel 34 93 756 6286 Fax...

Отзывы: