Mosa GE 4500 HSX Скачать руководство пользователя страница 39

Ricambi

Spare parts

Piéces de rechange

REV.2-07/11

Ersatzteile

Tabla de recambios

GE 4500 HSX

GA

10.1

04/06/04  35455-I

 

Pos.

 

Cod.

 

Descr. 

Note

 

1  M35450A902 

VARIANTE CAVI CHIAVE AVVIAMEN. / STARTING KEY CABLING 

Fino a/Up to REV.0-06/04 - Del 63/11 - 08/06/11

  1  M35456A902 

VARIANTE CAVI CHIAVE AVVIAMEN. / STARTING KEY CABLING 

Da/From REV.1-07/11 - Del 63/11 - 08/06/11

  2  M306479199 

RELE’ AVV. ELETTRICO / RELAY, ELECTRIC START

  3  M270027300 

VOLTMETRO DIGITALE / DIGITAL VOLTMETER 

Vers. 230V

  4  M155307107 

DISGIUNTORE TERMICO / THERMAL SWITCH 

Vers. 230V

  5  M306417036 

GUIDA FISSAGGIO INTERRUTTORE / FIXING GUIDE INTERRUPTOR

  6  M220237105 

Vedi Cod.256007105 / See Part n°256007105

  7  M307017240 

PRESA 220V 16A / EEC SOCKET 16A, 220V 2P+T

  8  M306417318 

PRESA C.B. NERA (-) / BLACK B.C. SOCKET (-)

  9  M306417316 

PRESA C.B. ROSSA (+) / RED BATTERY CHARGER SOCKET (+)

  10  M354507020 

PANNELLO FRONTALE / FRONTAL PANEL 

Vers. 230V

  11  M35450C020 

GR.CAVI MOTORE / ENGINE CABLES 

x connettore EAS - Fino a/Up to REV.0-06/04 - Del 63/11 - 08/06/11

  11  M35456C020 

GR.CAVI MOTORE / ENGINE CABLES 

x connettore EAS - Da/From REV.1-07/11 - Del 63/11 - 08/06/11

  12  M102042740 

CAPPUCCIO / CAP

  13  M107509902 

COMMUTATORE TRIPOLARE / TRIPOLES SWITCH

  14  M101091830 

PULSANTE DI STOP / BUTTON, STOP

  15  M306467109 

PROTEZIONE TERMICA (C.B.) / THERMOPROTECTION (B.C.) 

  16  M103011310 

VOLTMETRO / VOLTMETER  

Vers. 230/110V

  17  M256417315 

COMMUTATORE DI LINEA / COMMUTATOR SWITCH 25A 2P 

Vers. 230/110V

  18  M356317330 

CONTAORE QUADRATO 110V 50Hz / HOURMETER 110V 50HZ  Vers. 230/110V

  19  M105111530 

PRESA CEE 32A 110V / SOCKET, EEC, 32A 110V 

Vers. 230/110V

  20  M354527020 

PANNELLO FRONTALE / FRONT PANEL 

Vers. 230/110V

  22  M259107241 

PRESA SCHUKO / SOCKET SCHUKO 16A 230V 2P+T 

Vers. Schuko

  23  M309509005 

GUARNIZIONE / GASKET 

qm

  24  M354508010 

PANNELLO LATO ASPIRAZIONE / AIR INTAKE PANEL

  25  M744508140 

CERNIERA PER FIANCATA / LATCH

  26  M259102026 

TAPPO SERBATOIO / TANK CAP 

(il tappo originale è fornito con motore)

  27  M354502022 

GUARNIZ. TUBO RIEMP. SERBATOIO / GASKET

  28  M354508015 

PANNELLO LATO MOTORE / COVER, ENGINE SIDE

  29  M354508021 

PORTELLO LATO SCARICO / EXHAUST PANEL 

Fino a/Up to REV.0-06/04 - Del 63/11 - 08/06/11

  29  M354568021 

PORTELLO LATO SCARICO / EXHAUST PANEL 

Da/From REV.1-07/11 - Del 63/11 - 08/06/11

  30  M354508186 

RACCORDO PROLUNGA x TUBO SCAR. / EXHAUST PIPE CONNECTOR

  31  M343339601 

MANIGLIA / KNOB

  32  M354508110 

CHIUSURA A LEVA REGOLABILE / ADJUSTABLE LOCK

  33  M354502310 

SIRINGA SCARICO/CARICO OLIO / OIL FILLING

  34  M354508020 

PANNELLO LATO ALTERNATORE / PLATE ALTERNATOR SIDE

  35  M000035456A730  ASSIEME RELE' / 

RELAY ASSEMBLY 

Da/From REV.1-07/11 - Del 63/11 - 08/06/11

  36  M354567039 

SUPPORTO RELE' / RELAY SUPPORT

 

Da/From REV.1-07/11 - Del 63/11 - 08/06/11

  37  M000035456A725  ASSIEME RESISTORE CABLATO

 / WIRED RESISTOR ASSY 

Da/From REV.1-07/11 - Del 63/11 - 08/06/11

  38  M354569847 

DISSIPATORE / HEAT SINK 

Da/From REV.1-07/11 - Del 63/11 - 08/06/11

  39  M354569895 

RESISTORE CABLATO / WIRED RESISTOR

 

Da/From REV.1-07/11 - Del 63/11 - 08/06/11

Содержание GE 4500 HSX

Страница 1: ...GE 4500 HSX 354559003 GB 0 7 1 1 MOSA 04 06 04 35455M00 preparato da UPT approvato da DITE ENGLISH...

