CALIBRATION
8
The module is calibrated at the factory. This should only be necessary if you have a specific need
to recalibrate (for example, dealing with a different format like Buchla, or an oscillator that doesn’t
track accurate 1V/octave) To enter calibration mode, hold the shift button while powering up the
module. You’ll see the first LED begin to pulsate.
If you accidentally enter this mode, you can restart your system without losing any previous calibra-
tion data.
After tuning your oscillator to a known note or frequency (e.g. A (110Hz)) and patching Quantiz-
er’s CV out to the oscillator’s v/oct input, use the SCALE buttons (and the SLEW buttons if neces-
sary) to trim each octave to be at the same note, one octave apart each. Use the OCTAVE buttons
to move up and down octaves, and fine tune until each octave is accurately calibrated (For the
above example, the octaves would be 220Hz, 440Hz, 880Hz, etc.)
The SCALE buttons are a fine tune, while the SLEW buttons move the notes 10 times as far.
If things get really out of wack, press the load button ( ) to reload the default values.
When you’re satisfied that the octaves are accurate, press the Save button ( ) to store this data,
and exit calibration mode.