![Mosa GE 10000 LD/GS Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/mosa/ge-10000-ld-gs/ge-10000-ld-gs_manual_1836884053.webp)
TROUBLE-SHOOTING
GE
1
0000 LD/GS
GE
1
2000 LD/GS
M
40.2
REV.0-10/10
The motor does not start up, or
starts up and then stops imme-
diately
1) Lack of fuel in tank or fuel tap closed
2) Fuel filter clogged
3) Air leaks in fuel system
4) Battery not activated, low or faulty
5) Battery cable terminals loose or corroded
6) Other causes
1) Refill the tank. Open the fuel tap
2) Replace
3) Check the feeding circuit
4) Activate, recharge, or replace the battery
5) Tighten and clean. Replace if corroded.
6) Consult the motor Operating Manual.
Problem
Possible cause
Solution
ENGINE
1) Air or fuel filter clogged
2) Overload
1) Clean or replace filter element(s).
Refer to engine manual
2) Check the connected loads and if recessary reduce
The motor does not accelerate.
Inconstant speed.
Too little power provided by
motor.
Other problems or inconvenien-
ces on the engine
Consult the motor Operating Manual.
14/10/10 25940-GB
WARNING
!
●
Have
qualified
personnel do maintenance and troubleshooting work.
● Stop the engine before doing any work inside the machine. If for any reason the machine must be operated while working inside,
pay
attention
moving parts, hot parts (exhaust manifold and muffler, etc.) electrical parts which may be unprotected when the machine is
open.
● Remove guards only when necessary to perform maintenance, and replace them when the maintenance requiring their removal is com
-
plete.
● Use suitable tools and clothes
● Do not modify the components if not authorized.
- See pag. M1.1 -
GENERATOR
1) Protection tripped due to overload
2) Differential protection device tripped
3) Protection devices defective
4) Alternator not sparked
5) Alternator defective
1) Check the load connected and diminish
2) Check on the entire installation: cables, connections,
utilities connected have no defective sheathing which
may cause incorrect currents to ground
3) Replace
4) Carry out external spark test as indicated in alternator
manual. Ask for intervention of Service Department
5) Check winding, diodes, etc. on alternator (Refer to
alternator manual). Repair or replace.
Ask for intervention of Service Department
1) Check position of accelerator lever.
Regulate speed to its nominal no-load value
2) Check winding, diodes, etc. on alternator (Refer to
alternator manual). Repair or replace.
Ask for intervention of Service Department
1) Check the load connected and diminish
2) Reduce or rephase load
3) Check winding, diodes, etc. on alternator (Refer to
alternator manual). Repair or replace.
Ask for intervention of Service Department
1) Check electrical connections and tighten
2) Ask for intervention of Service Department
3) Check winding, diodes, etc. on alternator (Refer to
alternator manual). Repair or replace.
Ask for intervention of Service Department
Corrected no-load voltage too
low with load
1) Incorrect motor running speed
2) Alternator defective
1) Incorrect motor running speed due to over-
load
2) Load with cos
ϕ
less than the nominal one.
3) Alternator defective
Absence of output voltage
No-load voltage too low or too
high
1) Contacts malfunctioning
2) Irregular rotation of motor
3) Alternator defective
Unstable tension
Содержание GE 10000 LD/GS
Страница 21: ...Comandi Controls Commandes GE 10000 LD GS GE 12000 LD GS M 31 REV 0 10 10 14 10 10 25940 I...
Страница 49: ...Comandi Controls Commandes GE 10000 LD GS GE 12000 LD GS M 31 REV 0 10 10 14 10 10 25940 I...
Страница 77: ...Comandi Controls Commandes GE 10000 LD GS GE 12000 LD GS M 31 REV 0 10 10 14 10 10 25940 I...
Страница 105: ...Comandi Controls Commandes GE 10000 LD GS GE 12000 LD GS M 31 REV 0 10 10 14 10 10 25940 I...
Страница 112: ......
Страница 133: ...Comandi Controls Commandes GE 10000 LD GS GE 12000 LD GS M 31 REV 0 10 10 14 10 10 25940 I...
Страница 141: ...M 56 MOSA 1 0 04 04 08 04 04 M56 DIMENSIONI DIMENSIONS SCHEMI ELETTRICI ELECTRICAL SYSTEM RICAMBI SPARE PARTS...
Страница 144: ...14 10 10 25940 I Schema elettrico Electric diagram Schemas electriques GE 10000 LD GS GE 12000 LD GS M 61 1 REV 0 10 10...