Страница 2: ......

Страница 3: ...or industrial and professional use powered by an endothermic engine it is composed of various main parts such as engine alternator electric and electronic controls the fairing or a protective structur...

Страница 4: ...isfy the needs of its clients aswell as to improve the transparency and thecom munications regarding all the company s activesin accordance with the official procedures and inhar mony with the MOSA Ma...

Страница 5: ...5 INSTALLATION AND ADVICE BEFORE USE M 2 6 INSTALLATION WARNINGS M 2 7 INSTALLATION AND DIMENSIONS M 3 PACKING M 4 1 TRANSPORT AND HANDLING M 25 SET UP FOR OPERATION M 26 START UP M 27 SHUTTING DOWN T...

Страница 6: ...aws in force in the matter In no case MOSA division of B C S S p A will be held responsible for any damaga direct or indirect in relation with the use of the given information MOSA division of B C S S...

Страница 7: ...aces protected from dampness and heat You must take into account that some figures contained in it want only to identify the described parts and therefore might not correspond to the machine in your p...

Страница 8: ...of these directives is part of the declaration of conformity included in any machine standard equipment Here below the adopted symbol CE marking is clearly readable and unerasable and it can be eithe...

Страница 9: ...ola Serial number ______________________________ conforme con quanto previsto dalle Direttive Comunitarie e relative modifiche est en conformit avec ce qui est pr vu par les Directives Communautaires...

Страница 10: ...ds for a yearly number of hours limited at 500 h No overload is admitted Prime power PRP maximum available power for use at variable loads for a yearly illimited number of hours The average power to b...

Страница 11: ...harm to persons or things Do not use without protective devices provided Removing or disabling protective devices on the machine is prohibited Do not use the machine if it is not in good technical co...

Страница 12: ...ersons Use only with safety clothing It is compulsory to use the personal protection means given in equip ment Use only with safety clothing It is compulsory to use the personal protection means given...

Страница 13: ...completely Wipe up spilled fuel before starting engine An electric shock can kill Shut off fuel of tank when moving machine where it is assembled Avoid spilling fuel on hot engine Sparks may cause th...

Страница 14: ...TO RESET START M1 4 900 570 720 230 V Ver s 770 230 110 Ver s SUPER SILENCED CHO KE LOC AL STAR T REMO TE STAR T c c 1 2V 10A CIRCUIT BREAKER PRESS TO RESET STAR T 60 615 440 430 530 GE 4500 HSX M 2 7...

Страница 15: ...so as to cause a dangerous increase of the temperature Make sure that the machine does not move during the work block it possibly with tools and or devices made to this purpose Maximum leaning of the...

Страница 16: ...rough handling or taking away of parts contained inside the packing or in the set In case you find damages rough handling or absence of parts envelopes manuals etc we advise you to inform immediately...

Страница 17: ...th it s packaging and conform to local rules and regulations Only authorized persons involved in the transport of the machine should be in the area of movement DO NOT LOAD OTHER PARTS WHICH CAN MODIFY...

Страница 18: ...ck the oil level AIR FILTER Check that the dry air filter is correctly installed and that there are no leaks around the filter which could lead to infiltrations of non filtered air to the inside of th...

Страница 19: ...ted up Do not use the CHOKE button if the motor is hot or if the ambient temperature is suf ficiently high REMOTE START The unit can also be started by means of the remote TCM control device or throug...

Страница 20: ...e front panel is completely disa bled to stop the generator use the controls on the TCM or EAS panel WARNING NB as a safety measure the start up key must be entrusted to qualified personnel The unit c...

Страница 21: ...carica batteria Batteria Earth terminal A C socket Engine air filter Oil level dipstick Engine oil reservoir cap Fuel tank cap Muffler Oil drain tap Battery charger thermal switch Aux current thermal...

Страница 22: ...the public mains and or another electrical power source Areas for which access by non authorized person nel is forbidden are the control panel at the front the endothermic motor discharge ON OFF PUSH...

Страница 23: ...c c Position the generator and battery on a flat surface and distant from one another Connect the battery recharge cables one at a time avoiding accidental contacts between them Note use cables with a...

Страница 24: ...TCM 15 6 is used it is not possible to connect the E A S automatic intervention unit USE OF THE REMOTE CONTROL TCM 6 The coupling of the TCM 6 with the generating set ready for remot starting permits...

