Installation
2-10
602-95555-01 Rev A
NXE1-20 Digital Radio
2.9.2
Hot Standby Control using the Moseley TP64
2.9.2.1 TP64 Front Panel Controls and Indicators
Note:
See the following section for a detailed description of the Master/Slave logic implemented
in the TP64.
Figure 2-7. TP64 Front Panel
LED Indicators
Green:
The indicated module is active, and that the module is performing within
its specified limits.
Yellow:
The indicated module is in standby mode, ready and able for back-up
transfer.
Red:
There is a fault with the corresponding module. It is not ready for
backup, and the TP64 will not transfer to that module.
TRANSFER Switches
The RADIO A and RADIO B transfer switches cause the selected radio to become
active
, and the
Master
. See Section 3.4 (following) for further details.
2.9.2.2
Master/Slave Operation & LED Status
The TP64 operates in a Master/Slave logic mode. In the power up condition, the Master is
RADIO A. This means that RADIO A is the default active unit. The following logic applies to hot
or cold standby, external or internal duplexer configurations.
Содержание NXE1-20