Page 12 of 1
5
WARNING:
For your safety, read and follow the Lighting Instructions in this manual and in the Rating
Plate on the appliance. IMPROPER LIGHTING PROCEDURES COULD RESULT IN A FIRE HAZARD
OR EXPLOSION HAZARD OR PROPERTY DAMAGE, INJURY OR LOSS OF LIFE.
TO TURN OFF GAS
1. Push in gas control knob slightly and turn to “OFF”.
Figure 11
Observe Flame Height When Lit:
The burner will display blue and yellow flames. These flames should
be a blue / yellow color between 1~2 in. height (see Figure 12). These flames should not be yellow or
produce thick smoke. This would indicate an obstruction of airflow through the burners. The flames
should be blue with straight yellow tops.
Figure 12
Yellow
Yellow
Light Blue
Light Blue
Blue
Blue
Good
Bad
Operation
LIGHTING INSTRUCTIONS
1. Make sure control knob is in the "OFF" position.
2. Turn LP cylinder gas valve to fully open position.
3. Press down control knob and turn it counter
clockwise to "ON/MIN" position.
4. Push in gas control knob all the way and hold.
Continue to press the ignition button for 15
seconds.
5. If the burner is not lit, press down the control
knob and turn clockwise to "OFF" position,
repeat from step 3 after 5 minutes.
6. When burner is lit, press down the control knob
and turn it to desired heat output position between
"MIN" and "MAX".
7. Press down and turn the control knob clockwise to
"OFF" position to shut down the appliance. Turn off
cylinder gas valve.
ignition button
gas control knob