Страница 25: ...F I switch inter vention is due to a faulty ground current in the load or connection cable Find and remove the fault 3 Replace 1 Check total power supplied by generator if greater than the power repo...

Страница 26: ...and troubleshooting work l Stop the engine before doing any work inside the machine If for any reason the machine must be operated while working inside pay attention moving parts hot parts exhaust man...

Страница 27: ...all levels engine oil fuel level battery electrolyte if necessary top it up 3 Control of electrical connections and cleaning of control panel EVERY WEEK NO LOAD X WITH LOAD X X X X X For the electrici...

Страница 28: ...the covers and all the other parts of the machine carefully Protect the machine with a plastic hood and store it in o dry place DIESEL ENGINE For short periods of time it is advisable about every 10...

Страница 29: ...d of the various components of the machine must be made accordingly to rules in force of law a o local rules Particular attention must be paid when getting rid of lubricating oils battery electrolyte...

Страница 30: ...A Generator B Klemmleiste C Kondensatorbox D FI Schalter GFI F Sicherung H Steckdose 230V 1 phasig I Steckdose 110V 1 phasig M Stundenz hler N Voltmeter Q1 Z ndschloss R1 Anlasser S1 Batterie T1 Ladeg...

Страница 31: ...5 M3 11 K1 30 87 87a st 8 5 13 14 13 14 9 9 5 2 6 6 16 16 16 BL W BL W GR GR 11 W K2 85 86 N3 Stop K1 85 86 N3 St 8 5 STARTER KEY OFF ON BAT ST START EXT EXT BL BL W R BL W R ST EXT EXT BAT Q1 BL R Y...

Страница 32: ...Schema elettrico Electric diagram Schemas electriques Stromlaufplan Esquema el ctrico GE 4500 HSX REV 0 06 04 M 61 2 04 06 04 35455 I...

Страница 33: ...Schema elettrico Electric diagram Schemas electriques Stromlaufplan Esquema el ctrico GE 4500 HSX REV 0 06 04 M 61 3 04 06 04 35455 I...

Страница 34: ......

Страница 35: ...ULVERBONDENMETMASSA NEUTROCONECTADOAMASA NEUTRERACCORDEAUBATI NEUTRALBONDEDTOFRAME NEUTROCOLLEGATOAMASSA 65 60 Hz A 10 50 15 55 500 300 V ST RS 0 200 100 TR 0 h HOURMETER I 0 EA 1 25 20 125 1 3 13 18...

Страница 36: ...Ricambi Spare parts Pi ces de rechange REV 2 07 11 E D NL Ersatzteile Tabla de recambios GE 4500 HSX GA 9 04 06 04 35455 I HONDA GX270 5 9 10 12 11 14 1 2 3 1 4 7 8 15 6 13 16...

Страница 37: ...13 M354553036 TIRANTE 14 M306479071 ELETTROMAGNETE COMANDO CHOKE 15 M354553101 STAFFA SUPP ALTERNATORE 16 M354509105 LEVAACCELERATORE Modificata da REV 2 07 11 Del 141 06 05 10 06 Pos Rev Cod Descr No...

Страница 38: ...Ricambi Spare parts Pi ces de rechange REV 1 07 11 Ersatzteile Tabla de recambios GE 4500 HSX GA 10 04 06 04 35455 I SCHUKO VERSION 230V VERSION 230 110V VERSION...

Страница 39: ...I LINEA COMMUTATOR SWITCH 25A 2P Vers 230 110V 18 M356317330 CONTAORE QUADRATO 110V 50Hz HOURMETER 110V 50HZ Vers 230 110V 19 M105111530 PRESA CEE 32A 110V SOCKET EEC 32A 110V Vers 230 110V 20 M354527...

Страница 40: ...Ricambi Spare parts Pi ces de rechange REV 1 09 06 Ersatzteile Tabla de recambios GE 4500 HSX GA 11 04 06 04 35455 I 230 110V VERSION...

Страница 41: ...RE PER PONTE DIODI 14 1270070 PONTE DIODI 120A 15 354551050 BASAMENTO 16 354521170 RUOTA GOMMA PIENA SUPP FISSO 230 110V Version 17 354521099 TRAVERSA SUPP RUOTE 230 110V Version 18 354521270 RUOTA GO...

Страница 42: ...PER SCATOLA TCM TCM COVER 3 102042740 CAPPUCCIO CAP 4 1302040 SPIA 12V WARNING LIGHT 12V 5 102013290 COMMUTATORE COMMUTATOR 6 107302460 STARTER A CHIAVE STARTER KEY 7 33010C060 GRUPPO CAVI TC TC CABL...

Страница 43: ......

Страница 44: ...MOSA div della BCS S p A Stabilimento di Viale Europa 59 20090 Cusago MI Italia Tel 39 0290352 1 Fax 39 0290390466...