5. Requirements for compressed air supply
•
recommended compressed air pressure 5.0 to 8.5 bar.
•
approx. air consumption <300 l/min.
•
compressed air must be dry and clean.
•
compressed air minimum temperature: 3°C.
•
maximum oil content is 0.1 mg/m3.
•
maximum particle size in the air: 15 microns.
•
compressor tank minimum size: 100 litres.
•
do not use oil-lubricated air. It may damage the plasma torch.
ATTENTION!
It is recommended to use an additional air dryer at the device inlet, e.g. AT-1000. Complaints on quick
parts wears or short circuit in plasma cutter torch, where no additional air dryer was installed will be
considered negatively.
Accessories available:
Figure 1: AT-1000 filter and the way of fixing it to the device gas quick coupling.
1
AT-1000 air filter with fixing
617610 5302
2
Paper insert for AT-100
617610 5303
3
AT-1000 filter adaptor (Inlet-outlet fittings)
617610 5304
Accessories available for ordering in each
RYWAL-RHC
branch (see page 24)
Table 2: MasterCut 120 CNC MOST. Accessories available.
ATTENTION!
Using of improperly cleaned or moist air will result in shorter service life of parts or may damage the torch.